B&C Electronics Liquid Analyzers: Controllers and Sensors

B&C Electronics Liquid Analyzers: Controllers and Sensors

Catalog · B&C Electronics

pH-ORPConductivity-TDSDissolved oxygenTurbidity 4,000 to 4000 NTUProbes up to 350 m
Quick responseThe 13-page B&C Electronics catalog covers liquid analyzers for pH-ORP, conductivity-TDS, dissolved oxygen, turbidity-TSS, nitrates, chlorine, chlorine dioxide, ozone, hydrogen peroxide-PAA, ammonia, and sulfite-sulfide. It includes panel, wall, and DIN rail controllers (6587, 7685, 7635, 3436, 7335, 7687 series), 3630 transmitters, the 135 handheld meter, UV probes, and 8000 multiparameter probes (up to 350 meters depth) and sensors for pH, conductivity, turbidity, chlorine and dissolved oxygen.

Parameters and applications

  • pH – ORP
  • Conductivity – TDS
  • Dissolved oxygen, including optical fluorescence control
  • Turbidity – TSS
  • Nitrates – SAC – free UV spectrometry
  • Combined residual chlorine
  • Total chlorine in gas phase
  • Chlorine dioxide
  • Dissolved ozone
  • Hydrogen peroxide – PAA
  • Dissolved ammonia
  • Sulfite – dissolved sulfide

Applications cited: water treatment and purification, drinking water treatment, aquaculture, biotechnology, chemical industry, electroplating, environmental monitoring, fertigation, food industry, geology, laboratory, pulp and paper, pharmaceutical industry, detection and security, graphic arts, surface treatment, swimming pools, textile industry, groundwater monitoring, and research and development. OEM and customized versions are available.

Controllers and transmitters

RangeFacilityParametersFeedingDimensions
6587Wall mountable, IP 65; ABS enclosure with polycarbonate front panelpH – ORP – conductivity – temperature – residual chlorine – dissolved ozone – chlorine dioxide; up to 3 analog sensor inputs or 4…20 mA probes85 – 264 Vac; optional 9-36 Vdc or 24 Vac256 x 213 x 74 mm
768596x96 PanelpH – ORP – conductivity – dissolved oxygen – residual chlorine – dissolved ozone – chlorine dioxide – turbidity – dissolved sulfite/sulfide110/220 Vac96 x 96 x 155 mm
763596x96 panel; 95mm deep aluminum casing; red LED displaypH – ORP – conductivity – dissolved oxygen – residual chlorine – dissolved ozone; signal inputs ±4…20 mA85 – 264 Vac; optional 9 – 36 Vdc or 24 Vac96 x 96 x 95 mm
3436DIN rail; alphanumeric LCD display; block-removable terminalspH – ORP – conductivity – temperature – residual chlorine – dissolved ozone; automatic or manual RTD Pt100 temperature compensation9 – 36 Vdc71 x 95 x 58 mm (4 modules)
733596×48 panel; 95 mm deep aluminum casing; red LED displaypH – ORP – conductivity – dissolved oxygen – residual chlorine – dissolved ozone; signal inputs ±4…20 mA85 – 264 Vac; optional 9 – 36 Vdc or 24 Vac96 x 48 x 95 mm
7687Panel, IP 65; water-resistant keypad; aluminum housingpH – ORP – conductivity – dissolved oxygen – residual chlorine – dissolved ozone – chlorine dioxide – turbidity – dissolved sulfite/sulfide; inputs ±4…20 mA85 – 264 Vac; optional 9 – 36 Vdc or 24 Vac96 x 96 x 95 mm
3630 (transmitter)DIN rail; two wires 4…20 mA; closed-loop isolated output; RTD Pt100 temperature compensation; LCD displaypH – ORP – conductivity – dissolved oxygen – residual chlorine – dissolved ozone10 – 30 Vdc105 x 95 x 58 mm (6 modules); 200 g
RangeFunctions and outputs
6587Integrated data logger and USB port; backlit graphic display; RS 485 communication; two selectable On-Off relays, PID (PWM-PFM) functions; high or low value alarm relay and delay; adjustable self-cleaning relay; dual programmable 0/4…20 mA analog output
7685Two selectable On-Off relays, PWM-PFM functions; high or low value alarm relay with delay; self-cleaning relay; dual programmable 0/4…20 mA analog output
7635 and 7335Two selectable On-Off relays; alarm relay with adjustable high-low values and delay; sliding short messages on screen
3436Isolated 4…20 mA analog output; isolated RS 485 ASCII Modbus digital output; 1000 V input-to-output isolation
7687Integrated data logger and USB port; backlit graphic display; RS 485; two On-Off relays, PID functions (PWM-PFM); alarm relay; self-cleaning relay; dual programmable 0/4…20 mA analog output
3630500V input-to-output isolation; block-removable terminals
6587 series controller for wall mounting
6587 series controller for wall mounting
7687 Series Controller for Panel
7687 Series Controller for Panel

