Explosion-proof Incremental Encoder I/0Q80EXS
- Manufacturer: ELCIS Encoder
- Category: Encoder, Incremental Encoder, ATEX Explosionproof Incremental Encoder, SENSORS
The ELCIS 0Q80EXS (I/0Q80EXS) is an explosion-proof incremental encoder with a □80 square flange and a Ø10 h7 shaft, with a capacity of 1 to 10,000 pulses per revolution. It is designed for working environments with explosive atmospheres of gas «G» and dust «D», excluding firedamp mines, and is ISSeP certified according to CENELEC standards, with markings II 2 G Ex d IIC T6 Gb and D Ex tb IIIC T85°C Db IP6X (T5: T100°C) according to EN60079-0, EN60079-1 and EN60079-31, within the ISSeP07ATEX018X certificate notified by CESI02ATEX138Q. Its output electronics include NPN, PNP, push-pull, 26LS31 and 88C30 drivers, TTL, discriminator, and 1 Vpp sinusoidal output, available in unidirectional, bidirectional, and zero-channel versions. The output cable is permanently connected.
Marked II 2 G Ex d IIC T6 Gb and D Ex tb IIIC T85°C Db IP6X (T5: T100°C) according to EN60079-0, EN60079-1 and EN60079-31, with ISSeP07ATEX018X certificate notified by CESI02ATEX138Q.
NPN, PNP, push-pull output electronics, 26LS31 and 88C30 drivers, TTL, discriminator and 1 Vpp sinusoidal output, in unidirectional, bidirectional and zero channel versions. Permanently connected output cable.
- Square flange □80, casing Ø80 and stainless steel shaft Ø10 h7.
- Ambient temperature -20 to +60 °C on T5 and -20 to +40 °C in T6.
- 1 to 10000 pulses per lap and up 100 kHz (300 kHz optional).
- IP65 on the axis side (IP66 with sealed bearing) and 6000 rpm continuous (3000 rpm with sealing).
- Nutrition 5 to 30 V according to the version.
Technical Frequently Asked Questions
What is the difference between the T5 and T6 versions?
In T6 (standard) the maximum surface temperature of the housing is 85 °C and the ambient temperature is -20 to +40 °C; in T5, it's 100 °C surface and -20 to +60 °C ambient. The unbreakable disc (option Y) is only available in T6.
How do you connect the cable in an explosive atmosphere?
The encoder uses a cable rated for at least 100°C, permanently connected. The connection must be made to an Ex junction box or outside of a potentially explosive atmosphere; the cable end connector is only permitted outside of explosive atmospheres. Special conditions for safe use (symbol X): mounting screws must be of grade 8.8 or higher.
Can it be used in mines with firedamp?
No. It is built for use in all locations except firedamp mines.
Properties
| Feature | Specification |
|---|---|
| Mechanics | |
| Flange | Square, □80 mm |
| Housing | Ø80 mm |
| Weight | 1300 g |
| Axis | Ø10 h7 stainless steel (customizable upon request) |
| max radial/axial load. | 10 kg |
| Electric | |
| Exit-side protection | IP66 cable • IP65 cable end connector |
| Feeding | 5–30 V (see feeding table) |
| Max. consumption. | 120 mA Standard · 180 mA line driver (customizable upon request) |
| Impulses per lap | 1 to 10000 |
| Max frequency. | 100 kHz (300 kHz optional) |
| Protection and environment | |
| axle-side protection | IP65 standard · IP66 sealed (Z) |
| max. continuous RPM | 6000 standard · 3000 sealed (intermittent: +30 %) |
| Impact resistance | 50 G × 11 ms |
| Vibration resistance | 12 G (10–2000 Hz) |
| Room temperature (ATEX) | T5: -20 … +60 °C · T6: -20 … +40 °C |
| Reference | Configuration |
|---|---|
| I/0Q80EXS5-50-824-BK-VM-R-01I0Q80EXS550824BKVMR01 | 50 pulses/revolution · 8–24 V · bidirectional · NPN open collector · Cable with standard 7c connector · radial output |