NESA order references

NESA order references

Order references for NESA sensors and equipment (166 references for 61 products). Each reference links to its corresponding product data sheet line, with its configuration. Guemisa is an official NESA distributor in Spain. If you cannot find your product, please email us at ventas@guemisa.com with the label code and we will identify it.

ALB Albedometer (1)

ReferenceConfiguration
ALB-NALBNModel: ALB · Output signal: Dual natural µV output · Supply: With calibration report

First Class VV1 / VV1R cup anemometer (8)

ReferenceConfiguration
VV1-AVV1AModel: VV1 · Heating: Standard · Output signal: 0÷2Vdc
VV1-BVV1BModel: VV1 · Heating: Standard · Output signal: 4÷20mA
VV1-CVV1CModel: VV1 · Heating: Standard · Output signal: RS485/Modbus (Standard ID 009)
VV1-NVV1NModel: VV1 · Heating: Standard · Output Signal: Frequency 0÷150Hz or 0÷300Hz
VV1R-AVV1RAModel: VV1R · Heating: Heated (Pw<5W) · Output signal: 0÷2Vdc
VV1R-BVV1RBModel: VV1R · Heating: Heated (Pw<5W) · Output signal: 4÷20mA
VV1R-CVV1RCModel: VV1R · Heating: Heated (Pw<5W) · Output signal: RS485/Modbus (Standard ID 009)
VV1R-NVV1RNModel: VV1R · Heating: Heated (Pw<5W) · Output signal: Frequency 0÷150Hz or 0÷300Hz

ANEST triaxial sonic anemometer (1)

ReferenceConfiguration
ANESTANESTTechnical description: Static triaxial sonic anemometer for wind speed and direction, UVW Cartesian components and sonic temperature. Output: RS485 or analog channels; with calibration report

ANESB biaxial ultrasonic anemometer (4)

ReferenceConfiguration
ANESB-BANESBBModel: ANESB · Heating: Not heated · Output signal: Dual 4÷20mA output (speed and direction)
ANESB-CANESBCModel: ANESB · Heating: Not heated · Output signal: RS485/Modbus
ANESBR-BANESBRBModel: ANESBR · Heating: Heated (10W) · Output signal: Dual 4÷20mA output (speed and direction)
ANESBR-CANESBRCModel: ANESBR · Heating: Heated (10W) · Output signal: RS485/Modbus

ANESR biaxial ultrasonic anemometer (1)

ReferenceConfiguration
ANESRANESRModel: ANESR · Speed and direction range: 0 ÷ 50 m/s · 0 ÷ 360° · Output signal: 2 x 4÷20mA, with calibration report

BAR-AV Precision Digital Barometer (2)

ReferenceConfiguration
BAR-AVBARAVTransducers: 1 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable
BAR-AV-SBARAVSTransducers: 3 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable

SSU sensor support arm (1)

ReferenceConfiguration
SSUSSUDescription: Support arm, length 700/750 mm, with Ø 40 mm clamping jaws for sensors and fixing to posts of max. Ø 60 mm. Stainless steel screws

CSxx sensor-datalogger shielded cable (9)

ReferenceConfiguration
CS05CS05Description: Shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 5 m
CS05-SCS05SDescription: Custom shielded sensor-datalogger cable, with ferrules on the datalogger side and a connector on the sensor side. Length: 5 m
CS05RCS05RDescription: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 5 m
CS10CS10Description: Shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 10 m
CS10-SCS10SDescription: Custom shielded sensor-datalogger cable, with ferrules on the datalogger side and a connector on the sensor side. Length: 10 m
CS10RCS10RDescription: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length: 10 m
CSxxCSxxDescription: Shielded sensor-datalogger cable, with PS/2 connector or ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length xx m
CSxx-SCSxxSDescription: Custom shielded sensor-datalogger cable, with PS/2 connector or ferrules on the datalogger side and a connector on the sensor side. Length xx m
CSxxRCSxxRDescription: Heated shielded sensor-datalogger cable, with ferrules on the datalogger side and a 7-pin IP68 connector on the sensor side. Length xx m

Modular datalogger with Linux Evolution-M (1)

ReferenceConfiguration
Evolution-MEvolutionMDescription: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD.

Modular datalogger with Linux Evolution system (1)

ReferenceConfiguration
EvolutionEvolutionDescription: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD, DIN rail mount.

