Chione Frost Alert Control Unit

Budget-friendly price Request a quote
Dry and wet bulb temperature | Humidity 0 ÷ 100% RH | SigFox, LoRa/NESA, GSM/GPRS | Lithium battery, rechargeable or 5W panel | -40 ÷ +60°C | IP65 | ~455 x 300 mm

The NESA Chione unit is a monitoring device for detecting microclimatic conditions that can lead to late frosts in crops, whether from radiation or advection. The most important parameter to monitor is the wet-bulb temperature, the air temperature resulting from evaporative cooling under and within the foliage. Data is available in the cloud via a web interface or a mobile app.

Dry-bulb temperature -40°C to +60°C and wet-bulb temperature -20°C to +50°C, both with an accuracy of ±0.3°C and a resolution of 0.05°C; humidity 0 to 100% RH, ±2%, 0.2%. SigFox coverage up to 15 km and LoRa/NESA up to 8 km, GSM/GPRS depending on operator availability in the area. Die-cast aluminum housing, IP65 rated, -40 to +60°C.

Key points

  • Dry bulb temperature 1 and 2: -40°C ÷ +60°C, ±0.3°C, 0.05°C; wet bulb temperature 1 and 2: -20°C ÷ +50°C, ±0.3°C, 0.05°C
  • Humidity 1: 0 ÷ 100 %RH, ±2%, 0.2%
  • Transmission frequency 860 ÷ 920MHz – programmable or quad-band (GSM/GPRS) for different countries
  • Radio coverage: SigFox up to 15km, Lora/NESA up to 8km, GSM/GPRS depending on operator availability in the area
  • Transmission protocols: SigFox, LoRa/Lora-WAN, proprietary, TCP/IP socket, MQTT
  • Standard data transmission rate of 15 minutes; at temperatures below 5°C, 5 minutes
  • Power supply: 1 x 3.3V 8000mA non-rechargeable C2 type lithium battery, or rechargeable battery from power bank, mains or external mini solar panel (2000mA)
  • Operating temperature -40 ÷ +60°C; die-cast aluminum IP65; ~455 x 300mm; <2Kg; CE

Technical Frequently Asked Questions

What coverage and protocols does it have?

SigFox up to 15km, LoRa/NESA up to 8km, GSM/GPRS depending on operator availability in the area. Protocols: SigFox, LoRa/LoRa-WAN, proprietary, TCP/IP socket, MQTT.

How often does it transmit data?

The standard rate is 15 minutes; at temperatures below 5°C, it drops to 5 minutes. The data is available in the cloud via a web interface or app.

How does it feed?

With 1 x 3.3V 8000mA non-rechargeable C2 type lithium battery, or with rechargeable battery (2000mA) from power bank, mains or external mini solar panel.

Properties

FeatureSpecification
Product and data
Product typeControl unit for frost alert in plants
Historical dataHistorical database always available
Sensors: range, accuracy, and resolution
Dry bulb 1 (range)-40°C ÷ +60°C
Dry bulb 1 (accuracy)±0.3°C
Dry bulb 1 (resolution)0.05°C
Dry bulb 2 (range)-40°C ÷ +60°C
Dry bulb 2 (accuracy)±0.3°C
Dry bulb 2 (resolution)0.05°C
Humidity 1 (range)0 ÷ 100 %HR
Humidity 1 (accuracy)±2%
Humidity 1 (resolution)0,2%
Wet bulb 1 (range)-20°C ÷ +50°C
Wet bulb 1 (accuracy)±0.3°C
Wet bulb 1 (resolution)0.05°C
Wet bulb 2 (range)-20°C ÷ +50°C
Wet bulb 2 (accuracy)±0.3°C
Wet bulb 2 (resolution)0.05°C
Transmission
Transmission frequency (Hz)860 ÷ 920MHz – programmable or quad-band (GSM/GPRS) for different countries
Radio coverageSigFox up to 15km, Lora/NESA up to 8km, GSM/GPRS depending on operator availability in the area
Transmission protocolsSigFox, LoRa/Lora-Wan, Proprietary, Socket TCP-IP, MQTT
Data transmission rate (standard)15 min
Transmission rate at temperatures below 5°C5 min
Cloud dataAvailable via web interface or APP
Power supply, environment, and mechanical data
Non-rechargeable lithium battery1 x 3.3V 8000mA type C2
Rechargeable batteryFrom power bank, mains or external mini solar panel (2000mA)
Working temperature-40 to +60°C
Box materialDie-cast aluminum, for outdoor use
Protection classIP65
Dimensions~455 x 300mm (excluding the mast)
Weight<2Kg
Regulatory complianceEC
NESA Chione Frost Alert Control Unit
Dimensions of the NESA Chione frost alert control unit

Other products

Dimetix_AG-1
Industrial laser sensor for measuring up to ~100 m directly on natural surfaces and up to 150 m with reflector, with ±1 mm @2σ and up to 100 Hz.
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø10, 12, 14, 15 or 20 mm | Housing Ø72 mm | 1 to 25000 imp/revolution | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP64 shaft (IP66 Z-seal) | Compensation ±3 mm axial, ±2°
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Voltage divider | Stroke 10 … 300 mm | Linearity ±0.05 … ±0.25 % | Repeatability ≤ ±0.01 mm | 42 V max. | IP54 | Cable or M8 connector
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Servo flange Ø38 mm, shaft Ø6.35 h7 | 8192 steps/revolution (13 bits) | SSI (RS422), natural binary | Power supply 5 V, 5–30 or 10–30 V | IP64 shaft (IP66 sealed) | 12000 rpm with low torque (option B) | Impacts 100 G (6 ms)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Adjustable metal supports | Stroke 50–900 mm | 5 kΩ (≤600 mm), 10 kΩ (≥750 mm) | Potentiometric output (divider) | Max. power supply 60 V | IP60 (IP65 with option 3) | DIN 43650 connector
NESA Environmental Meters
2 data channels | Surge protection | DIN rail | 4÷20mA, 0÷2V, 0÷5V, Pt100 | 500A (10/350µs) | -40÷+85°C | IP20
LVDT Manufacturer Logo Schreiber Messtechnik
Microcontroller-based LVDT | 5 to 15 mm range | M30x1.5 and 25x25 mm housings | IP67/IP66 | Scalable outputs | Threaded/lock mounting
B&C Electronics – Italian manufacturer of industrial water sensors and analyzers
Combined glass/gel reference pH electrode, epoxy body, size 75x12. with 1.5m BNC cable.
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Voltage divider | Ø 50.8 mm | Shaft Ø 6 mm (or Ø 6.35 mm) | Ub max. 42V | IP40 | 355° ±2, linearity ±0.05 %
Shopping Basket