Dimetix DPE-30-500 Laser Distance Sensor | up to 500 m
- Manufacturer: DIMETIX AG
- Category: Displacement, SENSORS, Laser distance sensors, Level Sensors, Level sensors for solids
Dimetix DPE-30-500, reference 500636. Long-range industrial laser rangefinder for non-contact measurement of distance, position, displacement, or level. Range: from approximately 0.05 m to 100 m directly on natural surfaces and up to 500 m with suitable reflective sheeting.
Applications: machine positioning, overhead cranes, stacker cranes, structural monitoring, steelmaking and level measurement in solids.
Industrial applications of the DPE-30-500 laser rangefinder
To determine a distance or position without contact, with the target several meters from the sensor or in motion.
Common applications:
- Positioning of overhead cranes and gantry cranes.
- Control of cars, rails and mobile machinery.
- Stacker elevators, shuttles and automated warehouses.
- Measurement of position and displacement in large structures.
- Monitoring of bridges, tunnels and civil works.
- Control of coils, plates and materials in steelmaking.
- Length and position measurement in production lines.
- Level measurement in silos, hoppers and solid storage.
- Control of distance between equipment or moving elements.
Optical measurement has no mechanical contact with the object being measured, so there is no wear and tear and it can be used to measure on moving targets or hard-to-reach areas.
Measurement range: up to 100 m without reflector and 500 m with reflector
On natural surfaces: from 0.05 m approximately 100 m. With suitable reflective sheeting: approximately 500 m under favorable conditions.
The actual range depends on the surface and measurement conditions. Color, reflectivity, target geometry, ambient light, and atmospheric conditions can all influence the strength of the signal received by the sensor.
- Light and matte surfaces usually offer better measurement conditions.
- Dark surfaces can reduce the available range.
- Shiny or specular surfaces can cause unwanted reflections.
- Dust, fog, rain, or snow can affect long-range measurements.
- To achieve maximum distances, an appropriate reflector must be used.
Accuracy, measurement speed, and moving targets
The DPE-30-500 offers a typical accuracy of ±3 mm at 2σ and a typical repeatability of ±0.7 mm at 2σ under average conditions.
Maximum measurement frequency: 250 optical measurements per second, even in dynamic applications and on moving targets.
In the specific mode for moving targets, the maximum refresh rate depends on the interface used:
- Up to 250 Hz via serial interfaces.
- Up to 500 Hz via Industrial Ethernet.
- Up to 1 kHz via SSI, analog output or certain digital outputs.
It's important to distinguish between the measurement frequency and the output update frequency. A 1 kHz output doesn't mean the rangefinder performs 1,000 independent optical measurements per second; the maximum measurement frequency is 250 Hz.
PLC connection: 4-20 mA, RS485, SSI and Industrial Ethernet
Interfaces for PLCs, control systems, data acquisition and industrial automation:
- Programmable analog output: 0-20 mA or 4-20 mA.
- RS-232.
- RS-422 / RS-485.
- SSI.
- Programmable digital input.
- Programmable digital outputs.
- Error signaling output.
- USB for configuration.
Optionally, it can be equipped with industrial Ethernet communications via an interchangeable cover:
- PROFINET.
- EtherNet/IP.
- EtherCAT.
The presence of RS-485 does not mean the device uses Modbus RTU natively. Serial communication is handled by Dimetix's proprietary ASCII protocol.
Outdoor use and demanding environmental conditions
IP65 protection. Operating temperature: -40 to +60 °C. Suitable for indoor and outdoor installation.
In long-distance measurements, atmospheric conditions must be taken into account, since temperature, pressure, humidity, rain, fog or dust can influence the propagation of the laser beam and the quality of the received signal.
In facilities with high thermal radiation, such as steel mills or foundries, it must be verified that the sensor's temperature remains within its operating limits. Thermal shields, protective housings, or cooling systems may be used when necessary.
Frequently Asked Questions and Dimetix Model Replacement
Can the DPE-30-500 measure up to 500 meters without a reflector?
No. Over natural surfaces, the range is up to approximately 100 m. To reach distances close to 500 m, it is necessary to use a suitable reflective sheet over the lens.
What is the difference between the DPE-30-500 and the DPE-10-500?
The DPE-30-500 and models DPE-10-500 They share the same maximum range, a measurement frequency of up to 250 Hz, and the main communication interfaces.
The main difference lies in the accuracy:
- DPE-30-500 / 500636: typical accuracy ±3 mm.
- DPE-10-500 / 500630: typical accuracy ±1 mm.
If the application requires accuracy close to ±1 mm, the DPE-10-500 is the model to consider. When accuracy of ±3 mm is sufficient, the DPE-30-500 maintains the same maximum reach and speed performance as the rest of the DPE range.
Can the DPE-30-500 replace the old DPE-30-150 / 500631?
The DPE-30-150, reference 500631, belongs to an earlier generation of the Dimetix D Series. The current DPE-30-500 / 500636 is one of the models that can be considered when replacing this unit.
Both operate with a typical accuracy of ±3 mm and reach measurement frequencies of up to 250 Hz, while the DPE-30-500 extends the available range with reflector to approximately 500 m.
Before making a replacement, the configuration, connections, interface used, and parameters of the original installation must be checked.
Which older Dimetix models can be considered for replacement?
