µV, 0÷2Vdc, 4÷20mA, RS485/Modbus | 0 ÷ 2000 W/m² | 0.3 ÷ 3 µm | Class B (ISO 9060) | 255 x 162mm | IP67

The NESA RSG1 is a first-class thermopile pyranometer (class B according to ISO 9060) for measuring global solar radiation between 0.3 and 3 µm using the cosine law. It is WMO compliant for environmental monitoring and suitable for photovoltaic applications according to IEC 9060 and IEC 17025.

Measurement range from 0 to 2000 W/m², typical sensitivity of 10 µV/(W/m²), zero offset < 14 W/m², response time < 20 seconds, expected daily uncertainty < 5%. Double quartz glass dome (K5), IP67 aluminum housing, and natural output in µV, 0÷2Vdc, 4÷20mA or RS485 / Modbus.

Key points

  • First class (class B) according to ISO 9060; compliant with WMO
  • 0 ÷ 2000 W/m², 0.3 ÷ 3 µm, 10 µV/(W/m²)
  • Zero offset < 14 W/m² (at 200 W/m²), stability < ±1.5% per year, non-linearity < ±1%
  • Outputs µV, 0÷2Vdc, 4÷20mA or RS485 / Modbus (ID 003)
  • Anodized aluminum, IP67, -40 ÷ +80 °C, < 630 g

Technical Frequently Asked Questions

What outputs does the RSG1 pyranometer have?

RSG1-N: natural thermopile, 10 µV/(W/m²). RSG1-A: 0÷2Vdc = 0…2000 W/m². RSG1-B: 4÷20mA = 0…2000 W/m², not powered by the loop. RSG1-C: RS485 / Modbus RTU (9600 baud, N, 8, 1; function 0x03; registers 40002 – 40003; standard ID 003).

What makes the RSG1 different?

It is first class: zero offset < 14 W/m², stability < ±1.5% per year, non-linearity < ±1% and expected daily uncertainty < 5%, with double quartz glass dome (K5).

How do I order it?

Sensor (RSG1), output (A, B, C or N), sensor-datalogger cable (05, 10 or xx, length in meters to be specified) and support (SS1 of l = 500 mm, SS2 of l = 900 mm or SS3 of l = 1500 mm). Manufacturer's example: RSG1 A 10 SS2.

Properties

FeatureSpecification
Measurement and operating principle
Measured magnitudeGlobal solar radiation (cosine law)
Measurement range0 ÷ 2000 W/m²
Spectral range0.3 µm ÷ 3 µm (AM1.5G)
Typical sensitivity10 µV/(W/m²) over 2π sr
Typical output constant10 mV/(kW/m²)
Resolution< 4 W/m²
Response time< 20 s
Zero offset< 14 W/m² (at 200 W/m²); < ±3 W/m² (ΔT = 5 K/h)
Long-term stability (1 year)< ±1.5%
Cosine response< ±16 W/m²
Temperature response (ΔT 50 K)< 4%
Nonlinearity< ±1 %
Response to tilt (0 – 90°)< ±2%
Expected daily uncertainty< 5%
TransducerThermopyle
ClassificationFirst class (class B according to ISO 9060)
Regulatory complianceISO 9060; WMO; CE
Output signals and interface
Output (version N)10 µV/(W/m²), direct from thermopile
Output (version A)0÷2Vdc = 0…2000 W/m²
Output (version B)4÷20mA = 0…2000 W/m², not powered by the loop
Output (version C)RS485 / Modbus RTU (Half duplex); Standard ID 003; 9600 baud, N, 8, 1; Function 0x03; Registers 40002 – 40003 (IEEE754 32 bits)
Output impedance< 40 Ω
CalibrationBy comparison with a primary standard instrument of superior class and known constant
Power supply, environment, and mechanical data
Food and consumptionSelf-powered in the N version; 10 ÷ 30Vdc < 0.1 W in the others
ProtectionsProtection against short circuits and lightning strikes
Operating conditions-40 to +80 °C
Degree of protectionIP67
MaterialAnodized aluminum and stainless steel screws
Dimensions255 x 162 mm (see drawing)
Weight< 630 g
ReferenceConfiguration
RSG1-ARSG1AModel: RSG1 · Output signal: 0÷2Vdc · Supplied with: Calibration report
RSG1-BRSG1BModel: RSG1 · Output signal: 4÷20mA · Supplied with: Calibration report
RSG1-CRSG1CModel: RSG1 · Output signal: RS485 / Modbus (Standard ID 003) · Supplied with: Calibration report
RSG1-NRSG1NModel: RSG1 · Output signal: Natural in µV (10 µV/(W/m²)) · Supply: With calibration report
NESA RSG1 First Class (Class B) Pyranometer
Dimensions and connections of the NESA RSG1 pyranometer

Other products

Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø6–10 mm | Housing Ø72 mm | 1 to 25000 imp/revolution | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP64 shaft (IP66 sealed) | Star-shaped, compensates ±1 mm axial
Encardio Rite vibrating wire sensors and geotechnical instrumentation
Vibrating wire extensometer for measuring deformations in concrete and steel
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Magnetostrictive | Stroke 50 … 4250 mm | Incremental A/B/Z, RS422 | Resolution 1 or 5 µm | Linearity ≤ ±25 … ±120 µm | 13 … 34 VDC | IP67 / IP68
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Square flange 92 mm | Ø90 mm, hollow shaft Ø20 H6 | 9000–900000 imp/rev | Driver 26LS31 or 1 Vpp | 5 V ±5 % | IP64 shaft (IP65 output with cable) | ±5″; 2200 kHz with interpolation
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
IO-Link | Ø 48 mm | 14-bit resolution | Shaftless: magnetic placeholder | 24 VDC (18 … 30 VDC) | IP67 / IP68 / IP69 | Single channel
B&C Electronics – Italian manufacturer of industrial water sensors and analyzers
Cell content K=1cm-1 (2 to 2,000µS) Thread 1″ BSP, body material polypropylene
Monitran-Logo
1100 pC/g ±10% | -55 to 250 °C | ±100 g | Integrated TNC connector | Stainless steel, IP65 | Requires charge amplifier
Disibeint Electronic, manufacturer of level sensors and control relays
CONDUCTIVE ELECTRODES WITH BUILT-IN AMPLIFIER
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Through shaft Ø6, 8, 10, 12 or 15 mm | Housing Ø59 mm | 1 to 50000 imp/revolution | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP64 shaft (IP65 Z-seal) | Elastic coupling