Portable meters and online analyzers

The 135 range portable meter is a system with a microprocessor, long battery life, alphanumeric LCD display and recording of up to 100 measurements.

Gamma 135: parameterRange
pH-1,00 / 15,00
ORP-1200 / 1200 mV
Conductivity (5 selectable scales)20.00; 200.0; 2000 µS; 20.00; 200.0mS
TDS (5 selectable scales)10.00; 100.0; 1000ppm; 10.00; 100.0 ppt
Temperature-10.0 / 110.0 °C and 32.0 / 212.0 °F
Portable meter from the 135 range
Portable meter from the 135 range

Online chemical analysis module analyzers (ISE and polarographic), designed for the 7685 and 7687 series controllers, with gas-phase, ion-specific, and polarographic membrane analyzers, and Auto Cal functions for the ISE analyzers. 110/220 Vac power supply.

ExtentScales
Total chlorine, gas phase2,000 / 20,00 ppm Cl2
Total chlorine, liquid phase, iodometric2,000 / 20,00 / 200,0 ppm Cl2
Sulfite/sulfide, gas phase2,000 / 20,00 ppm SO3- / S2-
ISE-specific electrodesNO3- / NH4+ / Cl- / F- / Ca2+ / Ca2+ Mg2+

UV, digital and multiparameter probes

ProductCharacteristicsTechnical data
UV probes for nitrate, nitric nitrogen and SACWideband spectrometric analyzer; isolated 4…20 mA and RS 485 output; self-cleaning optical path; automatic sampling turbidity and organic matter compensationScales (NO2-) (NO3-) – N: 2.50 / 25.0 / 250 mg/l; NO3- scales: 10.00 / 100.0 / 1,000 mg/l; sensitivity 0.01 mg/l; power supply 11 – 36 Vdc
Digital-analog probesIsolated 4…20 mA and RS 485 output; all-in-one devices; configuration via RS 485 / USB interface; immersion with self-cleaning or on pipe, with fixed cable or 7-pin DL connectorParameters: conductivity (analog only), turbidity, suspended solids, dissolved oxygen (optical); power supply 9 – 36 Vdc; length 165 mm; diameter 60 mm; standard cable 10 m (max. 100 m)
Multiparameter probes, 8000 rangeContinuous monitoring; models with internal data logging and rechargeable batteries; OEM models for external loggers; ASCII digital communication or Modbus protocol; depth limit up to 350 metersStandard: level, temperature, conductivity, pH, ORP, dissolved oxygen (optical or polarographic); optional: turbidity, chlorine ISE, ammonium ISE, nitrate ISE; internal power supply 2.7 – 4.8 Vdc or external 12 Vdc, max. 60 mA; length 510 mm, diameter 70 mm or 44.5 mm; max. weight 2 kg

