LU06 Ultrasonic Level Sensor

Budget-friendly price Request a quote
Piezoelectric Ultrasound 65 kHz | 0÷6 m | 0.1 % fs @ 20°C | 4÷20mA | 10.8÷30 Vdc | IP66 | 180 x 162 mm

The NESA LU06 is an ultrasonic hydrometer or snow level sensor with a piezoelectric transducer housed in a screen that protects it from direct sunlight and wind gusts. It is used as a hydrometer and snow gauge, with automatic temperature compensation.

Typical range 0–6000 mm with a 300 mm dead zone, sensitivity 1 mm, accuracy 0.1% fs @ 20°C (ΔT < 2%), response time < 1 s, and operating frequency 65 kHz. Output 4–20 mA (LU06-B), power supply 10.8–30 Vdc, IP66 aluminum housing.

Key points

  • Typical range 0÷6000mm; dead zone 300mm
  • Sensitivity 1 mm; accuracy 0.1% fs @ 20°C (∆T < 2%); response time < 1s
  • Piezoelectric transducer, working frequency 65 kHz; automatic temperature compensation
  • 4÷20mA output; with MCS module (optional) RS485 ModBus
  • Power supply 10.8÷30 Vdc, consumption < 1.2 W (measured); protections against reverse polarity and transients
  • Operating conditions -25 ÷ +70°C; aluminum body IP66; 330g; CE

Technical Frequently Asked Questions

What is its range and accuracy?

Typical range 0÷6000mm with a dead zone of 300mm. Accuracy 0.1% fs @ 20°C (∆T < 2%) and sensitivity 1 mm.

What kind of outlet and power supply does it have?

4÷20mA output (LU06-B), with MCS module (optional) RS485 ModBus. Power supply 10.8÷30 Vdc, consumption < 1.2 W (measured).

What level of protection does it have?

IP66 aluminum body, with protection against reverse polarity and transients.

Properties

FeatureSpecification
Measurement and operating principle
Measured magnitudeHydrometric or snow level
Transducer typePiezoelectric
Typical range0÷6000mm
Dead zone300mm
Sensitivity1 mm
Accuracy0.1% fs @ 20°C (∆T < 2%)
Response time< 1s
Operating frequency65 kHz
Temperature compensationAutomatic
Regulatory complianceEC
Exit signals
Output signal (LU06-B)4÷20mA
With MCS module (optional)RS485 ModBus
Power supply, environment, and mechanical data
Feeding10.8÷30 Vdc
Consumption< 1.2 W (in measurement)
Operating conditions-25 to +70°C
ProtectionsAgainst polarity reversal and transients
BoxAluminum body IP66
Weight330g
ReferenceConfiguration
LU06-BLU06BRange: 0–6 m · Output: 4–20 mA · Supply: With calibration report
NESA LU06 Ultrasonic Level Sensor
Dimensions of the NESA LU06 ultrasonic level sensor

Other products

NESA Environmental Meters
Up to 3 simultaneous ions | Depth 0.2 ÷ 20 m | Electrodes with ±1100mV output | RS485 | 12 Vdc (10.8 ÷ 16Vdc) | 500×42 mm (L x D) | PVC
NESA Environmental Meters
K-band radar <25GHz | 0÷20 m | 0.01% fs (±2 mm) | 4÷20mA | Current loop or 10÷28 Vdc | IP66 – IP68 (0.2 bar) | 285 x 72 mm
NESA Environmental Meters
Visual reading | From one meter | ±1 cm | Anti-corrosion painted aluminum | High-visibility yellow, black numerals | 1000 x 150 x 50 mm | 3 kg per linear meter
NESA Environmental Meters
Piezometric capsule | 0–5 to 0–50 m H2O | < 0.2% fs or better | 4–20 mA | Current loop or 10–28 Vdc | 316 stainless steel | PUR cable
NESA Environmental Meters
Piezometric capsule, NTC | 0–20 bar | -5–+80 °C | <0.5% fs or better | 2 x 4–20 mA | Current loop or 10–28 Vdc | 316 stainless steel
Encardio Rite vibrating wire sensors and geotechnical instrumentation
Vibrating wire piezometer for pore pressure (interstitial water pressure) and groundwater level | Ranges 0.2 to 10 MPa | Accuracy ±0.25 % FS
Dimetix_AG-1
Dimetix DBN-50-050 industrial laser sensor for distance and position measurement up to ~50 m on natural surfaces, with typical accuracy ±5.0 mm @2σ (±2.5 mm @1σ), frequency up to 10 Hz and analog output 0/4-20 mA.
Disibeint Electronic, manufacturer of level sensors and control relays
CONDUCTIVE ELECTRODES WITH BUILT-IN AMPLIFIER
Disibeint Electronic, manufacturer of level sensors and control relays
CONDUCTIVE ELECTRODES WITH BUILT-IN AMPLIFIER
Shopping Basket