Schreiber SM224 – Precision LVDT probe

LVDT probe | Travels 2, 5, 10 and 20 mm | Repeatability 0.15 µm | Clamping Ø8 h6 | Ball guide | External electronics

With a repeatability of 0.15 µm and a ball bearing guidance system, the Schreiber SM224 It is designed for dimensional controls where it is important to repeat the same measurement with very little variation. It is used in verification tools, automatic measuring stations, test benches, and other systems where small movements must be controlled with precision.

The series covers tours of 2, 5, 10 and 20 mm. The probe is fixed by an area of Ø8 h6 and the tip directly follows the movement of the workpiece. The body and shank are made of stainless steel, the guiding mechanism is protected by a Viton bellows, and the contact force of the standard version is approximately 0.7 N in the center of the route.

In addition to the conventional spring-return version, there are variants for Pneumatic actuation, vacuum retraction, and radial cable exit, which facilitates its integration into automatic control stations.

The SM224 signal requires external conditioning electronics. Compatible Schreiber electronics, such as the SM224, can be used for integration into a PLC, data acquisition system, or indicator. Schreiber SM12.

SM224 at a glance

  • Routes: 2, 5, 10 and 20 mm.
  • Repeatability: 0.15 µm.
  • Linearity: <0.5 %; option of 0.25 %.
  • Subjection: Ø8 h6.
  • Guided: precision ball bearings.
  • Nominal strength: approx. 0.7 N.
  • Protection: IP65 with bellows.
  • Operating temperature: +5…+80 °C.
  • Standard cable: PUR, 2 m.
  • Electronics: external conditioning.
How the Schreiber SM224 works

The SM224 works on an inductive principle of half bridge. The movement of the stem displaces a core within the coil system and modifies the electrical signal of the sensor.

External electronics are responsible for exciting the sensor and converting that variation into a signal proportional to the position. For this reason, the final resolution of the system also depends on the signal conditioner and the acquisition equipment used.

Ball bearing guidance keeps the stem moving smoothly and reduces lateral movement that could affect the measurement. This design is especially suited for repetitive measurements and dimensional control applications.

Repeatability, linearity, and resolution

The repeatability of 0.15 µm It indicates the probe's ability to obtain virtually the same result when repeating a measurement under the same conditions.

It should not be confused with the linearity. Schreiber specifies a linearity lower than 0.5 % at 20 °C and has an option of 0,25 %.

The resolution Nor is it the same as repeatability. Since it is a sensor without integrated electronics, the smallest variation that the entire system can detect also depends on the signal conditioner, the analog-to-digital converter, and the acquisition equipment.

probe assembly

The SM224 is fixed by its cylindrical area of Ø8 h6. The tip must be facing the surface to be measured and the displacement of the piece must occur in the same direction as the axis of the probe.

Proper alignment prevents lateral stress on the stem and helps to maintain the repeatability of the assembly.

The tip uses a M2.5 thread, Therefore, it can be replaced with different contact geometries. Schreiber offers standard, spherical, flat, carbide or PEEK tips, measuring rollers, and extensions.

The mounting block can be used to fix the probe. SM906.200, prepared for Ø8 mm.

Comparative control

A common application involves adjusting the system using a master part or a known reference and then measuring the deviations of subsequent parts.

Measurement throughout the entire route

With the appropriate electronics and calibration, the full range of motion can also be used to obtain a signal proportional to the position.

Spring return, pneumatic actuation and vacuum

The way the probe is actuated can be adapted to the operation of the machine or the measuring tool.

Standard version

The spring keeps the tip in contact with the workpiece. The approximate force at the midpoint of the stroke is 0.7 N.

Pneumatic version .P

The option .P It allows the probe to be actuated by compressed air. Schreiber specifies approximately 0.7 N at 0.4 bar and 2.5 N at 1 bar.

It is a suitable solution when the tip needs to approach the workpiece only during the automatic measuring cycle.

Empty version .V

The option .V It allows the stem to be retracted using a vacuum. Schreiber's documentation indicates a range of 0…0.27 absolute bar.

Radial output .R

The option .R It has a side cable exit and facilitates assembly when there is not enough space behind the probe.

Travel and performance according to model
ModelRouteRec. priorRec. posteriorSensitivityRepeatability
SM224.22 mm0.15 mm0.35 mm840 mV/mm0.15 µm
SM224.55 mm0.15 mm0.85 mm825 mV/mm0.15 µm
SM224.1010 mm0.15 mm0.85 mm515 mV/mm0.15 µm
SM224.2020 mm0.15 mm0.85 mm330 mV/mm0.15 µm
Dimensions of the SM224

The clamping diameter remains at Ø8 h6, while the length of the probe changes according to the path.

ModelTOB1B2CD1D2
SM224.243.00 mm13.90 mm11.40 mm3.50 mm9.50 mm9.50 mm
SM224.563.00 mm17.40 mm11.40 mm4.00 mm8.50 mm8.00 mm
SM224.1087.00 mm25.40 mm14.40 mm4.00 mm8.50 mm8.00 mm
SM224.20127.00 mm44.90 mm23.90 mm3.00 mm8.50 mm8.00 mm

The pneumatic, vacuum, and radial outlet versions may have some dimensional variations. The drawing of the selected part number must be checked to design the final support.

