Measurement
- Nephelometric method ISO 7027 using 90° light diffusion. Standards: ISO 7027 / EN 27027.
- Pulsed infrared light source.
- Configurable ranges: 0…4,000 / 0…40,00 / 0…400,0 NTU.
- Resolution: 0.001 NTU.
- Accuracy: 0.2% of selected full scale. Repeatability: 0.1%. Nonlinearity: 0.1%. Zero stability: ±0,400 NTU.
- Configurable digital filter with dual time constant (2…220 s). Integrated temperature compensation.
- Optical diagnostics using «check signal»: monitoring of the sensor's optical status, optical contamination, and absence of sample.
Signals and communication
- Analog output 4…20 mA galvanically isolated. Maximum load: 600 Ω at 24 VDC.
- Isolated RS485 digital communication with Modbus RTU (functions 03, 06 and 16) and B&C ASCII.
- Communication speed: 2400 / 4800 / 9600 / 19200 baud.
- EMC/RFI Compliance: EN 61326-2-3:2013 / EN 55011:2009.
- Integration into PLC, SCADA and data acquisition systems.
Mechanical and environmental data
- Power supply: 9…36 Vdc.
- PVC-C body. TU8525.5 version in PVDF. IP68 protection.
- Operating temperature: max. 60 °C. Maximum pressure: 6 bar at 25 °C.
- Dimensions: 143 mm in length × 40 mm in diameter. Weight: 160 g for the body and 640 g for the cable.
- Cable: 10 m standard, maximum 100 m.
Installation and accessories
Inline, overflow, or tank installation. Compatible accessories: TU910 and TU920 cells, YAT75M0021 adapter, and SZ7521 bracket.
- Online: via adapters and bypass. For industrial bypass, use Tee type adapter YAT75M0021.
- In storage: using specific accessories.
- In overflow: cells TU910 and TU920.
- Low turbidity: TU910 overflow cell, which stabilizes the sample, regulates the flow rate and reduces air microbubbles.
- Higher turbidity or higher sample flow rate: TU920 cell.
Applications: water quality control, drinking water, water treatment plants and wastewater treatment plants, filtration control and industrial automation.
Properties
| Model | TU8525 |
| Manufacturer | B&C Electronics |
| Type of equipment | Industrial turbidity probe for water and processes |
| Measurement principle | Nephelometric method ISO 7027 using light diffusion at 90° |
| Regulations | ISO 7027 / EN 27027 |
| Main application | Continuous measurement of low turbidity in drinking water and industrial processes |
| Applications | Drinking water, water treatment plant, water treatment and filtration control |
| Industrial integration | PLC, SCADA and data acquisition systems |
| Configurable ranges | 0…4.000 / 0…40.00 / 0…400.0 NTU |
| Resolution | 0.001 NTU |
| Precision | 0.2 % of the selected full scale |
| Repeatability | 0,1 % |
| Nonlinearity | 0,1 % |
| Zero stability | ±0.400 NTU |
| Analog output | 4…20 mA galvanically isolated |
| Digital communication | Isolated RS485 with Modbus RTU |
| Protocols | Modbus RTU (functions 03, 06 and 16) and B&C ASCII |
| Communication speed | 2400 / 4800 / 9600 / 19200 baud |
| Digital filter | Configurable digital filter with double time constant (2…220 s) |
| Temperature compensation | Integrated |
| Optical diagnosis | Check signal for monitoring the sensor's optical status |
| Feeding | 9…36 Vcc |
| Maximum load | 600 Ω at 24 VDC |
| Working temperature | Max. 60 °C |
| Maximum pressure | 6 bar at 25 °C |
| Body material | PVC-C |
| Available version | Version TU8525.5 available in PVDF |
| Protection | IP68 |
| Cable length | 10 m standard, maximum 100 m |
| Dimensions | 143mm length × 40mm diameter |
| Weight | 160g body + 640g cable |
| Facility | In-line installation, overflow or tank |
| Compatible accessories | TU910 / TU920 cells, YAT75M0021 adapter and SZ7521 bracket |
| EMC/RFI Compliance | EN 61326-2-3:2013 / EN 55011:2009 |


Related documentation, cases, and guides
Other products

Combined glass/gel pH reference electrode, with 1.5m cable and BNC connector, double ceramic junction for high temperature

CAN SAE J1939 | Ø 48 mm | 14-bit resolution | Shaftless: magnetic placeholder | 12/24 VDC (8 … 34 VDC) | IP67 / IP68 / IP69 | 1 or 2 channels

Triple output: RMS speed 0-10 V + g surround 0-10 V + acceleration AC 100 mV/g | +15 to +24 V DC @ 10 mA | -25 °C to +90 °C | Shielded PVC cable

OEM position transmitter for HP/LP bypass valves, turbine control valves, and steam conditioning systems

4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67 | Group I (mining)

SPI, TTL level | Ø 28 mm | 14-bit resolution | Ø 6 mm spindle or push-in coupling | 5 VDC (4.5 … 5.5 VDC) | IP54 / IP65 / IP67

Housing Ø63 mm, square flange | Shaft Ø9.52 h7 stainless steel | 1 to 25000 imp/rev | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP65 shaft (IP66 sealed) | 100 kHz (300 kHz optional)

Magnetostrictive, non-contact | Voltage or 4…20 mA output | Stroke 50…2000 mm | Linearity ≤ ±0.04 % FS (min. 300 µm) | Resolution ≤ 0.1 mm | 12/24 VDC or 24 VDC | 350 bar · IP67

Hollow shaft Ø4, 6 or 8 mm H7 | Housing Ø38 mm | 1 to 2540 imp/rev | NPN, PNP, push-pull, line driver | Power supply 5–30 V | IP65 shaft (IP66 Z-seal) | Tangential coupling