Linear Cable Transducer F600C
- Manufacturer: ELCIS Encoder
- Category: Displacement, SENSORS, Linear Cable Transducer, Linear Transducers
The ELCIS F600C is an absolute wire linear transducer, with 0.51 mm diameter wire and CANopen output, for measuring linear displacements up to 6 meters.
The electronics incorporate ASIC photodiodes with a 100,000-hour LED light source, a CAN transceiver (ISO 11898), status indication with 2 LEDs, and SMD technology. It is protected against reverse polarity and overvoltages, with an unbreakable encoder disc and EMC certification according to EN 50081-2 and EN 61000-6-2.
Encoder and mechanics IP64; the output IP rating depends on the connection: cable gland (3PG, 3PG-VA, 2M20) IP65, 5-pin round connectors (1BW, 2BW) or fiber optic connector (1HW). 98% humidity (non-liquid state). Operating temperature -20 to +70 °C and storage temperature -40 to +85 °C. Weight 1.4 kg depending on the stroke.
- Max. standard stroke 6 meters and resolution of 0.1 mm either 1 mm.
- Interface CANopen either CAN fiber optic with programmable parameters (rotation direction, resolution, preset value, cams, speed, baud rate and CAN identifier).
- Thread of stainless steel Ø 0.51 mm and average lifespan of the transducer >10⁶ cycles at 2 m/s.
- Maximum linearity error of ±0.05 % fs., max. read speed of 4 m/s and max. acceleration of 2.5 G.
- Encoder IP64; cable glands IP65 (3PG, 3PG-VA, 2M20).
Technical Frequently Asked Questions
What communication interface does the F600C transducer have?
(C2) CANopen / CAN with CAN transceiver (ISO 11898), or (CF) CAN fiber optic.
What career paths and resolutions does it offer?
Standard max. stroke of 6 meters, with resolutions of 0.1 mm (code 100) and 1 mm (code 1000) and binary output code.
What level of protection and connections does it have?
Encoder and mechanics IP64; cable glands 3PG, 3PG-VA and 2M20 are IP65 and connectors 1BW, 2BW and 1HW are available. The IP rating of the outlet depends on the connection.
Properties
| Feature | Specification |
|---|---|
| Mechanics | |
| Max standard stroke. | 6 m |
| Weight | 1,4 kg (depending on the career) |
| Race: traction thread | Ø 0.51 mm stainless steel |
| Race: forces on the cable | Exit 20 N · Return 10 N |
| Race: max speed / acceleration. | 4 m/s / 2.5 G |
| Electric | |
| Resolution / Exit Code | 0,1 mm, 1 mm · Binary |
| Maximum linearity error. | ±0.05 % fs. |
| Feeding and max. consumption. | 10÷30 V CC · 2.5 W |
| Output interface | (C2) CANopen / CAN · (CF) CAN Optical Fiber |
| Protection and environment | |
| Transducer average lifespan | >10⁶ cycles at 2 m/s |
| Impact/vibration resistance | 30 G (11 ms) / 10 G (10 ÷ 1000 Hz) |
| Operating/storage temperature | -20 ÷ +70 °C / -40 ÷ +85 °C |
| Humidity | 98 % (without liquid state) |
| Degree of protection | Encoder and mechanics: IP64 · Cable gland: IP65 · Outlet: according to connection (IP in accordance with CEI EN 60529, EN 60529, IEC 529 standards) |
| Reference | Configuration |
|---|---|
| F600C-B-1000-1030-3PGF600CB100010303PG | Binary output code · 1 mm resolution · 10–30 V DC · 3 cable glands · IP65 |
| F600C-B-100-1030-3PGF600CB10010303PG | Binary output code · 0.1 mm resolution · 10–30 V DC · 3 cable glands · IP65 |
| Other combinations of resolution, power supply, electronics and connection are available upon request: please contact us and we will confirm the exact reference. | |