AEFM-001 Atmospheric Electric Field Meter

Early lightning warning | −100 … +100 kV/m | 3 s response time | 3 alarm levels | Modbus RS-485 | 6061 aluminum, Ø78 × 105 mm

For lightning monitoring and early warning, the DPF Sensors AEFM-001 is an atmospheric electric field meter that measures in real time the electric field variations associated with lightning activity.

It measures from -100 to +100 kV/m with a response time of 3 seconds and transmits the field strength value in V/m, rotational speed, and alarm level via Modbus RS-485. It has three configurable thresholds: 3, 8, and 10 kV/m by default. When the field exceeds a threshold, the alarm level rises to 1, 2, or 3.

It is used in weather stations (providing reference information for sectors such as aviation and maritime operations), petrochemical plants, communications base stations, electrical installations, high-rise buildings, agriculture, and forestry. The housing is made of 6061 aluminum alloy, measuring Ø78 × 105 mm, and connects with a 4-wire shielded cable. Available in guemisa.es.

  • Range of −100 to +100 kV/m with a response time of 3 s.
  • 3 alarm levels with thresholds of 3, 8 and 10 kV/m by default, modifiable via Modbus.
  • Modbus RS-485 with speeds of 2400 to 115200 and default address 245.
  • Consumption of 0.8 W at 12V and motor life of up to 4000 h without overloading or blocking.

Technical Frequently Asked Questions

How does the AEFM-001 generate the lightning alert?

It compares the measured electric field with three thresholds, 3, 8, and 10 kV/m by default. When the field exceeds a threshold, the alarm level register (0x0008) is set to 1, 2, or 3. The thresholds are modified by writing to registers 0x000A, 0x000C, and 0x000E.

How is the electric field read by Modbus?

Using function 03 on register 0x0006, which is 4 bytes, the value is in V/m, with one decimal place by default. The default address is 245 and the transmission speed is chosen in register 0x0004, between 2400 and 115200.

How do I connect the AEFM-001?

With a shielded 4-wire cable: red, power; blue, GND; green, 485B; yellow, 485A. The specifications indicate 12V DC (0.8W at 12V) and the cable color code, 12~24V DC: please confirm with Guemisa before ordering.

Properties

FeatureSpecification
Extent
Measuring range-100 … +100 kV/m
Precision±0.001 % FS.
Response time3 s
Reading the field In V/m, with one decimal place by default
Alarm levels3 / 8 / 10 kV/m default, configurable thresholds
Food and communication
Feeding12 V DC 0.8 W at 12 V; 12~24 V DC depending on the wiring (confirm with Guemisa before ordering)
CommunicationModbus RS-485
Default address245
Transmission speed2400 … 115200 2400, 4800, 9600, 19200, 38400 or 115200
Wire 4 shielded wires: red +, blue GND, green 485B, yellow 485A
Mechanics and environment
Rotation speed≥ 50 rpm in normal operation
Engine life4000 h at most, without overload or blocking
Housing material 6061 Aluminum Alloy
DimensionsØ78 × 105 mm dimensions 75 mm and Ø38 mm
Facility Protect from impacts, high temperatures and freezing; ensure watertightness
DPF Sensors AEFM-001 Atmospheric Electric Field Meter
DPF Sensors AEFM-001 Atmospheric Electric Field Meter Dimensional Drawing

Other products

NESA Environmental Meters
Humidity and temperature sensor
LOGO TORQUE CERTIFICATION
Strain Gauges (DMS) | 50 – 10,000 N·m | Stationary Standard | PCD Flanges 84.0 – 196.0 mm
B&C ELECTRONICS Logo 2026 WATER QUALITY
Antimony combined reference pH electrode with epoxy body, size 75x12. with 9m cable for the galvanic industry.
B&C ELECTRONICS Logo 2026 WATER QUALITY
Combined glass/gel reference pH electrode, epoxy body 1.5m cable with BNC. Low cost
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
25 mm linear resistive sensor • ball joint coupling • 2 m cable • ±0.002 mm repeatability
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
ATEX II 2 GD | Ex d IIC T6 / T5 | Hollow shaft Ø10 H7 stainless steel | Internal coupling | 1 to 10000 pulses/revolution | Max. frequency 100 kHz | Power supply 5–30 V | IP65 shaft side (IP66 sealed) | 6000 rpm continuous | Ambient temp. -20…+40 °C (T6)
Compact ultrasound stations, RS485 ModBus communication
LOGO TORQUE CERTIFICATION
Steady Reaction Transducer | 30,000 – 50,000 N·m | 0 RPM | PCD Flange 290.0 mm | Base Inertia 0.5695 kg·m²
Pressure switch
Disibeint Electronic, manufacturer of level sensors and control relays
HYPALON ECO LEVEL SWITCH
Shopping Basket