NESA order references
Order references for NESA sensors and equipment (166 references for 61 products). Each reference links to its corresponding product data sheet line, with its configuration. Guemisa is an official NESA distributor in Spain. If you cannot find your product, please email us at ventas@guemisa.com with the label code and we will identify it.
| Reference | Configuration |
|---|
| ALB-NALBN | Model: ALB · Output signal: Dual natural µV output · Supply: With calibration report |
| Reference | Configuration |
|---|
| VV1-AVV1A | Model: VV1 · Heating: Standard · Output signal: 0÷2Vdc |
| VV1-BVV1B | Model: VV1 · Heating: Standard · Output signal: 4÷20mA |
| VV1-CVV1C | Model: VV1 · Heating: Standard · Output signal: RS485/Modbus (Standard ID 009) |
| VV1-NVV1N | Model: VV1 · Heating: Standard · Output Signal: Frequency 0÷150Hz or 0÷300Hz |
| VV1R-AVV1RA | Model: VV1R · Heating: Heated (Pw<5W) · Output signal: 0÷2Vdc |
| VV1R-BVV1RB | Model: VV1R · Heating: Heated (Pw<5W) · Output signal: 4÷20mA |
| VV1R-CVV1RC | Model: VV1R · Heating: Heated (Pw<5W) · Output signal: RS485/Modbus (Standard ID 009) |
| VV1R-NVV1RN | Model: VV1R · Heating: Heated (Pw<5W) · Output signal: Frequency 0÷150Hz or 0÷300Hz |
| Reference | Configuration |
|---|
| ANESTANEST | Technical description: Static triaxial sonic anemometer for wind speed and direction, UVW Cartesian components and sonic temperature. Output: RS485 or analog channels; with calibration report |
| Reference | Configuration |
|---|
| ANESB-BANESBB | Model: ANESB · Heating: Not heated · Output signal: Dual 4÷20mA output (speed and direction) |
| ANESB-CANESBC | Model: ANESB · Heating: Not heated · Output signal: RS485/Modbus |
| ANESBR-BANESBRB | Model: ANESBR · Heating: Heated (10W) · Output signal: Dual 4÷20mA output (speed and direction) |
| ANESBR-CANESBRC | Model: ANESBR · Heating: Heated (10W) · Output signal: RS485/Modbus |
| Reference | Configuration |
|---|
| ANESRANESR | Model: ANESR · Speed and direction range: 0 ÷ 50 m/s · 0 ÷ 360° · Output signal: 2 x 4÷20mA, with calibration report |
| Reference | Configuration |
|---|
| BAR-AVBARAV | Transducers: 1 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable |
| BAR-AV-SBARAVS | Transducers: 3 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable |
| Reference | Configuration |
|---|
| SSUSSU | Description: Support arm, length 700/750 mm, with Ø 40 mm clamping jaws for sensors and fixing to posts of max. Ø 60 mm. Stainless steel screws |
| Reference | Configuration |
|---|
| CS05CS05 | Description: Shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 5 m |
| CS05-SCS05S | Description: Custom shielded sensor-datalogger cable, with ferrules on the datalogger side and a connector on the sensor side. Length: 5 m |
| CS05RCS05R | Description: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 5 m |
| CS10CS10 | Description: Shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 10 m |
| CS10-SCS10S | Description: Custom shielded sensor-datalogger cable, with ferrules on the datalogger side and a connector on the sensor side. Length: 10 m |
| CS10RCS10R | Description: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 10 m |
| CSxxCSxx | Description: Shielded sensor-datalogger cable, with PS/2 connector or ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length xx m |
| CSxx-SCSxxS | Description: Custom shielded sensor-datalogger cable, with PS/2 connector or ferrules on the datalogger side and a connector on the sensor side. Length xx m |
| CSxxRCSxxR | Description: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length xx m |
| Reference | Configuration |
|---|
| Evolution-MEvolutionM | Description: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD. |
| Reference | Configuration |
|---|
| EvolutionEvolution | Description: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD, DIN rail mount. |
| Reference | Configuration |
|---|
| DISDIS | Output: RS485 · Supply: With 10m cable included |
| Reference | Configuration |
|---|
| SFL.Lora-PSFLLoraP | Description: Wireless acquisition and transmission interface for IoT LoRa/LoRaWAN platform, 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission every 15 minutes directly to the cloud, accessible via browser or app. |
| SFL.NESA-PSFLNESAP | Description: Wireless acquisition and transmission interface with NESA protocol – 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission to a gateway connected to a PC or datalogger, range 5km (with gateway). |
| SFL.SMS-PSFLSMSP | Description: GSM/GPRS radio acquisition and transmission interface for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data is transmitted every 30 minutes directly to the cloud, accessible via web browser or app. |
| SFL.SigFox-PSFLSigFoxP | Description: Wireless acquisition and transmission interface for the SigFox IoT platform, 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission every 15 minutes directly to the cloud, accessible via browser or app. |
| Reference | Configuration |
|---|
| ASTIDR-90ASTIDR90 | Description: Vertical aluminum hydrometric sight, painted in bright yellow with anti-corrosion treatment and black screen printing, complete with 3-digit level plate and brackets |
| Reference | Configuration |
|---|
| GPRSGPRS | Description: Quad-band GPRS/UMTS industrial modem with omnidirectional antenna and cable for serial data communication. SIM card not included. |
| Reference | Configuration |
|---|
| MCSMCS | Description: DIN rail module, pre-programmed for the conversion of input signals: Pt100, thermopile, voltages (micro-voltages 0-100mV) and currents or digital signals (frequency or count), and output signals: 0-2Vdc, 0-20mA, 4-20mA, RS485, Modbus RTU RS485. The selected input and output types are indicated. |
| Reference | Configuration |
|---|
| e-BareBar | Supply: Electronic barometer inside the Evolution datalogger; programmable range, standard 500-1100 hPa; read directly by the datalogger as it is mounted on the motherboard |
| Reference | Configuration |
|---|
| RSG1-ARSG1A | Model: RSG1 · Output signal: 0÷2Vdc · Supplied with: Calibration report |
| RSG1-BRSG1B | Model: RSG1 · Output signal: 4÷20mA · Supplied with: Calibration report |
| RSG1-CRSG1C | Model: RSG1 · Output signal: RS485 / Modbus (Standard ID 003) · Supplied with: Calibration report |
| RSG1-NRSG1N | Model: RSG1 · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report |
| Reference | Configuration |
|---|
| RSG-ARSGA | Model: RSG · Output signal: 0÷2Vdc · Supplied with: Calibration report |
| RSG-BRSGB | Model: RSG · Output signal: 4÷20mA · Supplied with: Calibration report |
| RSG-CRSGC | Model: RSG · Output signal: RS485 / Modbus (Standard ID 003) · Supplied with: Calibration report |
| RSG-NRSGN | Model: RSG · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report |
| Reference | Configuration |
|---|
| RSG2Std-ARSG2StdA | Model: RSG2Std · Output signal: 0÷1Vdc · Supply: With 5m cable calibration report |
| RSG2Std-BRSG2StdB | Model: RSG2Std · Output signal: 4÷20mA · Supply: With 5m cable calibration report |
| RSG2Std-NRSG2StdN | Model: RSG2Std · Output signal: Natural in µV · Supply: With 5m cable calibration report |
| RSG2Std-cRSG2Stdc | Model: RSG2Std · Output signal: RS485 / Modbus (Standard ID 003) · Supply: With 5m cable calibration report |
| Reference | Configuration |
|---|
| PYREPYRE | Model: PIR · Output signal: 0÷1Vdc (configurable to 0÷2Vdc) · Supplied with: Calibration report |
| PIR-BPIRB | Model: PIR · Output signal: 4÷20mA · Supplied with: Calibration report |
| PIR-NPIRN | Model: PIR · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report |
| Reference | Configuration |
|---|
| M2CH.BM2CHB | Label: Blue · Version for: 0÷5Vdc, 0÷10Vdc or other voltage range, or specific sensors from other manufacturers |
| M2CH.RM2CHR | Label: Red · Version for: 0÷20mA or 4÷20mA, or specific sensors from other manufacturers |
| M2CH.WM2CHW | Label: White · Version for: 0÷2Vdc, Pt100 or mV sensors, frequencies, pulses, or specific sensors from other manufacturers |
| M2CH.YM2CHY | Label: Yellow · Version for: Sinusoidal outputs, or specific sensors from other manufacturers |
| Reference | Configuration |
|---|
| PL1000-APL1000A | Heater: No · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000-BPL1000B | Heater: No · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000-CPL1000C | Heater: No · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000-NPL1000N | Heater: No · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-APL1000RA | Heater: Max. 60 W, with integrated temperature control system · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-BPL1000RB | Heater: Max. 60 W, with integrated temperature control system · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-CPL1000RC | Heater: Max. 60 W, with integrated temperature control system · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000R-NPL1000RN | Heater: Max. 60 W, with integrated temperature control system · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| Reference | Configuration |
|---|
| PL400-APL400A | Heater: No · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL400-BPL400B | Heater: No · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 11452:2012 · Supplied: With flange for poles of max. Ø 59/80 mm and calibration report |
| PL400-CPL400C | Heater: No · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL400-NPL400N | Heater: No · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL400R-APL400RA | Heater: Max. 60 W, with integrated temperature control system · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL400R-BPL400RB | Heater: Max. 60 W, with integrated temperature control system · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL400R-CPL400RC | Heater: Max. 60 W, with integrated temperature control system · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL400R-NPL400RN | Heater: Max. 60 W, with integrated temperature control system · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| Reference | Configuration |
|---|
| RSN-ARSNA | Model: RSN · Output signal: 0÷2Vdc · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report |
| RSN-BRSNB | Model: RSN · Output signal: 4÷20mA · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report |
| RSN-CRSNC | Model: RSN · Output signal: RS485 / Modbus (Standard ID 011) · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report |
| RSN-NRSNN | Model: RSN · Output signal: Natural, ±20 mV · Range: ± 2000 W/m² · Supplied with: Calibration report |
| Reference | Configuration |
|---|
| S-NH3SNH3 | Output: Modbus RTU · Supply: Full scale 100 ppm or 1000 ppm, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| S-VOCSVOC | Output: ModBus RTU · Supply: Range 0…100 to 0…1000 ppm, with 1 m cable |
| Reference | Configuration |
|---|