In addition to the DPE-30-150, there are several previous generations of Dimetix rangefinders and distance sensors that can still be found installed in industrial machinery and facilities.
References from previous equipment:
- DLS-C 30 / Part No. 500621
- DLS-CH 30 / Part No. 500623
- FLS-C 30 / Part No. 600501
- FLS-CH 30 / Part No. 600503
The choice of replacement should be made by checking the range, accuracy, measurement speed, wiring, and communication protocol used by the installed sensor.
Are there any other special references for Dimetix sensors?
Dimetix has also manufactured special variants that are not part of the current standard catalog. Among the identified references are:
- SP1912403 / Part No. 500646
- SP20051501 / Part No. 500648
- SP20081901 / Part No. 500649
- SP606013P
- DP3230202P
These references should not be considered direct equivalents to the DPE-30-500. To determine its replacement, it is recommended to check the nameplate, serial number, connections, and interface used.
To identify the configuration, the equipment label and connections are needed.
Does the DPE-30-500 have RS485 or Modbus RTU?
The DPE-30-500 features RS-422/RS-485, in addition to RS-232 and SSI. Communication via RS-485 uses Dimetix's proprietary ASCII protocol and does not natively support Modbus RTU.
What is the difference between a measurement of 250 Hz and an output of up to 1 kHz?
The DPE-30-500 can perform up to 250 optical measurements per second. In moving target mode, certain interfaces can update their output at a higher frequency, reaching up to 1 kHz.
Therefore, a 1 kHz output does not equate to 1,000 independent optical measurements per second.
Can the DPE-30-500 be used to measure levels in silos?
Yes. The rangefinder can measure the distance to the surface of the material and use that value to calculate the available level in silos, hoppers, or solid storage tanks.
It can be used on materials such as aggregates, grain, biomass, sand or scrap metal, bearing in mind that suspended dust, geometry and surface characteristics may affect the range and stability of the measurement.
How do I identify a replacement for an old Dimetix sensor?
The simplest way is to check the model, part number, and serial number indicated on the equipment label. It's also advisable to know the interface used, the measuring distance, and the required accuracy.
Without original documentation, the installed reference is studied from photographs of the nameplate and the sensor connections.
Information needed to select a Dimetix laser rangefinder or replace an older model: measurement distance, required accuracy, surface type, and communication interface. For an installed unit: photograph of the label and connections.
Properties
| DIMETIX DPE-30-500 TECHNICAL SPECIFICATIONS | |
|---|---|
| Model / Reference | DPE-30-500 / 500636 |
| Sensor type | Long-range industrial laser distance sensor |
| Measurement principle | Non-contact optical distance measurement |
| Range on natural surfaces | 0.05…approximately 100 m |
| Range with reflective sheeting | Approximately 0.5 … 500 m |
| Typical accuracy at 2σ | ±3 mm, under average conditions |
| Typical accuracy at 1σ | ±1.5 mm |
| Typical repeatability at 2σ | ±0.7 mm |
| Typical repeatability at 1σ | ±0.35 mm |
| Minimum unit shown | 0.1 mm |
| Maximum measuring speed | 250 Hz |
| Maximum output speed | Up to 1 kHz in moving target mode, according to the interface |
| Maximum speed of the target | Up to 10 m/s in moving target mode and good measurement conditions |
| Light source | Visible red laser diode, 620 … 690 nm, typically 655 nm |
| Laser class | Class 2, power less than 1 mW |
| Typical laser spot size | 7 x 3 mm at 10 m / 28 x 13 mm at 50 m / 55 x 30 mm at 100 m |
| Analog output | 0-20 mA or 4-20 mA, programmable |
| Analog output resolution/error | 12 bits / ±0.1 % of programmed span |
| Communication interfaces | RS-232, RS-422/RS-485 and SSI |
| RS-422 / RS-485 Protocol | Dimetix ASCII protocol, addressable IDs 0 … 99 |
| USB | Included, exclusively for configuration |
| Optional Industrial Ethernet | PROFINET, EtherNet/IP or EtherCAT via interchangeable cover |
| PROFIBUS | Available via optional external converter |
| Digital entry | 1 programmable input |
| Digital outputs | 2 programmable NPN, PNP or Push-Pull outputs and 1 error output |
| Feeding | 12 … 30 VDC |
| Power consumption at 24/12 VDC | 0.5 A / 0.8 A, not considering loads connected to the outputs |
| Operating temperature | -40 … +60 °C |
| Temperature with industrial Ethernet | Maximum +50 °C |
| Storage temperature | -40 … +70 °C |
| Relative humidity | Up to 85 % RH, non-condensing |
| Degree of protection | IP65 according to IEC 60529 |
| Shock and vibration tests | IEC 60068-2-27 / IEC 60068-2-6 |
| Housing material | EN-AW 6060 anodized aluminum alloy |
| Electrical connection | Internal screw terminals |
| Dimensions | 140 x 78 x 48 mm |
| Weight | 350 g |


Related documentation, cases, and guides
Technical documentation
- How a laser distance meter measures: time of flight
- Dimetix FLS-C: Laser distance measurement in dynamic positioning
- Dimetix: Comparison table of 8 laser distance sensors
- Level measurement in silos with the Dimetix EDS-C laser sensor
- Dimetix laser sensors in cutting and machining: length measurement
- Dimetix laser sensors in metallurgy: steel ingots, presses and bars
Use cases