M2CH Sensor Interface Board

Budget-friendly price Request a quote
2 data channels | Surge protection | DIN rail | 4÷20mA, 0÷2V, 0÷5V, Pt100 | 500A (10/350µs) | -40÷+85°C | IP20

The NESA M2CH board is a sensor interface board that expands the TMF datalogger to make sensor wiring more flexible and increase surge protection. A single board acquires and protects two data channels.

It consists of a double sensor connection strip, a double PS/2 DIN connector for direct connection to the TMF datalogger, and a protection stage with gas-filled diodes and varistors, providing dual protection against overvoltages and indirect lightning strikes. Rated discharge current (10/350µs) 500A, rated voltage 25V max, rated current 300mA, operating temperature -40–+85°C, and IP20 rating. It offers protection against overvoltages caused by lightning strikes, such as those used in wind data acquisition (wind turbines).

Key points

  • 2 data channels with a single board; TMF datalogger add-on
  • Gas diodes and varistors; dual level protection against overvoltages and indirect lightning; 500A (10/350µs)
  • Nominal voltage 25V max; nominal current 300mA; -40÷+85°C; IP20
  • Reference voltage of 2V on pin 5, with a minimum load greater than 2K
  • Power supply from the TMF datalogger battery or a separate source via screw terminal; ground connection via faston connector
  • Standard configurations by color label: red 4÷20mA, white 0÷2V, Pt100 and «open collector» max. 1000Hz, blue 0÷5V, yellow sinusoidal

Technical Frequently Asked Questions

What protection does it have?

Gas diode and varistor stage, with dual level protection against overvoltages and indirect lightning strikes. Rated discharge current (10/350µs) 500A.

What signals does it support?

According to the color label: red 4÷20mA to 2 and 4 wires; white 0÷2V, Pt100 and frequency sensor «open collector» max. 1000Hz; blue 0÷5V; yellow sinusoidal sensor.

How does it feed?

Power is supplied from the battery that powers the TMF datalogger or, alternatively, from a separate power supply via screw terminals. Grounding is provided via a faston connector.

Properties

FeatureSpecification
Function and protection
Product typeSensor interface board
Number of channels2 data channels
Complement toTMF Datalogger
Protection stageGas diodes and varistors
Level of protectionDouble level protection against overvoltages and indirect lightning
Nominal discharge current (10/350µs)500A
Nominal voltage25V max
Nominal current300mA
Reference voltage2V precision, on pin 5
Minimum load on pin 5Greater than 2K
Input signals and connections
Color labelIt distinguishes the standard configuration; it usually has the associated channel number printed on it.
Red label4÷20mA 2-wire (loop powered) and 4-wire
White label0-2V, Pt100 and «open collector» frequency sensor»
Blue label0÷5V (0-1V divider)
Yellow labelsinusoidal sensor
Open collector frequency«Max. 1000Hz
0÷5V DividerThe signal is reduced 5 times
Sensor connectionDouble power strip
Connecting to the dataloggerDual PS2 DIN connector, direct connection to the TMF datalogger
Power supply, environment, and mechanical data
FeedingFrom the battery that powers the TMF datalogger
Alternative dietSeparate power supply, via screw terminal
GroundingFaston connector, for effective surge protection
Operating temperature-40 to +85°C
Degree of protectionIP20
FormatDIN rail mounting plate on tray
ReferenceConfiguration
M2CH.BM2CHBLabel: Blue · Version for: 0÷5Vdc, 0÷10Vdc or other voltage range, or specific sensors from other manufacturers
M2CH.RM2CHRLabel: Red · Version for: 0÷20mA or 4÷20mA, or specific sensors from other manufacturers
M2CH.WM2CHWLabel: White · Version for: 0÷2Vdc, Pt100 or mV sensors, frequencies, pulses, or specific sensors from other manufacturers
M2CH.YM2CHYLabel: Yellow · Version for: Sinusoidal outputs, or specific sensors from other manufacturers
NESA M2CH Sensor Interface Board

Other products

NESA Environmental Meters
Rockfall alert | 1 to 8 electromechanical sensors | SigFox / LoRa 868/915MHz radio | 5-year lithium polymer battery | -40 to +60°C | Ø 30cm | CE
DPF Sensors logo
3-way galvanic isolator for 0-4/20mA and 0/10V thermocouples. In a narrow 6.2mm case.
DPF Sensors logo
3-channel encoder isolator-amplifier-doubler-adapter. Up to 1 MHz. (adapts differential signals to single-ended signals)
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Output 0…10 V, 0…20 mA or 4…20 mA | Power supply 24 VDC ± 20 % | Linearity typ. 0.01 %FS | 20 ppm/K typ. | Reference 10 VDC for sensor | DIN rail 35 mm | Galvanic isolation (MUP-160)
DPF Sensors logo
Rotation and sub-speed control relay to detect absence of movement, slippage, belt breakage and jams in industrial machinery.
NESA Environmental Meters
Pt100 + 0÷1Vdc, 4÷20mA, RS485 | -40 ÷ +80 °C / 0 ÷ 100 %Rh | Pt100 1/3DIN + Capacitive | Ø 26 x 220 mm | 10÷28Vdc | Weight < 100g
NESA Environmental Meters
Pt100, 0–1Vdc, 4–20mA, RS485 | -40–+60 °C / 0–100% | Pt100 1/3DIN + Capacitive | Ø 162 x 220 mm | 10–28Vdc | Natural or forced ventilation
DPF Sensors logo
Divisor – pulse counter by an integer (1.. 999).
DPF Sensors logo
Isolator for passive pickups. Passive output: 4/20 mA, input: 4/20 mA (for passive pickup) * 4 channels *
Shopping Basket