| S-SO2SSO2 | Output: Modbus RTU · Supply: Full scale 50 ppm, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| S-CO2SCO2 | Output: Modbus RTU · Supply: Full scale 10000 ppm, IP54/IP65, with 1 m cable |
| Reference | Configuration |
|---|
| S-NO2SNO2 | Output: Modbus RTU · Supply: Full scale 20 ppm or 200 ppm, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| SSASSA | Output: RS485 · Description: Passive road surface condition sensor with isolated RS485 interface |
| Reference | Configuration |
|---|
| FAT-BFATB | Model: FAT · Output signal: Dual 4÷20mA output · Supplied with: 5m cable, protective ball for the sensitive element and ring; calibration report; stand not included |
| Reference | Configuration |
|---|
| SFT-NSFTN | Output: Natural, thermopile (mV) · Supply: With calibration report and 5 m cable |
| Reference | Configuration |
|---|
| BF-ABFA | Output: 0-2Vdc · Supply: With calibration report; cable and stand separate (CS05, CS10, CSxx, SSU) |
| BF-BBFB | Output: 4÷20mA · Supply: With calibration report; cable and bracket separate (CS05, CS10, CSxx, SSU) |
| BF-CBFC | Output: RS485 / Modbus · Supply: With calibration report; cable and bracket separate (CS05, CS10, CSxx, SSU) |
| Reference | Configuration |
|---|
| UR-AURA | Model: UR · Ventilation: Natural · Output signal: 0÷1Vdc (0 ÷ 100 %Rh) |
| UR-BURB | Model: UR · Ventilation: Natural · Output signal: 4÷20mA (0 ÷ 100 %Rh) |
| UR-CURC | Model: UR · Ventilation: Natural · Output signal: RS485 / ModBus RTU |
| URV-AURVA | Model: URV · Ventilation: Forced · Output signal: 0÷1Vdc (0 ÷ 100 %Rh) |
| URV-BURVB | Model: URV · Ventilation: Forced · Output signal: 4÷20mA (0 ÷ 100 %Rh) |
| URV-CURVC | Model: URV · Ventilation: Forced · Output signal: RS485 / ModBus RTU |
| Reference | Configuration |
|---|
| URI-AURIA | Model: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: 0÷1Vdc, with 5 m cable |
| URI-BURIB | Model: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: 4÷20mA, with 5 m cable |
| URI-CURIC | Model: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: RS485/Modbus, with 5 m cable |
| Reference | Configuration |
|---|
| SM.2-ASM2A | Output: 0–2Vdc; Supply: 0–100% VWC, -40–+70°C; with 3m cable calibration report |
| SM.2-BSM2B | Output: 4÷20mA · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report |
| SM.2-CSM2C | Output: RS485/Modbus · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report |
| Reference | Configuration |
|---|
| SM.3-ASM3A | Output: 0–2Vdc; Supply: 0–100% VWC, -40–+70°C; with 3m cable calibration report |
| SM.3-BSM3B | Output: 4÷20mA · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report |
| SM.3-CSM3C | Output: RS485/Modbus · Supply: 0÷100% VWC, -40 ÷ +70°C, 0÷20ms; with 3m cable calibration report |
| Reference | Configuration |
|---|
| LUX-ALUXA | Model: LUX · Output signal: 0÷10Vdc · Supply: Range a, mouth indicate; with 5m cable calibration report |
| LUX-BLUXB | Model: LUX · Output signal: 4÷20mA · Supply: Range a, mouth indicate; with 5m cable calibration report |
| Reference | Configuration |
|---|
| S-CH4SCH4 | Output: Modbus RTU · Supply: Full scale 100% v/v, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| S-COSCO | Output: ModBus RTU · Supply: Full scale 300 ppm or 1000 ppm, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| S-NOSNO | Output: 4÷20mA / ModBus RTU · Supply: Range 250 ppm, with 1 m cable |
| Reference | Configuration |
|---|
| LP05-BLP05B | Range: 0–5 m H2O · Output: 4–20 mA · Supply: With 5 m compensated cable; calibration report |
| LP10-BLP10B | Range: 0–10 m H2O · Output: 4–20 mA · Supply: With 10 m compensated cable; calibration report |
| LP15-BLP15B | Range: 0–15 m H2O · Output: 4–20 mA · Supply: With 15 m compensated cable; calibration report |
