EPP-30V Piezometer

Vibrating wire piezometer for pore pressure (interstitial water pressure) and groundwater level | Ranges 0.2 to 10 MPa | Accuracy ±0.25 % FS

Vibrating wire piezometer for pore pressure and geotechnical instrumentation

He EPP-30V Heavy Duty Vibrating Wire Piezometer Encardio Rite is a pore pressure sensor designed for measuring the interstitial water pressure and the control of water table in applications of geotechnical instrumentation, Civil works, mining and hydraulic infrastructure.

This piezometer for geotechnical monitoring It uses vibrating wire technology to convert applied pressure into a frequency signal, enabling stable and reliable measurements in installations with long cable runs and demanding environments. It is a suitable solution for projects requiring continuous monitoring of water behavior in the ground.

EPP-30V Vibrating Wire Piezometer for Geotechnical Monitoring

The model EPP-30V It is designed to offer long-term durability and stability under real-world field conditions. Its robust construction, vacuum-sealed design, thermal compensation, and integrated thermistor make it a suitable choice for buried applications and automated data acquisition systems.

What is a pore pressure sensor used for?

A pore pressure sensor It is used to monitor pore water pressure in soils, fills, retaining structures, and underground works. This information is key to evaluating the hydraulic behavior of the ground, soil consolidation, and the stability of geotechnical infrastructure.

  • Dams and hydraulic structures: control of the groundwater line, subpressures and water behavior in the ground.
  • Slopes and hillsides: monitoring of interstitial pressure conditions that may affect stability.
  • Tunnels and excavations: control of the groundwater level and the hydraulic behavior of the terrain.
  • Foundations and consolidation: monitoring pore pressure dissipation processes in soft soils.
  • Wells and boreholes: monitoring of groundwater levels.

Advantages of the vibrating wire piezometer

  • Stable long-term measurement in geotechnical monitoring applications.
  • Good signal integrity in installations with long cable distances.
  • Compatibility with dataloggers and data acquisition systems.
  • Robust construction for harsh civil engineering and mining environments.

Keys to a correct installation

The reliability of a vibrating wire piezometer It does not depend solely on the sensor, but also on proper installation based on the terrain, depth, and construction conditions.

  • Filter saturation: necessary to avoid delays in response.
  • Correct range selection: depending on depth and expected pressure.
  • Cable protection: against humidity, mechanical damage and interference.
  • Integration with datalogger: for manual campaigns or continuous monitoring.

Properties

Technical characteristics of the EPP-30V piezometer

FeatureWorth
ModelEPP-30V
Sensor typeVibrating wire piezometer
Measured magnitudePore pressure (interstitial water pressure) and water table
Available ranges0.2 / 0.35 / 0.5 / 0.7 / 1.0 / 1.5 / 2.0 / 3.5 / 5.0 / 10.0 MPa
Precision±0.25 % FS standard / ±0.1 % FS optional
Linearity±0.5 % FS
Allowable overload150 % of the range
Operating temperature-20 to 80 °C
Temperature compensated0 to 80 °C
ThermistorYSI 44005 or equivalent (3 kOhms at 25°C)
Insulation resistance> 500 MΩ at 12 V
HousingStainless steel, with optional salt spray protection
Electrical connectionGlass-to-metal cable connector
Dimensions42 x 185 mm
EPP-30V heavy duty piezometer, Encardio pore pressure, groundwater level
EPP-30V piezometer schematic, parts connection, installation, vibrating wire sensor

Other products

Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Power supply 5-30V | Shaft diameter 6-10mm | Weight 550g | Bearing life 1.5 x 10^9 revolutions | Impact resistance 50G x 11ms | Vibration 12G (10-2000Hz) | Operating temperature 0-70°C | Pulses/rev 1-2540 | Max frequency 60kHz | Output Push-Pull/NPN
Wall humidity and temperature sensor
LOGO TORQUE CERTIFICATION
Driving Telemetry | Stepped Range 50 – 400 N·m | Class Accuracy ±0.10% | Analog Output ±10V | 16-Bit Resolution
B&C ELECTRONICS Logo 2026 WATER QUALITY
Measuring range 0-4,000/40,00/400,0/4,000NTU High chemical resistance
B&C ELECTRONICS Logo 2026 WATER QUALITY
Self-cleaning turbidimeter, Measuring range 0-4,000/40,00/400,0/4,000 NTU
Industrial pressure transducer
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
I/115R – Incremental Encoder Ø 115 mm, solid shaft Ø 11 mm × 31 mm, robust metal body, resolution up to 25,000 dpi
LOGO TORQUE CERTIFICATION
Dual Inductive Metrology | Limit 3000 N·m | 16,000 RPM | PCD Flange 130.0 mm | Accuracy 0.05% | Inertia 0.0092 kg·m²
Industrial resistive displacement sensor, range from 50 mm to 1250 mm
Shopping Basket