KELLER LEO-Record Digital Pressure Gauge with Data Logging
The KELLER LEO-Record is a digital pressure gauge with data logging designed to autonomously measure, display and store pressure and temperature over extended periods. It combines the precision of an industrial digital pressure gauge with the functionality of a datalogger, allowing you to document hydraulic tests, control water networks, detect pressure losses and analyze the behavior of installations without needing to keep a computer permanently connected.
The equipment is available in ranges starting from -1…3 bar to 0…1000 bar, as well as capacitive versions for low pressures of 0…30, 0…100 and 0…300 mbar. In piezoresistive versions it offers an accuracy of up to ±0.05 % of the full scale and a total error band of up to ±0.1 % FS between 0 and 50 °C.
Its internal non-volatile memory can store up to 57,000 pressure and temperature measurements with date and time stamp. The logs are configured and downloaded using the RS485 interface and the free KELLER PressureSuite Desktop software.
Digital pressure and temperature recording manometer
The LEO-Record doesn't just display instantaneous pressure. Its recording function allows you to track how pressure evolves over minutes, hours, days, or weeks. This capability is especially useful when a single reading doesn't allow you to identify pressure drops, operating cycles, leaks, nighttime variations, or intermittent behavior of a system.
Once configured, the pressure gauge can operate autonomously thanks to its internal 3.6V lithium battery. The storage interval is configurable from 1 second to 99 days, Therefore, it can be adapted to both relatively quick tests and long-term monitoring.
The recording function can be started or stopped manually using the two front pushbuttons. It can also be programmed from PressureSuite to start immediately, on a specific date, or when a pressure-related condition is met.
High precision for industrial applications
The piezoresistive versions of the KELLER LEO-Record provide accuracy up to ±0.05 % FS at an ambient temperature of 20…25 °C. This specification includes nonlinearity, hysteresis, lack of repeatability, and deviations from the zero point and amplification.
The total error band is up to ±0.1 % of the full scale within the compensated range of 0…50 °C. This value represents the maximum error considering both pressure and temperature simultaneously, thus providing a more realistic reference for the instrument's behavior under working conditions.
Capacitive versions are available for low pressures. These versions cover ranges of 0…30, 0…100, and 0…300 mbar and offer an accuracy of up to ±0.1 % FS and a total error band of up to ±0.2 % FS between 0 and 50 °C.
Internal memory for up to 57,000 records
The pressure recorder has non-volatile memory, so the stored values are retained even if the equipment is switched off or the battery is replaced.
- Up to 57,000 values with date and time when the measurement interval is equal to or less than 15 seconds.
- Up to 28,000 values with date and time when the measurement interval is greater than 15 seconds.
- Minimum storage interval: 1 second.
- Maximum interval configurable via software: 99 days.
- Recording of pressure and temperature channels.
- Configurable memory in linear mode or circular ring memory.
In linear mode, recording stops when the memory is full. In ring storage mode, older values can be overwritten with new measurements, ensuring that the most recent data is always available.
Interval and event-driven recording
PressureSuite Desktop allows you to adapt the datalogger's operation to each application. In addition to regular recording at constant intervals, LEO-Record can initiate recording when a specific event occurs.
- Periodic recording at constant intervals.
- Start when the pressure exceeds a configured value.
- It starts when the pressure drops below a certain value.
- It starts when a pressure variation is detected.
- Combination of continuous recording and event-driven recording.
- Immediate start or scheduled for a specific date and time.
- Calculation of the average of a configurable number of measurements.
These functions allow you to reduce the amount of unnecessary data and focus the recording on the relevant moments of the process.
Clear reading and operation via two pushbuttons
The LEO-Record features an LCD screen with two rows of five digits. The top row shows the current pressure value and the bottom row indicates the recorder status.
- run: Registration is active.
- PrEP: The team is waiting for the scheduled start condition.
- End: The recording has ended.
- BAT LOW: low battery warning.
- OFL / UFL: value higher or lower than the range that the screen can display.
The SELECT and ENTER buttons allow you to turn the instrument on, select units, start or stop recording, and adjust the zero point. It is also possible to restore the factory zero setting.
Pressure can be displayed in bar, mbar, hPa, kPa, MPa, psi, mH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, and kp/cm². Additionally, up to five user-defined units of measurement can be configured via the software.