DIS radar disdrometer (1)

ReferenceConfiguration
DISDISOutput: RS485 · Supply: With 10m cable included

SFL IoT Radio Interface (4)

ReferenceConfiguration
SFL.Lora-PSFLLoraPDescription: Wireless acquisition and transmission interface for IoT LoRa/LoRaWAN platform, 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission every 15 minutes directly to the cloud, accessible via browser or app.
SFL.NESA-PSFLNESAPDescription: Wireless acquisition and transmission interface with NESA protocol – 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission to a gateway connected to a PC or datalogger, range 5km (with gateway).
SFL.SMS-PSFLSMSPDescription: GSM/GPRS radio acquisition and transmission interface for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data is transmitted every 30 minutes directly to the cloud, accessible via web browser or app.
SFL.SigFox-PSFLSigFoxPDescription: Wireless acquisition and transmission interface for the SigFox IoT platform, 868MHz (Europe), for low-power analog or digital sensors; rechargeable battery and 5W solar panel included. Data transmission every 15 minutes directly to the cloud, accessible via browser or app.

ASTA-IDR graduated aluminum hydrometric sight (1)

ReferenceConfiguration
ASTIDR-90ASTIDR90Description: Vertical aluminum hydrometric sight, painted in bright yellow with anti-corrosion treatment and black screen printing, complete with 3-digit level plate and brackets

GSM-GPRS-UMTS GPRS industrial modem (1)

ReferenceConfiguration
GPRSGPRSDescription: Quad-band GPRS/UMTS industrial modem with omnidirectional antenna and cable for serial data communication. SIM card not included.

MCS Signal Conditioning Module (1)

ReferenceConfiguration
MCSMCSDescription: DIN rail module, pre-programmed for the conversion of input signals: Pt100, thermopile, voltages (micro-voltages 0-100mV) and currents or digital signals (frequency or count), and output signals: 0-2Vdc, 0-20mA, 4-20mA, RS485, Modbus RTU RS485. The selected input and output types are indicated.

e-Bar internal barometer option for Evolution datalogger (1)

ReferenceConfiguration
e-BareBarSupply: Electronic barometer inside the Evolution datalogger; programmable range, standard 500-1100 hPa; read directly by the datalogger as it is mounted on the motherboard

First-class pyranometer RSG1 (4)

ReferenceConfiguration
RSG1-ARSG1AModel: RSG1 · Output signal: 0÷2Vdc · Supplied with: Calibration report
RSG1-BRSG1BModel: RSG1 · Output signal: 4÷20mA · Supplied with: Calibration report
RSG1-CRSG1CModel: RSG1 · Output signal: RS485 / Modbus (Standard ID 003) · Supplied with: Calibration report
RSG1-NRSG1NModel: RSG1 · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report

RSG Second Class Pyranometer (4)

ReferenceConfiguration
RSG-ARSGAModel: RSG · Output signal: 0÷2Vdc · Supplied with: Calibration report
RSG-BRSGBModel: RSG · Output signal: 4÷20mA · Supplied with: Calibration report
RSG-CRSGCModel: RSG · Output signal: RS485 / Modbus (Standard ID 003) · Supplied with: Calibration report
RSG-NRSGNModel: RSG · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report

Secondary Standard Pyranometer RSG2std (4)

ReferenceConfiguration
RSG2Std-ARSG2StdAModel: RSG2Std · Output signal: 0÷1Vdc · Supply: With 5m cable calibration report
RSG2Std-BRSG2StdBModel: RSG2Std · Output signal: 4÷20mA · Supply: With 5m cable calibration report
RSG2Std-NRSG2StdNModel: RSG2Std · Output signal: Natural in µV · Supply: With 5m cable calibration report
RSG2Std-cRSG2StdcModel: RSG2Std · Output signal: RS485 / Modbus (Standard ID 003) · Supply: With 5m cable calibration report

PIR Pyrheliometer (3)

ReferenceConfiguration
PYREPYREModel: PIR · Output signal: 0÷1Vdc (configurable to 0÷2Vdc) · Supplied with: Calibration report
PIR-BPIRBModel: PIR · Output signal: 4÷20mA · Supplied with: Calibration report
PIR-NPIRNModel: PIR · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report

M2CH Sensor Interface Board (4)

