TX2 with Novotechnik clamps | Linear position sensor

Potentiometric linear position sensor with adjustable clamp mounting, travels from 25 to 300 mm and IP67 protection

He TX2 with clamps Novotechnik it's a potentiometric linear position sensor Designed to measure the absolute and direct displacement of mechanisms and moving elements. It is available with defined electrical travels of 25, 50, 75, 100, 150, 200, 250 and 300 mm and uses a resistive track made of conductive plastic that works as a voltage divider.

This version of TX2 uses two adjustable clamps for securing the cylindrical body of the sensor. The system allows modification of the mounting position along the Ø 16 mm body and facilitates its integration into machinery, test benches, and mechanisms where the exact position of the fixing points may vary.

The transducer combines a compact design with protection IP67, independent linearity up to ±0.05 % FS According to the path, repeatability ≤ ±0.01 mm, maximum speed of 5 m/s and a typical lifespan of more than 50 million movements.

  • Technology: linear position potentiometric sensor.
  • Defined routes: 25 / 50 / 75 / 100 / 150 / 200 / 250 / 300 mm.
  • Exit: voltage divider, ratiometric signal.
  • Mounting: two adjustable clamps.
  • Body diameter: Ø 16 mm.
  • Independent linearity: up to ±0.05 % FS depending on the route.
  • Repeatability: ≤ ±0.01 mm.
  • Resolution: better than 0.01 mm.
  • Maximum speed: 5 m/s.
  • Protection: IP67.
  • Typical lifespan: over 50 million movements.
  • Connection: 3-pole M8x1 radial connector or 2m shielded radial PUR cable.

Applications of the TX2 linear position sensor with clamps

The adjustable clamp mounting allows the TX2 to be used in applications where linear position or stroke measurement is required, while maintaining freedom to define the sensor body fixing points.

Industrial machinery and automation

  • Absolute measurement of position and displacement.
  • Linear mechanism stroke control.
  • Position feedback in machines and automatic systems.
  • Motion measurement in actuators and mechanical assemblies.
  • Installations in confined spaces thanks to the Ø 16 mm body.

Test benches and measuring systems

  • Position recording during mechanical tests.
  • Simultaneous measurement of displacement with force, pressure, torque, or other variables.
  • Repetitive motion tests and operating cycles.
  • Verification of races and final positions.

Demanding industrial environments

The IP67 protection and the construction with anodized aluminum housing and stainless steel stem allow the TX2 to be used in applications exposed to dust, humidity, oil and dirt, always respecting the assembly conditions indicated by the manufacturer.

Mounting using adjustable clamps

The mechanical execution 717 Identify the TX2 with clamp mounting. Supplied two fixing clamps and two M5x20 screws.

The recommended distance between clamps depends on the selected travel:

  • 25 mm: 30 mm.
  • 50 mm: 50 mm.
  • 75 mm: 70 mm.
  • 100 mm: 90 mm.
  • 150 mm: 140 mm.
  • 200 mm: 190 mm.
  • 250 mm: 240 mm.
  • 300 mm: 290 mm.

The drive stem is rotatable, made of 1.4305 / AISI 303 stainless steel and has an M5 external thread.

When the application may transmit lateral forces or there is misalignment between the sensor shaft and the moving element, Novotechnik recommends using a suitable coupling to avoid lateral loads on the stem.

Potentiometric output and connection to control systems

The TX2 is a linear potentiometric transducer. The resistive element made of conductive plastic acts as a voltage divider and generates a signal proportional to the position of the stem.

It does not include a standard industrial output of 0–10 V or 4–20 mA. When the control system requires one of these signals, a compatible signal conditioner can be used to power the potentiometer and convert the position signal.

According to the path, the nominal resistance value is 1 to 12 kΩ. The recommended current on the cursor should be kept at ≤ 1 µA and the maximum permissible voltage is 42 VDC.