PressureSuite Desktop and RS485 communication
The digital pressure gauge incorporates an interface RS485 half-duplex. To connect it to a computer, an RS485-USB converter is used; the KELLER accessory is recommended. K-114A with the corresponding connector.
The free KELLER PressureSuite Desktop software for Windows allows you to:
- Configure the pressure and temperature channels.
- Select the measurement and storage interval.
- Schedule the start and conditions of the registration.
- View the measured values in real time.
- Graphically represent the stored data.
- Check the range, serial number, and firmware version.
- Calibrate the zero pressure point.
- Configure the water level calculation.
- Export data in CSV, JSON, Excel, Word, and image formats.
RS485 communication also allows the LEO-Record to be integrated into custom applications. KELLER provides protocol documentation, a DLL library, and programming examples for developers and integrators.
Applications of the digital pressure gauge with datalogger
The LEO-Record is suitable for applications where it is necessary to measure and document pressure over time:
- Hydraulic tests and leak tests.
- Monitoring of pipes and water supply networks.
- Leak detection and analysis.
- Control of pressure groups and pumping stations.
- Supervision of tanks and hydraulic systems.
- Checking line pressure in gas pipes.
- Control of compressed air installations.
- Preventive maintenance of industrial machinery.
- Pressure testing and quality control.
- Pressure monitoring in oil reservoirs.
- Water level analysis based on hydrostatic pressure.
To record extremely rapid transients or pressure spikes, the required acquisition frequency must be checked beforehand. The LEO-Record is specifically designed for long-term, periodic monitoring, with a minimum storage interval of one second.
Robust construction for industrial use
The equipment has protection IP65 and pressure connections made of stainless steel. In the piezoresistive versions, the sensor diaphragm is made of AISI 316L stainless steel. For ranges above 400 bar, AISI 318LN stainless steel, material 1.4462, is used in the pressure connection.
The standard connection is G 1/4 male and a connection is also available 1/4-18 NPT male. Other connections, special ranges, fluid contact materials, and specific configurations can be supplied upon request.
The screen can be rotated approximately 180° to the left or right relative to the sensor, making it easier to read once mounted. Rotation should be performed according to the manufacturer's instructions to avoid damaging the internal wiring.
Nutrition and autonomy
The LEO-Record is powered by a lithium battery of 3.6V type SL-760. The estimated battery life is approximately two years under continuous operation with a ten-second storage interval. Actual battery life depends on measurement frequency, interface usage, and operating conditions.
The standard version also supports an external power supply of 8…28 VCC. After replacing the battery, the device must be reconfigured using the software to properly update the internal clock and logging parameters.
ATEX and IECEx version
A specific model is available for installations in potentially explosive atmospheres. LEO-Record-Ei, with intrinsic safety and ATEX and IECEx certifications.
The LEO-Record-Ei version is certified Ex II 2G Ex ia IIC T4 Gb. In this implementation, only the authorized Tadiran SL-760 lithium battery may be used. External power is not permitted, and the RS485 interface must not be used within the explosion-risk area.
The standard LEO-Record version is not ATEX. For applications in classified areas, the LEO-Record-Ei must be expressly requested and the conditions of use indicated in its certificate and manual must be checked.
Accessories and options available
- K-114A RS485-USB Interface Converter.
- Protective rubber cover for demanding environments.
- Carrying case with belt loop.
- KELLER 5-point calibration certificate.
- KELLER 11-point calibration certificate.
- Pressure connection G 1/4 or 1/4-18 NPT.
- Versions for relative, absolute and differential pressure.
- Special versions for low pressures.
- Ranges and special materials available upon request.
- Intrinsically safe version LEO-Record-Ei.
How to select the right LEO-Record
To prepare a quote and correctly select the equipment, please tell us the pressure range, the type of pressure —relative, absolute or differential—, the required connection, the process fluid, the expected recording interval and whether you need the K-114A USB converter or a calibration certificate.
You must also specify whether the pressure gauge will be installed in a safe area or in a potentially explosive atmosphere. Our technical department can help you choose the most suitable range and configuration for your application.
Frequently Asked Questions about the KELLER LEO-Record
What is the difference between a digital pressure gauge and a digital pressure gauge with data logging?
A conventional digital pressure gauge displays the current pressure. The LEO-Record also stores pressure and temperature values with date and time, allowing for later analysis of how the system has changed.
How much data can it store?
It can store up to 57,000 timestamped values when the interval is equal to or less than 15 seconds. When the interval is greater than 15 seconds, the capacity is 28,000 values.
What is the minimum recording interval?
The minimum storage interval is one second. Using PressureSuite, an interval of up to 99 days can be configured.
How are the records downloaded?
Data is downloaded via the RS485 interface. To connect the pressure gauge to a USB port, it is recommended to use the KELLER K-114A converter and the PressureSuite Desktop software.
Is the USB converter included?
The K-114A converter is an accessory and must be expressly included in the offer when required. The LEO-Record does not have a direct USB connection.
Is there a version for ATEX zones?
Yes. The LEO-Record-Ei is the intrinsically safe version specifically designed for explosive atmospheres. It must be selected specifically; the standard LEO-Record is not ATEX certified.
Properties
| General information | |
|---|---|
| Product | Digital pressure gauge with data logging |
| Manufacturer | KELLER Pressure |
| Model | LEO-Record |
| Recorded variables | Pressure and temperature |
| Ranges and features | |
| Piezoresistive ranges | From -1…3 bar to 0…1000 bar |
| Capacitive ranges | 0…30, 0…100 and 0…300 mbar |
| Types of pressure | Relative, absolute or differential depending on the version |
| Piezoresistive accuracy | ≤ ±0.05 % FS at 20…25 °C |
| Total error band | ≤ ±0.1 % FS between 0…50 °C, piezoresistive version |
| Capacitive accuracy | ≤ ±0.1 % FS at 20…25 °C |
| Capacitive error band | ≤ ±0.2 % FS between 0…50 °C |
| Long-term stability | ≤ ±0.1 % FS/year under reference conditions |
| Temperature measurement | ±1 °C typical |
| Reserved range | ±10 % |
| Data logger | |
| Maximum memory | 57,000 values with date and time for intervals ≤15 s |
| Intervals greater than 15 s | 28,000 values with date and time |
| Recording interval | Configurable from 1 second to 99 days |
| Record types | Periodic, scheduled or event-driven |
| Memory management | Linear storage or circular memory |
| Display and operation | |
| Screen | LCD, 2 rows of 5 digits |
| Display | Pressure and status of the record |
| Screen update | 2 measurements per second, according to recording configuration |
| Units | bar, mbar, hPa, kPa, MPa, psi, mH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg and kp/cm² |
| Zero adjustment | From push buttons or via software |
| Communication and software | |
| Interface | RS485 half-duplex |
| Computer connection | Via RS485-USB converter K-114A, accessory |
| Software | KELLER PressureSuite Desktop for Windows, free license |
| Export | CSV, JSON, Excel, Word, image and other formats |
| Feeding | |
| Battery | Lithium 3.6V, type SL-760 |
| Guiding autonomy | Approximately 2 years with recording every 10 seconds |
| External power supply | 8…28 VDC, standard version only |
| Construction and environmental conditions | |
| Pressure connection | G 1/4 male or 1/4-18 NPT male |
| Diaphragm material | AISI 316L stainless steel, piezoresistive version |
| Exterior gasket | FKM, 75 Shore |
| Protection | IP65 |
| Medium temperature | -40…85 °C |
| Ambient temperature | -10…60 °C, standard version |
| Storage temperature | -20…70 °C |
| Piezoresistive dimensions | Approx. Ø76 × 125 × 54 mm, without cover |
| Approximate weight | 250g without case / 350g with case |
| Version for explosive atmospheres | |
| ATEX / IECEx version | LEO-Record-Ei optional |
| Marked | Ex II 2G Ex ia IIC T4 Gb |
| Certificates | PTB 05 ATEX 2012 X / IECEx PTB 13.0028 X |
| ATEX Note | The standard version is not ATEX compliant. The Ei version does not support external power or RS485 use within the explosive atmosphere. |
| Accessories | |
| Optional | K-114A, rubber cover, carrying case, and 5 or 11 point calibration certificates |
Specifications may vary depending on the range, pressure type, and selected configuration. Consult GUEMISA to determine the appropriate part number.


Other products