ReferenceConfiguration
M2CH.BM2CHBLabel: Blue · Version for: 0÷5Vdc, 0÷10Vdc or other voltage range, or specific sensors from other manufacturers
M2CH.RM2CHRLabel: Red · Version for: 0÷20mA or 4÷20mA, or specific sensors from other manufacturers
M2CH.WM2CHWLabel: White · Version for: 0÷2Vdc, Pt100 or mV sensors, frequencies, pulses, or specific sensors from other manufacturers
M2CH.YM2CHYLabel: Yellow · Version for: Sinusoidal outputs, or specific sensors from other manufacturers

Class A rocker rain gauge PL1000 and PL1000R (8)

ReferenceConfiguration
PL1000-APL1000AHeater: No · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report
PL1000-BPL1000BHeater: No · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for poles of max. Ø 59/80 mm and calibration report
PL1000-CPL1000CHeater: No · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report
PL1000-NPL1000NHeater: No · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report
PL1000R-APL1000RAHeater: Max. 60 W, with integrated temperature control system · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report
PL1000R-BPL1000RBHeater: Max. 60 W, with integrated temperature control system · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report
PL1000R-CPL1000RCHeater: Max. 60 W, with integrated temperature control system · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report
PL1000R-NPL1000RNHeater: Max. 60 W, with integrated temperature control system · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report

Class A rocker rain gauge PL400 and PL400R (8)

ReferenceConfiguration
PL400-APL400AHeater: No · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report
PL400-BPL400BHeater: No · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 11452:2012 · Supplied: With flange for poles of max. Ø 59/80 mm and calibration report
PL400-CPL400CHeater: No · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report
PL400-NPL400NHeater: No · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report
PL400R-APL400RAHeater: Max. 60 W, with integrated temperature control system · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report
PL400R-BPL400RBHeater: Max. 60 W, with integrated temperature control system · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report
PL400R-CPL400RCHeater: Max. 60 W, with integrated temperature control system · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report
PL400R-NPL400RNHeater: Max. 60 W, with integrated temperature control system · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report

Net Radiometer RSN (4)

ReferenceConfiguration
RSN-ARSNAModel: RSN · Output signal: 0÷2Vdc · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report
RSN-BRSNBModel: RSN · Output signal: 4÷20mA · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report
RSN-CRSNCModel: RSN · Output signal: RS485 / Modbus (Standard ID 011) · Range: −500 ÷ 1500 W/m² · Supplied with: Calibration report
RSN-NRSNNModel: RSN · Output signal: Natural, ±20 mV · Range: ± 2000 W/m² · Supplied with: Calibration report

Ammonia sensor S-NH3 (1)

ReferenceConfiguration
S-NH3SNH3Output: Modbus RTU · Supply: Full scale 100 ppm or 1000 ppm, IP54, with 1 m cable

S-VOC volatile organic compound sensor (1)

ReferenceConfiguration
S-VOCSVOCOutput: ModBus RTU · Supply: Range 0…100 to 0…1000 ppm, with 1 m cable

Sulfur dioxide sensor S-SO2 (1)

ReferenceConfiguration
S-SO2SSO2Output: Modbus RTU · Supply: Full scale 50 ppm, IP54, with 1 m cable

Carbon dioxide sensor S-CO2 (1)

ReferenceConfiguration
S-CO2SCO2Output: Modbus RTU · Supply: Full scale 10000 ppm, IP54/IP65, with 1 m cable

Nitrogen dioxide sensor S-NO2 (1)

ReferenceConfiguration
S-NO2SNO2Output: Modbus RTU · Supply: Full scale 20 ppm or 200 ppm, IP54, with 1 m cable

SSA Road Condition Sensor (1)

ReferenceConfiguration
SSASSAOutput: RS485 · Description: Passive road surface condition sensor with isolated RS485 interface

FAT Airflow and Temperature Sensor (1)

ReferenceConfiguration
FAT-BFATBModel: FAT · Output signal: Dual 4÷20mA output · Supplied with: 5m cable, protective ball for the sensitive element and ring; calibration report; stand not included

Soil Thermal Flow Sensor SFT (1)

ReferenceConfiguration
SFT-NSFTNOutput: Natural, thermopile (mV) · Supply: With calibration report and 5 m cable

BF Foliar Wetting Sensor (3)

ReferenceConfiguration
BF-ABFAOutput: 0-2Vdc · Supply: With calibration report; cable and stand separate (CS05, CS10, CSxx, SSU)
BF-BBFBOutput: 4÷20mA · Supply: With calibration report; cable and bracket separate (CS05, CS10, CSxx, SSU)
BF-CBFCOutput: RS485 / Modbus · Supply: With calibration report; cable and bracket separate (CS05, CS10, CSxx, SSU)

UR air relative humidity sensor (6)

ReferenceConfiguration
UR-AURAModel: UR · Ventilation: Natural · Output signal: 0÷1Vdc (0 ÷ 100 %Rh)
UR-BURBModel: UR · Ventilation: Natural · Output signal: 4÷20mA (0 ÷ 100 %Rh)
UR-CURCModel: UR · Ventilation: Natural · Output signal: RS485 / ModBus RTU
URV-AURVAModel: URV · Ventilation: Forced · Output signal: 0÷1Vdc (0 ÷ 100 %Rh)
URV-BURVBModel: URV · Ventilation: Forced · Output signal: 4÷20mA (0 ÷ 100 %Rh)
URV-CURVCModel: URV · Ventilation: Forced · Output signal: RS485 / ModBus RTU

URI Indoor Relative Humidity Sensor (3)

ReferenceConfiguration
URI-AURIAModel: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: 0÷1Vdc, with 5 m cable
URI-BURIBModel: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: 4÷20mA, with 5 m cable
URI-CURICModel: URI · Body: Plastic, 26 x 220 mm · Output signal and supply: RS485/Modbus, with 5 m cable

SM.2 Soil moisture and temperature sensor (3)

ReferenceConfiguration
SM.2-ASM2AOutput: 0–2Vdc; Supply: 0–100% VWC, -40–+70°C; with 3m cable calibration report
SM.2-BSM2BOutput: 4÷20mA · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report
SM.2-CSM2COutput: RS485/Modbus · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report

SM.3 Soil moisture, temperature and conductivity sensor (3)

ReferenceConfiguration
SM.3-ASM3AOutput: 0–2Vdc; Supply: 0–100% VWC, -40–+70°C; with 3m cable calibration report
SM.3-BSM3BOutput: 4÷20mA · Supply: 0÷100% VWC, -40 ÷ +70°C; with 3m cable calibration report
SM.3-CSM3COutput: RS485/Modbus · Supply: 0÷100% VWC, -40 ÷ +70°C, 0÷20ms; with 3m cable calibration report

LUX illuminance sensor (2)

ReferenceConfiguration
LUX-ALUXAModel: LUX · Output signal: 0÷10Vdc · Supply: Range a, mouth indicate; with 5m cable calibration report
LUX-BLUXBModel: LUX · Output signal: 4÷20mA · Supply: Range a, mouth indicate; with 5m cable calibration report

S-CH4 methane sensor (1)

ReferenceConfiguration
S-CH4SCH4Output: Modbus RTU · Supply: Full scale 100% v/v, IP54, with 1 m cable

S-CO Carbon Monoxide Sensor (1)

ReferenceConfiguration
S-COSCOOutput: ModBus RTU · Supply: Full scale 300 ppm or 1000 ppm, IP54, with 1 m cable

Nitrogen monoxide sensor S-NO (1)

ReferenceConfiguration
S-NOSNOOutput: 4÷20mA / ModBus RTU · Supply: Range 250 ppm, with 1 m cable

LPxx Piezometric Level Sensor (6)

ReferenceConfiguration
LP05-BLP05BRange: 0–5 m H2O · Output: 4–20 mA · Supply: With 5 m compensated cable; calibration report
LP10-BLP10BRange: 0–10 m H2O · Output: 4–20 mA · Supply: With 10 m compensated cable; calibration report
LP15-BLP15BRange: 0–15 m H2O · Output: 4–20 mA · Supply: With 15 m compensated cable; calibration report
LP20-BLP20BRange: 0÷20 m H2O · Output: 4÷20mA · Supply: With 20 m compensated cable, calibration report
LP30-BLP30BRange: 0-30 m H2O · Output: 4-20 mA · Supply: With 30 m compensated cable, calibration report
LP50-BLP50BRange: 0–50 m H2O · Output: 4–20 mA · Supply: With 50 m compensated cable; calibration report

LU06 Ultrasonic Level Sensor (1)

ReferenceConfiguration
LU06-BLU06BRange: 0–6 m · Output: 4–20 mA · Supply: With calibration report

LR20 Radar Level Sensor (3)