This technology provides an absolute signal: after a power disconnection, the position is obtained directly from the resistive value when power is restored to the circuit, without the need to count pulses or perform a reference search.

M8x1 connector or 2-meter PUR cable

The TX2 with clamps is available with two electrical connection options:

  • Code 101: M8x1 3-pole radial connector.
  • Code 202: 2m radial shielded PUR cable.

Connection assignment

  • Connection 1: pin 1 / BN – brown.
  • Connection 4, signal output: pin 4 / WH – white.
  • Connection 3: pin 3 / GN – green.

The signal increases when the stem is extended when the positive supply is connected to connection 3 and decreases when the positive is applied to connection 1. The position signal is obtained at connection 4.

References and configuration of the Novotechnik TX2 with clamps

The complete reference identifies the path, mechanical execution, resistive element, and connection type.

Example: TX2-0200-717-002-101 corresponds to a 200 mm TX2, clamp-mounted, linearized resistive element and 3-pole M8x1 radial connector.

  • 717: execution with single-sided stem, IP67 protection and mounting by means of clamps.
  • 002: linearized resistive element.
  • 101: M8x1 3-pole radial connector.
  • 202: 2m radial shielded PUR cable.

Full references for each route are included in the specifications table on this page.

Frequently asked questions about the TX2 with clamps
What tours are available?

The TX2 series with clamps is available with defined electrical travels of 25, 50, 75, 100, 150, 200, 250 and 300 mm.

Does the TX2 have a 0–10 V or 4–20 mA output?

Not directly. The TX2 is a potentiometric sensor that functions as a voltage divider. If a standardized 0–10 V or 4–20 mA signal is required, a compatible signal conditioner must be used.

What is the difference between the TX2 with clamps and the TX2 with ball joints?

Both use the same potentiometric principle and are available up to 300 mm. This version secures the body using two adjustable clamps. The version TX2 with ball heads It uses articulated heads that allow compensation for angular misalignments between mounting points.

Can it work in dusty or humid environments?

The sensor has IP67 protection according to DIN EN 60529. To maintain this level of protection in the version with a connector, a complementary connector with an IP67 rating or higher must be used.

Which version should I select?

The following must be defined: the required travel, the available mechanical space, the type of electrical connection, and how the moving element will be coupled to the stem.

TX2 Selection and Configuration

He TX2 with clamps It is especially suitable when a Compact, IP67 rated, linear potentiometric position sensor with adjustable mounting.

To select the reference, the following must be defined:

  • Electrical routing required.
  • Space available for the sensor.
  • Mounting distance between clamps.
  • Version with M8x1 connector or 2m PUR cable.
  • Type of inlet or conditioner used.
  • Environmental conditions and number of cycles expected.

If the assembly requires absorbing angular misalignments between the fixing points, the version may be more suitable. TX2 with ball heads.

Consult our application to select the most suitable route, assembly, and connection.

