BAR-AV Precision Digital Barometer
- Manufacturer: Nesa
- Category: Meteorology – Climatology, Pressure, Atmospheric pressure, SENSORS
The NESA BAR-AV is a precision digital barometer for absolute pressure, QNH, QFE, and QFF, with a capacitive transducer (1 to 3), IP67 painted metal enclosure, and WMO and ICAO standards. Typical measurement range 500–1200 hPa and accuracy ±0.15 hPa at +20°C.
Modbus RS485, Modbus TCP/IP (EthL LAN) and RS232 auto-transmission outputs, with web interface and display. References: BAR-AV (one transducer) and BAR-AV-S (three transducers). For AWOS stations, airport meteorology, aviation and navigation, and industrial and environmental monitoring.
Key points
- Typical measurement range 500÷1200 hPa, resolution 0.01 hPa, time constant ~ 2 s
- Accuracy ±0.15 hPa at +20°C; ±0.20 hPa from -40 to +60°C; long-term stability <±0.1 hPa/year
- Linearity and hysteresis < ±0.1 hPa, overpressure limit 3000 hPa
- Modbus RS485, Modbus TCP-IP, RS232 auto forwarding, socket, FTP
- 10.8÷15Vdc, <0.9 W (~ 45 mA @ 12Vdc), reverse polarity and transient protection
- IP67, -40 ÷ +80°C (screen -20 ÷ +60°C), ~ 700 g, 200 x 110 x 60 mm
Technical Frequently Asked Questions
What measurement principle does the BAR-AV use?
It uses a capacitive principle absolute pressure transducer (1 to 3), automatically temperature compensated by a 3D algorithm.
What is the difference between BAR-AV and BAR-AV-S?
The BAR-AV has one transducer and the BAR-AV-S has three. Both include a calibration report and a 2.5 m cable.
How can the data be accessed?
Data can be accessed via the instrument's own web pages (numerical and graphical format, without external software), RS232 (automatically sending every 1 second), RS485 Modbus, TCP/IP Modbus, socket, or FTP. Internal memory stores one to three years of data in ASCII or CSV format.
Properties
| Feature | Specification |
|---|---|
| Measurement and operating principle | |
| Measured magnitude | Absolute pressure, QNH, QFE, QFF |
| Measurement principle | Capacitive, temperature compensated with 3D algorithm |
| Transducers | 1 (BAR-AV); 3 (BAR-AV-S) |
| Typical measurement range | 500÷1200 hPa |
| Linearity | < ±0.1 hPa |
| Hysteresis | < ±0.1 hPa |
| Resolution | 0.01 hPa |
| Accuracy at +20°C | ±0.15 hPa |
| Extended total accuracy | ±0.20 hPa (-40…+60 °C) |
| Calibration uncertainty | ±0.25 hPa |
| Time constant | ~ 2 s |
| Long-term stability | <±0.1 hPa/year |
| Overpressure limit | 3000 hPa |
| Regulatory compliance | EC; CIMO/ET-Stand-1/Doc.10 (20.XI.2012) WMO-2012; WMO and ICAO |
| Output signals and interface | |
| Exit sign | Modbus RS485; Modbus TCP-IP, Lan Eth; auto send RS232, socket, FTP |
| RS232 Auto-Send | Every 1 second |
| Web interface | Configuration and display in numeric and graphical format via the 10/100 MBps LAN port (in addition to the keyboard), without external software |
| Internal memory | One to three years of data, in ASCII or CSV format |
| QNH and QFF temperature | Standard (15 °C) or actual air temperature, with sensor connected |
| Power supply, environment, and mechanical data | |
| Feeding | 10.8÷15Vdc |
| Consumption | <0.9 W (~45 mA @ 12Vdc) |
| Protections | Polarity reversal and transients |
| Operating conditions | -40 ÷ +80°C [0÷100 RH]; display: -20 ÷ +60°C |
| Envelope | Painted metal, IP67 |
| Connectors | Two IP68 resin connectors: one 4-wire and one 7-wire |
| Dimensions | 200 x 110 x 60 mm (see drawing) |
| Weight | ~ 700 g |
| Calibration | Calibrated and verified in a climate chamber; 3D matrix calibration system on standard primary reference; calibration report valid for one year from the first active configuration |
| Supply configuration | Calibrated, tested, and configured for continuous transmission over RS232 |
| Reference | Configuration |
|---|---|
| BAR-AVBARAV | Transducers: 1 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable |
| BAR-AV-SBARAVS | Transducers: 3 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable |