RFC-4800 IO-Link Non-Contact Angle Sensor
Novotechnik RFC-4800 IO-Link Non-Contact Angle Sensor. Non-contact Hall angle sensor, up to 360°, in two mechanically decoupled parts.
Non-contact Hall angle sensor, in two parts: sensor and magnetic position marker, without shaft or bearing. 360° measuring range. IP67, IP68, and IP69 protection. Measures through non-ferromagnetic material. Encapsulated electronics.
Key points
- Contactless Hall technology, electrical range up to 360°
- Two-piece design, mechanically decoupled
- IP67, IP68, IP69 protection
- 14-bit resolution
- Unlimited mechanical life
- Other configurations are available in separate data sheets.
Technical Frequently Asked Questions
What can be connected to the RFC-4800 IO-Link contactless angle sensor?
It can be connected to Novotechnik M12 connectors and cables and Novotechnik rotary sensor positioners (magnets).
How do I order the RFC-4800 IO-Link contactless angle sensor?
The order code has six fields: mechanical version, digital interface, resolution, interface, parameters, and connection. For example, RFC-4852-214-A11-252 is the version with round hole mounting, digital interface, 14 bits, IO-Link with one clockwise incrementing position, and a 1 m unshielded 4-pole cable. All the options for each field are available in the order code configurator on this page.
Under what conditions does the RFC-4800 IO-Link contactless angle sensor operate?
Operating temperature: -40 … +105 °C, -25 … +85 °C (M12 connector). Protection: IP67 / IP68 / IP69, IP67 (M12 connector).
Properties
| Feature | Specification |
|---|---|
| Measurement and interface | |
| Measured variables | Position (other process data, such as speed, revolution counter or cams, on request) |
| Measuring range | 360° |
| Number of channels | 1 |
| Protocol | IO-Link Spec V1.1 according to IEC 61131-9, Smart Sensor Profile (compatible with V1.0) |
| Programmable parameters | Zero point displacement, averaged, direction of rotation |
| Diagnosis | Activated (in case of error, the output signal falls outside the plausible signal range) |
| Position resolution (in 360°) | 14 bits |
| Update frequency (output) | 1 kHz |
| Transmission speed | COM 3 (230.4 kBaud) |
| Type of plot | 2,2 |
| Minimum cycle time | 1 ms |
| Independent linearity | ≤ ±0.5 % FS |
| Repeatability | ≤ ±0.1° |
| Hysteresis | ≤ ±0.1° |
| Temperature error | ±0.2 % FS |
| Feeding and protection | |
| Supply voltage Ub | 24 VDC (18 … 30 VDC) |
| No-load current consumption | ≤ 50 mA |
| Reverse polarity protection | Yes (feed lines) |
| Short circuit protection | Yes (output to GND and supply voltage up to 40 VDC) |
| Overvoltage protection | 35 VDC (permanent) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Cable section | 0.5 mm² (AWG 20) |
| Electromagnetic compatibility | |
| EN 61000-4-2 ESD (contact/air discharge) | 4 kV, 8 kV |
| EN 61000-4-3 Electromagnetic fields (RFI) | 10 V/m |
| EN 61000-4-4 Fast transients (burst) | 2 kV |
| EN 61000-4-6 Conducted disturbances (HF fields) | 10 V ef. |
| EN 55016-2-3 Radiated disturbances | Industrial and residential area |
| Environmental conditions | |
| Vibration IEC 60068-2-6 | 20 g, 5 … 2000 Hz, Amax = 0.75 mm |
| IEC 60068-2-27 Shock | 50 g, 6 ms |
| DIN EN 60529 protection | IP67 / IP68 / IP69, IP67 (M12 connector) |
| Working temperature | -40 … +105 °C, -25 … +85 °C (M12 connector) |
| Life | Mechanically unlimited |
| MTTF (IEC 60050) | 810 years |
| Mechanical data | |
| Housing | Temperature-resistant plastic |
| Fixation | 2 M4x20 socket head cap screws (included in the supply) |
| Mechanical tour | Continuous |
| Maximum working speed | Mechanically unlimited |
| Weight (without connection) | approx. 50 g |
| Electrical connection | 4x 0.5 mm² (AWG 20) TPE cable, unshielded / M12x1 connector, A coding, with cable L = 0.15 m |
| Option | Meaning |
|---|---|
| Example: RFC-4852-214-A11-252 = mounting with round hole, digital interface, 14 bits, IO-Link with 1 clockwise increasing position and 1 m unshielded 4-pole cable. | |
| 1 · Mechanical version | |
| 4851 | Mounting with elongated hole |
| 4852 | Mounting with round hole |
| 2-5 · interface, resolution, bus interface, interface parameters | |
| 2 | Interface: Digital interface |
| 14 | Resolution: 14 bits |
| TO | Bus interface: IO-Link |
| 11 | Interface parameters: 1x position, increasing clockwise |
| 6. Electrical connection | |
| 252 | 4-pole cable, unshielded, L = 1 m |
| 256 | 4-pole cable, unshielded, L = 3 m |
| 260 | 4-pole cable, unshielded, L = 5 m |
| 270 | 4-pole cable, unshielded, L = 10 m |
| 551 | Unshielded 4-pin M12x1 connector with cable, L = 0.15 m |
| The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference. | |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications
Other products