| LP20-BLP20B | Range: 0÷20 m H2O · Output: 4÷20mA · Supply: With 20 m compensated cable, calibration report |
| LP30-BLP30B | Range: 0-30 m H2O · Output: 4-20 mA · Supply: With 30 m compensated cable, calibration report |
| LP50-BLP50B | Range: 0–50 m H2O · Output: 4–20 mA · Supply: With 50 m compensated cable; calibration report |
| Reference | Configuration |
|---|
| LU06-BLU06B | Range: 0–6 m · Output: 4–20 mA · Supply: With calibration report |
| Reference | Configuration |
|---|
| LR15-BLR15B | Range: 0-15 m · Output: 4-20 mA · Supplied with: Calibration report and 5 m cable |
| LR20-BLR20B | Range: 0-20 m · Output: 4-20 mA · Supplied with: Calibration report and 5 m cable |
| LR35-BLR35B | Range: 0÷35 m · Output: 4÷20mA · Supply: With calibration report |
| Reference | Configuration |
|---|
| S-O2SO2 | Output: Modbus RTU · Supply: Full scale 25% v/v, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| S-O3SO3 | Output: 4÷20mA / ModBus · Supply: Range 0÷5 ppm, with 1 m cable |
| Reference | Configuration |
|---|
| FM-PM-BFMPMB | Output: 2 x 4-20mA · Description: PM2.5-PM10 dust sensor, range 0÷1000 µg/m³, laser diffusion principle |
| FM-PM-CFMPMC | Output: ModBus RS485 · Description: PM2.5-PM10 dust sensor, range 0÷1000 µg/m³, laser diffusion principle |
| Reference | Configuration |
|---|
| SPPSPP | Output: ON/OFF with dry contact · Supply: With 2 m cable included |
| Reference | Configuration |
|---|
| BAR-ABARA | Output signal: 0÷2Vdc · Supply: 800÷1100 hPa, compliant with WMO, with calibration report; also available with separate cable (CS05, CS10, CSxx) |
| BAR-BBARB | Output signal: 4÷20mA · Supply: 800÷1100 hPa, compliant with WMO, with calibration report; also with separate cable (CS05, CS10, CSxx) |
| BAR-CBARC | Output signal: RS485 / Modbus · Supply: 800÷1100 hPa, compliant with WMO, RS485 / Modbus or RS485 with serial protocol, standard ID 013, with calibration report; also with separate cable (CS05, CS10, CSxx) |
| Reference | Configuration |
|---|
| S-H2SSH2S | Output: ModBus RTU · Supply: Full scale 100 ppm or 2000 ppm, IP54, with 1 m cable |
| Reference | Configuration |
|---|
| TC-NTCN | Model: TC · Construction: Aluminum with adhesive flat base (30 x 10 x 5 mm), IP66 · Output signal and cable: Natural Pt100 1/3DIN 4-wire, with 10 m cable, calibration report |
| Reference | Configuration |
|---|
| GTA-NGTAN | Model: GTA · Sensitive element: Pt100 1/3 DIN (100 Ω @ 0 °C) in matte black copper sphere · Output signal: Natural Pt100 4-wire, with 2m cable calibration report |
| Reference | Configuration |
|---|
| TAI-BTAIB | Model: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: 4÷20mA, with 5 m cable |
| TAI-CTAIC | Model: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: RS485/Modbus, with 5 m cable |
| TAI-NTAIN | Model: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: Pt100 1/3DIN 4-wire, with 5 m cable |
| Reference | Configuration |
|---|
| TA-ATAA | Model: TA · Ventilation: Natural · Output signal: 0÷2Vdc (-40 ÷ +60 °C) |
| TA-BTAB | Model: TA · Ventilation: Natural · Output signal: 4÷20mA (-40 ÷ +60 °C) |
| TA-CCT scan | Model: TA · Ventilation: Natural · Output signal: RS485 / ModBus RTU |
| SOSO | Model: TA · Ventilation: Natural · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire |
| TAV-ATAVA | Model: TAV · Ventilation: Forced · Output signal: 0÷2Vdc (-40 ÷ +60 °C) |
| TAV-BTAVB | Model: TAV · Ventilation: Forced · Output signal: 4÷20mA (-40 ÷ +60 °C) |
| TAV-CTAVC | Model: TAV · Ventilation: Forced · Output signal: RS485 / ModBus RTU |
| TAV-NTAVN | Model: TAV · Ventilation: Forced · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire |
| Reference | Configuration |
|---|
| SSTSST | Output: Pt100 4-wire · Supply: With calibration report and 10 m cable |
| Reference | Configuration |
|---|
| VIS-BVISB | Output: 4÷20mA · Range: 10 ÷ 40,000 m · Power supply: 10÷35Vdc · Supply: Heated version R; 5 m cable included |
| VIS-CVISC | Output: RS485 · Range: 10 ÷ 40,000 m · Power supply: 10÷35Vdc · Supply: Heated version R; 5 m cable included |
| VIS-LVISL | Output: RS485 and 0-10Vdc · Range: 10-7500 m · Power supply: 10-35Vdc · Supplied with: 5 m cable included |
| Reference | Configuration |
|---|
| TQ-NTQN | Output: Natural, Pt100 4-wire · Model: Water temperature sensor |
| TT-NTTN | Output: Natural, Pt100 4-wire · Model: Ground temperature sensor |
| Reference | Configuration |
|---|
| TORB-WMP6xTORBWMP6x | Description: Turbidity sensor for WMP6x multiparameter probe, measuring range 0÷4000 NTU |
| WMP6WMP6 | Description: Multiparameter probe with 6 measurements (level, temperature, conductivity, pH, redox, and dissolved oxygen), maximum measurable depth 20 m, 30 m self-supporting shielded cable with internal barometric compensation tube, 12Vdc external power supply, RS485 output protocol, no data logger, with calibration report. Portable configuration includes S/USB interface and IP68 AMP connector |
| WMP6pWMP6p | Description: Multiparameter probe for deep water, measuring 6 parameters (level, temperature, conductivity, pH, redox, and dissolved oxygen), maximum measurable depth 350 m, external 12Vdc power supply, RS485 output protocol, with calibration report; no data logger, no barometer for pressure compensation, and no cable. The portable configuration includes an S/USB interface and IP68 AMP connector. |
| Reference | Configuration |
|---|
| UTAI-BUTAIB | Model: UTAI · Temperature (T) Output: 4÷20mA · Humidity (RH) Output: 4÷20mA |
| UTAI-CUTAI | Model: UTAI · Temperature (T) Output: RS485 / ModBus · Humidity (RH) Output: RS485 / ModBus |
| UTAI-NUTAIN | Model: UTAI · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc |
| Reference | Configuration |
|---|
| UTA-AUTAA | Model: UTA · Ventilation: Natural · Temperature Output (T): 0÷1Vdc (configurable to 0÷2Vdc) · Humidity Output (RH): 0÷1Vdc |
| UTA-BUTAB | Model: UTA · Ventilation: Natural · Temperature Outlet (T): 4÷20mA · Humidity Outlet (RH): 4÷20mA |
| UTA-CUTAC | Model: UTA · Ventilation: Natural · Temperature (T) Output: RS485 / Modbus · Humidity (RH) Output: RS485 / Modbus |
| UTA-NUTAN | Model: UTA · Ventilation: Natural · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc |
| UTAV-AUTAVA | Model: UTAV · Ventilation: Forced · Temperature Output (T): 0÷1Vdc (configurable to 0÷2Vdc) · Humidity Output (RH): 0÷1Vdc |
| UTAV-BUTAVB | Model: UTAV · Ventilation: Forced · Temperature Output (T): 4÷20mA · Humidity Output (RH): 4÷20mA |
| UTAV-CUTAVC | Model: UTAV · Ventilation: Forced · Temperature (T) Output: RS485 / Modbus · Humidity (RH) Output: RS485 / Modbus |
| UTAV-NUTAVN | Model: UTAV · Ventilation: Forced · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc |
| Reference | Configuration |
|---|
| DVE-ADVEA | Model: DVE · Heating: Standard · Output signal: 0÷2Vdc (0÷360°) |
| DVE-BDVEB | Model: DVE · Heating: Standard · Output signal: 4÷20mA (0÷360°) |
| DVE-CDVEC | Model: DVE · Heating: Standard · Output signal: RS485/Modbus, standard ID: 004 |
| DVER-ADVERA | Model: DVER · Heating: Heated (Pw<5W) · Output signal: 0÷2Vdc (0÷360°) |
| DVER-BDVERB | Model: DVER · Heating: Heated (Pw<5W) · Output signal: 4÷20mA (0÷360°) |
| DVER-CDVERC | Model: DVER · Heating: Heated (Pw<5W) · Output signal: RS485/Modbus, standard ID: 004 |