pH, conductivity, turbidity, chlorine and dissolved oxygen sensors

SensorConstruction and technical data
pH/ORP/ISEBody in glass or epoxy; gel type with double annular joint reference; temperature from -20 °C to 125 °C; sterilizable by steam or autoclave; standard length 110 mm and diameter 12 mm; fixed cable of 1.5 m with BNC or 9 m without connector; detachable DL / S7 / S8 (PG 13.5) connections; pressure up to 10 Bar for pipe insertion
Conductivity of two and four electrodesBody in PVC, PP, PVDF, PEEK, PES and stainless steel; models up to 125 °C; cell constant K from 0.01 to 10 cm-1; built-in RTDs Pt 100 / Pt 1000 / NTC 10K; fixed 1.5 m cable with BNC or 9 m without connector; threaded connection ½” – 1” BSP – ½” BSP – ¾” MNPT, tapered DIN 11851-52 or sanitary triple clamp 2”
Toroidal conductivityPVC-C and PVDF body; built-in 4…20 mA 2-wire transmitter; K = 1 cm-1 with local amplifier or K = 7 cm-1 without amplifier; Pt 100 RTD; 1 ½” MNPT BSP threaded connection for DN40 pipe or DIN 11851-52 tapered connection; designs for multi-position control in cooling towers
Turbidity-SSSelf-cleaning nephelometric method; PVC and PVDF body; 4,000 / 40,000 / 400,000 / 4,000 NTU scales; infrared (ISO 7027) or solid-state tungsten (USEPA 180.1) optical source; empty cell or dirty lens diagnostics; self-cleaning with external compressed air, max. 3 BAR; 10 m or 30 m cable (optional up to 100 m); 7-pin in-line DL connector
Cl2 / ClO2 / DO3 / H2O2Potentiostatic and polarographic; body in glass, epoxy, or PVDF; free residual chlorine and combined residual chlorine; Pt100 RTD; 3 m encapsulated cable without connector or 7.5 m detachable cable; potentiostatic cell 110 mm long and 12 mm in diameter; polarographic cell 60 mm and 33 mm (wet part)
Dissolved oxygenOptical (fluorescence quenching), with galvanic or polarographic membrane, with self-cleaning; PVC or PVDF body; Pt100 RTD; self-cleaning with external compressed air, max. 3 BAR; 10 m encapsulated cable without connector (optional up to 100 m) or 7.5 m detachable cable; replaceable membranes and sensor elements
Sensor in flow assembly (page 12 of the catalog)
Sensor in flow assembly (page 12 of the catalog)

Company and certification

FactWorth
Foundation1974, to manufacture water analysis equipment and industrial process control
CertificationISO 9001 in 1998, by CISQ-IQNET
Quality modelTotal Quality and the EFQM model
Product testingAll products are tested and calibrated at the factory before shipment
PresenceLocal distributors and customers in major countries across 5 continents

Frequently Asked Questions

What parameters do B&C Electronics analyzers measure?

pH-ORP, conductivity-TDS, dissolved oxygen, turbidity-TSS, nitrates-SAC, residual and total chlorine, chlorine dioxide, dissolved ozone, hydrogen peroxide-PAA, ammonia and sulfite-sulfide.

What ranges of controllers does the catalog include?

6587 wall mount, 7685, 7635 and 7687 96×96 panel mount, 7335 96×48 panel mount and 3436 DIN rail mount, plus the 3630 DIN rail transmitter.

What turbidity scales does the Turbidity-SS sensor have?

4,000 / 40,00 / 400,0 / 4000 NTU, with infrared (ISO 7027) or solid-state tungsten (USEPA180.1) source.

How deep can the 8000 series multiparameter probes reach?

Up to 350 meters, with ASCII digital communication or Modbus protocol.

What pH range does the 135 series portable meter measure?

From -1.00 to 15.00 pH, with ORP from -1200 to 1200 mV and temperature from -10.0 to 110.0 °C.

What power supply do the 7687 controllers require?

85 – 264 Vac, with option of 9 – 36 Vdc or 24 Vac.