Signal conditioner for potentiometers MUP-110 / 160
- Manufacturer: Novotechnik
- Category: Signal converters, INSTRUMENTATION, Resistance and Potentiometers
Novotechnik MUP-110/160 signal conditioner. Interface for potentiometers with adjustable zero and range.
Signal conditioner for potentiometric sensors, with 10 VDC reference and input > 10 MΩ. Standard output 0…10 V, 0…20 mA or 4…20 mA. Typical linearity 0.01 %FS, typical temperature coefficient 20 ppm/K. Power supply 24 VDC ± 20%. Polyamide housing, 12.6 mm wide, for DIN rail mounting according to EN 60715. The MUP-160 features galvanic isolation (DC/DC transformer).
Key points
- Reference for the sensor: 10 VDC
- Galvanic isolation in the MUP-160 (DC/DC transformer)
- Standardized output signals: 0…10 V, 0…20 mA, 4…20 mA
- Typical linearity 0.01 %FS
- Typical temperature drift 20ppm/K
- For DIN rail EN 60715
- 12.6 mm wide housing
Technical Frequently Asked Questions
What sensors and signals can be connected to the MUP-110/160 signal conditioner?
Accepts input resistance: > 10 MΩ; internal reference voltage for the sensor: 10 VDC, short circuit proof.
How do I order the MUP-110/160 signal conditioner?
For example, MUP-110-0 (Art. 400054010) is the version with a non-galvanic-isolated conditioner with a 0…20 mA output. All order references with their corresponding Art. are listed in the reference table on this page.
Under what conditions does the MUP-110/160 signal conditioner operate?
Operating temperature: +5…+70 °C. Protection: IP50 / IP00 (terminals).
Properties
| Feature | Specification |
|---|---|
| Entrance | |
| Input resistance | > 10 MΩ |
| Internal reference voltage for the sensor | 10 VDC, short circuit proof |
| Sensor connection resistance | ≥ 700 Ω |
| Exit | |
| Exit signals | 0…10 V, 0…20 mA or 4…20 mA |
| Load at the current output | ≤ 500 Ω |
| Load current at the voltage output | max. 2 mA |
| Galvanic isolation | MUP-160 with insulation; MUP-110 without insulation |
| Precision | |
| Linearity | typ. 0.01 %FS, max. 0.05 %FS |
| Temperature coefficient* | typ. 20 ppm/K |
| Functions | |
| Zero point adjustment | -30…+20% |
| Gain adjustment | 0.65…2 times |
| Adjustment type | Spindle trimmers, independent of each other |
| Food and environment | |
| Working voltage | 24 VDC ± 20% |
| Reverse polarity protection | Integrated |
| No-load current consumption | max. 70 mA |
| Protection | IP50 / IP00 (terminals) |
| Working temperature | +5…+70 °C |
| EMC | EN 61326-1, EN 61326-2-3 |
| Mechanical data | |
| Dimensions | 107 x 99 x 12.6 mm |
| Bornes | Connection terminals, up to 2.5 mm² |
| Rail mounting | 35 mm (DIN EN 60715) |
| Weight | approx. 110 g |
| Housing | Polyamide |
| Accordance | |
| EU: Electromagnetic compatibility | Directive 2014/30/EU: EN 61326-1:2013, EN 61326-2-3:2013 |
| EU: RoHS | Directives 2011/65/EU and 2015/863/EU: EN IEC 63000:2018 |
| United Kingdom: Electromagnetic compatibility | SI 2016/1091: EN 61326-1:2013, EN 61326-2-3:2013 |
| United Kingdom: RoHS | SI 2012/3032 and SI 2020/1647: EN IEC 63000:2018 |
| Reference | Configuration |
|---|---|
| MUP-110-0MUP1100 | Art. 400054010 |
| MUP-110-1MUP1101 | Art. 400054011 |
| MUP-110-4MUP1104 | Art. 400054014 |
| MUP-160-0MUP1600 | Art. 400054060 |
| MUP-160-1MUP1601 | Art. 400054061 |
| MUP-160-4MUP1604 | Art. 400054064 |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications