TU8325 B&C Electronics Submersible Turbidity Sensor

TU8325 submersible turbidity probe with compressed air self-cleaning, 4…20 mA output, RS485 and Modbus RTU for drinking water and water treatment.

He submersible turbidity sensor TU8325 from B&C Electronics this Designed for continuous measurement of low turbidity in drinking water, water treatment, and industrial processes. Measurement is performed using the nephelometric method in accordance with applicable standards. ISO 7027 and EN 27027, using infrared light and 90° scattered light detection.

Unlike in-line turbidity probes, the TU8325 It is specially designed for submerged applications in reservoirs, channels, tanks, measuring chambers or installations where direct measurement of the process liquid is required.

The probe incorporates a system of self-cleaning using compressed air, It consists of an integrated nozzle that directs a jet of air onto the sensor's optical area. This system helps reduce the accumulation of scale, solids, and organic deposits on the lenses, improving measurement stability in continuous monitoring applications.

The TU8325 allows you to select different turbidity scales up to 400 NTU, with a resolution of up to 0.001 NTU in the low range. Infrared measurement minimizes the influence of sample color, providing stable and repeatable readings in low turbidity applications.

The sensor has isolated analog output 4…20 mA and digital communication RS485 through protocols Modbus RTU and B&C ASCII, facilitating its integration into PLCs, SCADA systems, data loggers, and industrial monitoring systems.

In addition to turbidity measurement, the probe incorporates internal temperature compensation and self-diagnostic functions via an optical verification signal. This function allows monitoring of the lens condition and detection of issues such as fouling, dry cell, lack of contact with the sample, or excessive external light.

He TU8325 It is suitable for drinking water applications, ETAP, WWTP, industrial water treatment, filtration control, process tanks and continuous monitoring systems where a robust, submersible and self-cleaning probe is required.

For proper installation, the probe should ideally be submerged at an angle that facilitates the cleansing action of the rising air. The system requires clean air at a maximum pressure of 3 bar. The typical cleaning time is approximately 15 seconds, with an indicative frequency of two cycles per day, although these values depend on the application and the solids load of the process.

Thanks to her body in PVC, protection IP68, thread 2″ NPT With its industrial design for continuous operation, the TU8325 is a robust solution for submersible turbidity measurement in water installations and industrial processes.

Properties

ModelTU8325
ManufacturerB&C Electronics
Type of equipmentSubmersible turbidity probe with self-cleaning
Measurement principleNephelometric method using light diffusion at 90°
RegulationsISO 7027 / EN 27027
Main applicationContinuous turbidity measurement in reservoirs, channels and submerged processes
ApplicationsDrinking water, water treatment plants, wastewater treatment plants, water treatment, filtration and water quality monitoring
Configurable ranges0.000…4.000 NTU / 0.00…40.00 NTU / 0.0…400.0 NTU
Resolution0.001 NTU / 0.01 NTU / 0.1 NTU depending on the selected scale
Measurement cycle2 seconds
Light sourceInfrared LED
DetectorPhotodiode for turbidity measurement and photodiode for verification signal
Analog output4…20 mA galvanically isolated
Digital communicationRS485 with Modbus RTU and B&C ASCII protocol
Modbus functions03, 06 and 16
Communication speed2400 / 4800 / 9600 / 19200 baud
Digital filterConfigurable response time from 2…220 s
Temperature compensationBuilt-in RTD Pt100 sensor
Optical diagnosisVerification signal for detecting dirt, dry cell, or high external light
Feeding9…36 Vcc
ProtectionIP68
Body materialPVC
Operating temperature-5…+50 °C
Operating pressure0…6 bar at 25 °C / 0…3 bar at 50 °C
Diameter60 mm
Length165 mm
Thread2″ NPT
Self-cleaningBuilt-in nozzle for compressed air
Air connection1/4″ internal, 3/8″ external
Cleaning air pressure3 bar, maximum 10 seconds per cycle
Wire5 x 0.25 mm², length 10 m, PVC coating
Weight420g body + 640g cable
Compatible accessoriesAdapter 0012.450043, swivel mount 0012.000624 and PVC pipe 0012.440040

Other products

B&C ELECTRONICS Logo 2026 WATER QUALITY
Graphite Sensor with built-in PT-100, 3m Cable, K=1 cm⁻1 Range from 2MicroSiemens to 2,000 milliSiemens,
B&C ELECTRONICS Logo 2026 WATER QUALITY
Combined glass/gel pH reference electrode, epoxy body. 9m cable
B&C ELECTRONICS Logo 2026 WATER QUALITY
pH probe for immersion in PVC tube. Length 1170 mm.
B&C ELECTRONICS Logo 2026 WATER QUALITY
PH sensor for range 0 to 13pH with 9m cable Compatible with all controllers on the market
B&C ELECTRONICS Logo 2026 WATER QUALITY
Measuring range 0-4,000/40,00/400,0/4,000NTU
B&C ELECTRONICS Logo 2026 WATER QUALITY
Self-cleaning turbidimeter, Measuring range 0-4,000/40,00/400,0/4,000 NTU
B&C ELECTRONICS Logo 2026 WATER QUALITY
Antimony combined reference pH electrode with epoxy body, size 75x12. with 9m cable for the galvanic industry.
B&C ELECTRONICS Logo 2026 WATER QUALITY
Conductivity range from 4 to 2,000 mS/cm and TDS (total dissolved solids) from 10ppt to 1,000ppt 4…20mA and Modbus output
B&C ELECTRONICS Logo 2026 WATER QUALITY
Graphite Sensor, 1.5m Cable with BNC connector, K=1cm Range from 2MicroSiemens to 2,000 milliSiemens,
B&C ELECTRONICS Logo 2026 WATER QUALITY
pH sensor for range 0 to 13pH with BNC connector Compatible with all controllers on the market
Shopping Basket