Construction and working conditions

The body and stem are made of stainless steel The guide mechanism uses ball bearings. The bellows protects the moving part from dirt and other contaminants present in industrial applications.

The bellows configuration has protection IP65 and can work between +5 and +80 °C.

In applications with a high number of cycles, mechanical alignment, stroke used, speed, and the absence of lateral loads are important factors for the life of the probe.

Conditioning electronics and PLC connection

The SM224 does not include an amplifier. It requires electronics compatible with inductive half-bridge sensors.

One of the options is the Schreiber SM12. Depending on the version selected, it allows you to obtain signals from 0/4–20 mA, ±20 mA, 0–10 VDC or ±10 VDC.

In this way, the probe can be installed only at the point of measurement and the electronics can remain in the electrical panel or next to the acquisition system.

5-pin connector

PinFunction
1 / 5WM/WP Power Supply
3MS Signal
2Test pin; do not connect
4Do not connect
How to choose the SM224 version

The appropriate reference depends on the travel, the required level of linearity, and how the probe should work within the machine or tool.

1. Route

Standard routes are 2, 5, 10 and 20 mm. Whenever possible, it is advisable to choose the shortest route that fully covers the intended movement.

2. Linearity

The series has a 0.5 % version and a 0.25 % option.

3. Drive method

For conventional controls, spring return can be used. In automatic stations, pneumatic actuation or vacuum retraction may be more suitable.

4. Available space

When there is not enough space behind the probe, the version with radial cable exit can be used.

5. Measuring tip

The geometry of the tip should be chosen according to the contact surface. A spherical tip, a flat tip, a larger diameter tip, or a roller tip may be more suitable depending on the workpiece.

6. Electronics

If the measurement is to be sent to a PLC, indicator, or DAQ system, the required signal conditioner and output signal must also be selected.

SM224 References and Options

In current nomenclature, .1 Identify the linearity version 0.25 % and .2 the 0.5 % version.

Route0,25 %0,5 %
2 mmSM224.2.1SM224.2.2
5 mmSM224.5.1SM224.5.2
10 mmSM224.10.1SM224.10.2
20 mmSM224.20.1SM224.20.2

Options

  • .P: pneumatic actuation.
  • .V: vacuum retraction in the available references.
  • .R: radial cable exit.
  • .K7: 7m cable in the available version.

The availability of each option depends on the route and must be confirmed for the specific reference.

SM224 Applications

Dimensional control in production

  • Measurement of heights and thicknesses.
  • Dimension control in machined parts.
  • Checking steps and height differences.
  • Classification of parts according to dimension.
  • Automatic tolerance control.
  • Comparison against a standard piece.

Tools and automatic stations

  • Simultaneous verification of several dimensions.
  • Measurement before and after a machining operation.
  • Position control during assembly processes.
  • 100% % inspection on production lines.
  • Checking the presence and position of components.

Geometry and form

  • Flatness control using multiple probes.
  • Measurement of deviations and deformations.
  • Checking concentricity with the appropriate tooling.
  • Measurement of oscillation or radial variation in rotating components.

Precision optics and scientific instrumentation

  • Alignment of mirrors and optical elements.
  • Measuring small displacements in focusing systems.
  • Useful for centering and adjusting optical components.
  • Calibration benches and precision instrumentation.

Test benches

  • Force-displacement tests.
  • Characterization of springs and mechanisms.
  • Measurement of deformations.
  • Displacement recording along with force, pressure, torque, or other variables.
Accessories and electronics
ReferenceDescription
SM901.224.35-pole connector for SM224.
SM901.224.3.K25-pole connector with 2m cable.
SM901.224.3.K55-pole connector with 5m cable.
SM906.200MB8 mounting block for Ø8 mm.
SM906.300M2.5 carbide tip.
SM907.220Standard tip M2.5.
SM907.222M2.5 spherical tip in carbide.
SM907.224Flat tip M2.5, Ø4.8 mm.
SM907.225Roller measuring M2.5.
SM907.226Flat tip M2.5 in PEEK.
SM907.227Flat tip M2.5, Ø1.5 mm.
SM907.228Flat tip M2.5, Ø10 mm.
SM907.229.10 / .20 / .50Probe extensions of 10, 20 or 50 mm.
SM12Schreiber LVDT Conditioning Electronics.
Frequently Asked Questions about the Schreiber SM224
What is the repeatability of the SM224?

Schreiber specifies a repeatability of 0.15 µm for the 2, 5, 10 and 20 mm travels.

Is the resolution also 0.15 µm?

No. Repeatability and resolution are different concepts. The final resolution depends on the conditioning electronics and the acquisition system connected to the probe.

Can it connect directly to a PLC?