Properties

NOVOTECHNIK TX2 TECHNICAL SPECIFICATIONS WITH CLAMPS
ModelNovotechnik TX2
Sensor typeLinear potentiometric position sensor/transducer
Assembly execution717 · Mounting using two adjustable clamps
Defined electrical paths25 / 50 / 75 / 100 / 150 / 200 / 250 / 300mm
Electrical Ranges27 / 52 / 77 / 102 / 155 / 205 / 255 / 305mm
ExitVoltage divider · ratiometric signal
Nominal resistance according to travel1 / 2 / 3 / 4 / 6 / 8 / 10 / 12 kΩ
Resistance tolerance±20 %
Independent linearity25 mm: ≤ ±0.2 % FS 50–100 mm: ≤ ±0.1 % FS 150–300 mm: ≤ ±0.05 % FS
Repeatability≤ ±0.01 mm
ResolutionBetter than 0.01 mm
Recommended cursor current≤ 1 µA
Maximum cursor current in case of failure10 mA
Maximum allowable voltage42 VDC
Effective thermal coefficientTyp. 5 ppm/K
Insulation resistance≥ 10 MΩ at 500 VDC
Dielectric strength≤ 100 µA at 500 VAC / 50 Hz
MECHANICAL DATA
HousingAnodized aluminum · Ø 16 mm
StemStainless steel 1.4305 / AISI 303, swivel, M5 external thread
BearingSintered bronze bushing
Resistive elementConductive plastic
CursorPrecious metal multi-strand
Housing length A86 / 111 / 136 / 161 / 224 / 274 / 324 / 374 mm, depending on the travel
Mechanical Engineering B30 / 55 / 80 / 105 / 158 / 208 / 258 / 308mm
Recommended distance between clamps D30 / 50 / 70 / 90 / 140 / 190 / 240 / 290mm
Minimum E dimension15 / 20 / 25 / 25 / 35 / 35 / 35 / 35mm
Weight, version with connector100 / 110 / 120 / 130 / 150 / 163 / 190 / 205g
Weight, wired version120 / 156 / 160 / 177 / 190 / 225 / 250 / 270g
Drive force≤ 5 N at 20 °C
Maximum initial force15 N, depending on temperature and downtime
ENVIRONMENTAL DATA
Maximum speed5 m/s
Vibration, IEC 60068-2-620 g · 5 … 2000 Hz · Amax. = 0.75mm
Shock, IEC 60068-2-2750 g · 6 ms
Degree of protectionIP67 according to DIN EN 60529
Working temperature-40 … +85 °C with connector · -20 … +100 °C with cable
Working humidity0 … 95 % HR, non-condensing
Shelf lifeTyp. > 50 × 106 movements
ELECTRICAL CONNECTION
Code 101M8x1 3-pole radial connector
Code 2022m shielded radial PUR cable
Connection 1Pin 1 · BW / brown
Connection 4 · outputPin 4 · WH / white
Connection 3Pin 3 · GN / green
AVAILABLE NOVOTECHNIK REFERENCES
25 mmTX2-0025-717-002-101 / TX2-0025-717-002-202
50 mmTX2-0050-717-002-101 / TX2-0050-717-002-202
75 mmTX2-0075-717-002-101 / TX2-0075-717-002-202
100 mmTX2-0100-717-002-101 / TX2-0100-717-002-202
150 mmTX2-0150-717-002-101 / TX2-0150-717-002-202
200 mmTX2-0200-717-002-101 / TX2-0200-717-002-202
250 mmTX2-0250-717-002-101 / TX2-0250-717-002-202
300 mmTX2-0300-717-002-101 / TX2-0300-717-002-202
Novotechnik TX2 linear position sensor with clamps, part number TX2-0100-717-002-101
2D technical drawing of the Novotechnik TX2 linear position sensor with clamps and mounting dimensions

Other products

Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
IP67 linear potentiometric sensor with ball joints, 25 to 300 mm travel, and M8 or PUR cable connection. Designed for mobile machinery, cylinders, and industrial displacement measurement.
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Industrial rotary potentiometer of 5 kΩ with continuous 360° rotation and IP65 protection.
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
25 mm linear resistive sensor • ball joint coupling • 2 m cable • ±0.002 mm repeatability
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Novotechnik MUP-110/160 potentiometer signal conditioner. Converts position sensors to 0–10 V, 0–20 mA or 4–20 mA for PLC.
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Potentiometric linear position sensor with adjustable clamp mounting, travels from 25 to 300 mm and IP67 protection
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Novotechnik TRS-0025 Industrial Potentiometric Linear Sensor · Reference 400023271 · Electrical travel 25 mm · Probe with return spring
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Galvanic isolation, teach-in function, and configurable voltage or current outputs
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Linear potentiometric probe sensor • 0…50 mm • spring return • cable output
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Novotechnik TRS-0050 potentiometric linear sensor · reference 400023272 · travel 0…50 mm · M16 connector · spring return
Shopping Basket