DPK210-xxx

Illuminance sensor, lux meter, measuring range: 0-2000lux / 0-20klux / 0-200klux

DPK210 series sensors (LUXOMETER) are very sensitive, can detect weak light and has a wide measuring range.
It is suitable for most applications, especially in agricultural greenhouses, urban lighting, solar plants and weather stations.
Measuring range: 0-2000lux / 0-20klux / 0-200klux
Output signal: 0-5V, 0-10V, 4-20mA, RS485

Properties

What is illuminance (lux)?
Lux provides information about illuminance. It is a measure of the brightness with which an area is illuminated. Lux indicates the amount of luminous flux (lumen) from a light source that reaches a receiver per unit area. The lux value is a purely receptor-related quantity.

Illuminance is calculated using the following formula: Lux [lx] = luminous flux [lm] / surface [m2]

Illuminance is 1 lux when a luminous flux of 1 lumen falls uniformly on a surface of 1 m². Another formula for calculating illuminance at greater distances is: Lux [lx] = luminous intensity [cd] / radius or distance squared.
A lux meter measures luminance (lux). The value indicates the brightness at the measuring point. The lux meter consists of a photo sensor and electronics that convert the signal into a tractable value.
Sunlight can reach a value of 50,000 Lx.

Link to the manufacturer's website

Other products

DPF Sensors
Universal 2-way galvanic converter/isolator. Input: 0…500 mV, 0…700 V, (solar spatial up to 1500 V) / 20 mA, PWM. Multiple output: 0/10 V (0/5 V DC) and 0-4/20 mA.
DPF Sensors
AMPER-O-RS, AC/DC (TRMS) to RS485 Modbus + 0/10V current transformer, with isolation, high precision. 0…25…50 A
DPF Sensors
2-way universal galvanic isolator/converter. 4 channels, Input: 4/20 mA (Active/Passive), Output: 0-10 VDC, Power supply: 10-30 VDC
DPF Sensors
LVDT displacement sensor, pencil type, diameter 8 mm, repeatability better than 1 micron, ranges 2.5, 5 and 10 mm.
B&C Electronics
pH sensor for range 0 to 13pH with 9m cable. Double ring junction.
Differential pressure switch for air
DPF Sensors
High-precision AC/DC (TRMS) current transformer to 4/20mA current loop, with isolation. 0/150A – 0/300A – -150/+150A – -300/+300A
DPF Sensors
Three-phase voltage monitoring relay. Overvoltage, undervoltage, and sequence
DPF Sensors
Industrial inclinometer. Range 10º to 360º, 1 and 2 axes, Output signal 0.5-4.5 Vdc / 4…20 mA, CAN / RS485/ TTL / 422, Power supply 9…36 Vdc, IP67, Working temperature -40…+85ºC, accuracy ±0.2º
Non-intrusive ultrasonic transit time meter for pipes from 15 to 6000 mm