No. The SM224 requires external excitation and conditioning electronics. With a module like the Schreiber SM12 Signals such as 4–20 mA, 0–10 V or ±10 V can be obtained.

What tours are available?

The standard travels are 2, 5, 10 and 20 mm.

What protection does it have?

The bellows configuration offers an IP65 protection rating.

What does the mechanical life of the probe depend on?

It depends primarily on the stroke used, speed, mechanical alignment, lateral loads, and operating conditions. Properly aligned mounting helps reduce wear on the guidance system.

Can the measuring tips be changed?

Yes. The M2.5 connection allows the use of different tips and extensions to adapt the contact to the geometry of the workpiece.

What data does GUEMISA need to select the SM224?

The path, the required linearity, the method of operation, the available space, the geometry of the part, the number of measurement points, and the signal that the control or acquisition system must receive.

Schreiber SM224 Selection

GUEMISA can help you define the travel, linearity, drive, measuring tip, assembly, and electronics more suitable for the application.

If the probe needs to be connected to a PLC or acquisition system, the PLC or acquisition system can also be selected together. Schreiber SM12 suitable for the required signal.

The complete technical specifications are detailed in the Properties table on this sheet.

Properties

SpecificationSchreiber SM224
GuyInductive displacement probe
Electrical principleHalf-bridge inductive
Tours2 / 5 / 10 / 20 mm
Linearity<0.5 % at 20°C; option 0.25 %
Maximum repeatability0.15 µm
Typical repeatabilityApprox. 0.05–0.10 µm depending on path and measurement conditions
ResolutionIt depends on the conditioning and acquisition electronics
SM224.2 Sensitivity840 mV/mm
SM224.5 Sensitivity825 mV/mm
Sensitivity SM224.10515 mV/mm
Sensitivity SM224.20330 mV/mm
Previous tour0.15 mm
Rear route0.35 mm on SM224.2 / 0.85 mm on SM224.5, SM224.10 and SM224.20
Clamping diameterØ8 h6
Guidance systemPrecision ball bearings
Probe forceApprox. 0.7 N at the center of the route
Tip threadM2,5
Stem torsion1st place throughout the entire course
Working temperature+5…+80 °C with bellows
Storage temperature-20…+80 °C
Thermal coefficient<0.01 %/°C
Degree of protectionIP65 with bellows
Mechanical lifeApplication dependent; approx. 10 million cycles under typical conditions
Body and axis materialStainless steel
BellowsViton / fluoroelastomer
Standard cablePUR, 2 m
Integrated electronicsNo
ConditioningExternal electronics for half-bridge inductive sensors
Outputs via air conditioner0/4–20 mA, ±20 mA, 0–10 VDC, ±10 VDC depending on electronics
Standard driveDock
Option .PPneumatic drive
Pressure version .P0.4 bar ≈ 0.7 N / 1 bar ≈ 2.5 N
Option VVacuum retraction, 0…0.27 bar absolute
Option .RRadial cable exit
Optional connector5-pin DIN 45322
Schreiber SM224 high-precision LVDT micro probes with different cable exit options and protective bellows.
Dimensional drawing of the Schreiber SM224 LVDT probe with an 8 mm body

Other products

LVDT displacement sensor, ranges from 10 to 40 mm, with or without probe, with separate electronics.
HIGH temperature transducer
LVDT Manufacturer Logo Schreiber Messtechnik
LVDT Converter | Outputs 0/4-20mA, 0/10VDC, ±10V, ±20mA | DIN Rail, Aluminum Housing, OEM Customizable | Infinite Resolution
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø90 mm | Shaft Ø 12 mm / 15 mm | Operating Temp. 0 – +70 °C | Resolution 2 to 13 bits (4 to 8192 positions) | Max. Load 5 Kg | Max. Frequency 50 kHz | Weight 700 g | Vibration 12 G (10 – 2000 Hz) | Impacts 40 G x 11 ms | 8192 positions | Power Supply 5V to 30V | Protection IP65 | LED Life 100k h
B&C ELECTRONICS Logo 2026 WATER QUALITY
Combined pH electrode with glass body, double ring junction, 0–13 pH range and 1.5 m cable with BNC connector.
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Power supply 5V to 30V | Shaft Ø15÷30mm Stainless Steel | Push-Pull Pro Output | IP65 Protection | Weight 650g | Starting Torque >200 g·cm | Maximum Continuous RPM 1000 | Bearing Life 1.5×10⁹ rev | Impact Resistance 50G | Temperature 0÷70°C
LVDT Manufacturer Logo Schreiber Messtechnik
LVDT probe | Travels 2, 5, 10 and 20 mm | Repeatability 0.15 µm | Clamping Ø8 h6 | Ball guide | External electronics
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
I/90 – Incremental Encoder Ø 90 mm, solid shaft Ø 10 mm or Ø 12 mm, robust metal body, resolution up to 25,000 dpi
B&C ELECTRONICS Logo 2026 WATER QUALITY
Industrial pH electrode with S8 connector and PG13.5 thread compatible with Crison, Hach, Omega and Mettler Toledo