ReferenceConfiguration
LR15-BLR15BRange: 0-15 m · Output: 4-20 mA · Supplied with: Calibration report and 5 m cable
LR20-BLR20BRange: 0-20 m · Output: 4-20 mA · Supplied with: Calibration report and 5 m cable
LR35-BLR35BRange: 0÷35 m · Output: 4÷20mA · Supply: With calibration report

Oxygen sensor S-O2 (1)

ReferenceConfiguration
S-O2SO2Output: Modbus RTU · Supply: Full scale 25% v/v, IP54, with 1 m cable

S-O3 ozone sensor (1)

ReferenceConfiguration
S-O3SO3Output: 4÷20mA / ModBus · Supply: Range 0÷5 ppm, with 1 m cable

FM-PM PM2.5 – PM10 Dust Sensor (2)

ReferenceConfiguration
FM-PM-BFMPMBOutput: 2 x 4-20mA · Description: PM2.5-PM10 dust sensor, range 0÷1000 µg/m³, laser diffusion principle
FM-PM-CFMPMCOutput: ModBus RS485 · Description: PM2.5-PM10 dust sensor, range 0÷1000 µg/m³, laser diffusion principle

Rain and snow presence sensor SPP (1)

ReferenceConfiguration
SPPSPPOutput: ON/OFF with dry contact · Supply: With 2 m cable included

Atmospheric pressure sensor BAR (3)

ReferenceConfiguration
BAR-ABARAOutput signal: 0÷2Vdc · Supply: 800÷1100 hPa, compliant with WMO, with calibration report; also available with separate cable (CS05, CS10, CSxx)
BAR-BBARBOutput signal: 4÷20mA · Supply: 800÷1100 hPa, compliant with WMO, with calibration report; also with separate cable (CS05, CS10, CSxx)
BAR-CBARCOutput signal: RS485 / Modbus · Supply: 800÷1100 hPa, compliant with WMO, RS485 / Modbus or RS485 with serial protocol, standard ID 013, with calibration report; also with separate cable (CS05, CS10, CSxx)

Hydrogen sulfide sensor S-H2S (1)

ReferenceConfiguration
S-H2SSH2SOutput: ModBus RTU · Supply: Full scale 100 ppm or 2000 ppm, IP54, with 1 m cable

TC Contact Temperature Sensor (1)

ReferenceConfiguration
TC-NTCNModel: TC · Construction: Aluminum with adhesive flat base (30 x 10 x 5 mm), IP66 · Output signal and cable: Natural Pt100 1/3DIN 4-wire, with 10 m cable, calibration report

GTA black globe temperature sensor (1)

ReferenceConfiguration
GTA-NGTANModel: GTA · Sensitive element: Pt100 1/3 DIN (100 Ω @ 0 °C) in matte black copper sphere · Output signal: Natural Pt100 4-wire, with 2m cable calibration report

TAI Indoor Air Temperature Sensor (3)

ReferenceConfiguration
TAI-BTAIBModel: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: 4÷20mA, with 5 m cable
TAI-CTAICModel: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: RS485/Modbus, with 5 m cable
TAI-NTAINModel: TAI · Body: Plastic, 26 x 220 mm · Output signal and supply: Pt100 1/3DIN 4-wire, with 5 m cable

TA air temperature sensor (8)

ReferenceConfiguration
TA-ATAAModel: TA · Ventilation: Natural · Output signal: 0÷2Vdc (-40 ÷ +60 °C)
TA-BTABModel: TA · Ventilation: Natural · Output signal: 4÷20mA (-40 ÷ +60 °C)
TA-CCT scanModel: TA · Ventilation: Natural · Output signal: RS485 / ModBus RTU
SOSOModel: TA · Ventilation: Natural · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire
TAV-ATAVAModel: TAV · Ventilation: Forced · Output signal: 0÷2Vdc (-40 ÷ +60 °C)
TAV-BTAVBModel: TAV · Ventilation: Forced · Output signal: 4÷20mA (-40 ÷ +60 °C)
TAV-CTAVCModel: TAV · Ventilation: Forced · Output signal: RS485 / ModBus RTU
TAV-NTAVNModel: TAV · Ventilation: Forced · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire

Soil surface temperature sensor (SST) (1)

ReferenceConfiguration
SSTSSTOutput: Pt100 4-wire · Supply: With calibration report and 10 m cable

Visibility sensor VIS (3)

ReferenceConfiguration
VIS-BVISBOutput: 4÷20mA · Range: 10 ÷ 40,000 m · Power supply: 10÷35Vdc · Supply: Heated version R; 5 m cable included
VIS-CVISCOutput: RS485 · Range: 10 ÷ 40,000 m · Power supply: 10÷35Vdc · Supply: Heated version R; 5 m cable included
VIS-LVISLOutput: RS485 and 0-10Vdc · Range: 10-7500 m · Power supply: 10-35Vdc · Supplied with: 5 m cable included

TT/TQ Soil and Water Temperature Sensors (2)

ReferenceConfiguration
TQ-NTQNOutput: Natural, Pt100 4-wire · Model: Water temperature sensor
TT-NTTNOutput: Natural, Pt100 4-wire · Model: Ground temperature sensor

WMP6 Multiparameter Water Quality Probe (3)

ReferenceConfiguration
TORB-WMP6xTORBWMP6xDescription: Turbidity sensor for WMP6x multiparameter probe, measuring range 0÷4000 NTU
WMP6WMP6Description: Multiparameter probe with 6 measurements (level, temperature, conductivity, pH, redox, and dissolved oxygen), maximum measurable depth 20 m, 30 m self-supporting shielded cable with internal barometric compensation tube, 12Vdc external power supply, RS485 output protocol, no data logger, with calibration report. Portable configuration includes S/USB interface and IP68 AMP connector
WMP6pWMP6pDescription: Multiparameter probe for deep water, measuring 6 parameters (level, temperature, conductivity, pH, redox, and dissolved oxygen), maximum measurable depth 350 m, external 12Vdc power supply, RS485 output protocol, with calibration report; no data logger, no barometer for pressure compensation, and no cable. The portable configuration includes an S/USB interface and IP68 AMP connector.

UTAI Indoor Temperature and Humidity Thermohygrometer (3)

ReferenceConfiguration
UTAI-BUTAIBModel: UTAI · Temperature (T) Output: 4÷20mA · Humidity (RH) Output: 4÷20mA
UTAI-CUTAIModel: UTAI · Temperature (T) Output: RS485 / ModBus · Humidity (RH) Output: RS485 / ModBus
UTAI-NUTAINModel: UTAI · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc

UTA air temperature and relative humidity thermohygrometer (8)

ReferenceConfiguration
UTA-AUTAAModel: UTA · Ventilation: Natural · Temperature Output (T): 0÷1Vdc (configurable to 0÷2Vdc) · Humidity Output (RH): 0÷1Vdc
UTA-BUTABModel: UTA · Ventilation: Natural · Temperature Outlet (T): 4÷20mA · Humidity Outlet (RH): 4÷20mA
UTA-CUTACModel: UTA · Ventilation: Natural · Temperature (T) Output: RS485 / Modbus · Humidity (RH) Output: RS485 / Modbus
UTA-NUTANModel: UTA · Ventilation: Natural · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc
UTAV-AUTAVAModel: UTAV · Ventilation: Forced · Temperature Output (T): 0÷1Vdc (configurable to 0÷2Vdc) · Humidity Output (RH): 0÷1Vdc
UTAV-BUTAVBModel: UTAV · Ventilation: Forced · Temperature Output (T): 4÷20mA · Humidity Output (RH): 4÷20mA
UTAV-CUTAVCModel: UTAV · Ventilation: Forced · Temperature (T) Output: RS485 / Modbus · Humidity (RH) Output: RS485 / Modbus
UTAV-NUTAVNModel: UTAV · Ventilation: Forced · Temperature (T) Output: Pt100 1/3DIN 4-wire · Humidity (RH) Output: 0÷1Vdc

Wind direction vane DVE / DVER (6)

ReferenceConfiguration
DVE-ADVEAModel: DVE · Heating: Standard · Output signal: 0÷2Vdc (0÷360°)
DVE-BDVEBModel: DVE · Heating: Standard · Output signal: 4÷20mA (0÷360°)
DVE-CDVECModel: DVE · Heating: Standard · Output signal: RS485/Modbus, standard ID: 004
DVER-ADVERAModel: DVER · Heating: Heated (Pw<5W) · Output signal: 0÷2Vdc (0÷360°)
DVER-BDVERBModel: DVER · Heating: Heated (Pw<5W) · Output signal: 4÷20mA (0÷360°)
DVER-CDVERCModel: DVER · Heating: Heated (Pw<5W) · Output signal: RS485/Modbus, standard ID: 004
Shopping Basket