VV1/VV1R First Class Cup Anemometer

Budget-friendly price Request a quote
Frequency, 0÷2Vdc, 4÷20mA, RS485 | 0.28 ÷ 50 m/s | First class (First Class) IEC 61400-12-1 | R 125 mm · 300 mm | 10 ÷ 28Vdc | IP68 connector

El NESA VV1 es un anemómetro de cazoletas de primera clase (First Class), fabricado según la norma IEC 61400-12 para la monitorización eólica y certificado MeasNet. Clasificación IEC 61400-12-1 y EN 15518-3:2011, conforme a WMO. Hecho en metal (aluminio anodizado y acero inoxidable), con rotor de 3 cazoletas sobre rodamientos de alta velocidad y larga duración (MIL-L-6085 C).

Range 0.28 ÷ 50 m/s (up to 80-100 m/s with frequency output only), linearity r > 0.99998 and start-up threshold < 0.3 m/s. Frequency, 0÷2Vdc, 4÷20mA or RS485/Modbus outputs, IP68 quick connection and heated version VV1R (5W @ 12Vdc).

Key points

  • Clasificación de primera clase (First Class) según IEC 61400-12-1 (Clase A: 1,96 · Clase B: 3,05 · Clase S: 2,42)
  • Linearity r > 0.99998 with a standard error of 0.02 m/s
  • Range from 0.28 to 50 m/s (up to 80-100 m/s with frequency output only)
  • MeasNet and ISO17025 calibrations
  • Heated version VV1R (5W @ 12Vdc): -40 ÷ +70 °C
  • Outputs: frequency (N), 0÷2Vdc (A), 4÷20mA (B) or RS485/Modbus (C)

Technical Frequently Asked Questions

What measurement outputs does the VV1 anemometer offer?

VV1-N: frequency 0÷150Hz (50 Ω) or 0÷300Hz. VV1-A: 0÷2Vdc = 0÷50 m/s. VV1-B: 4÷20mA = 0÷50 m/s, not self-powered. VV1-C: RS485/Modbus (9600 baud, N, 8, 1; function 0x03; standard ID 009).

What calibrations does it have?

It comes with a calibration report. NESA indicates MeasNet and ISO17025 calibrations.

What is the difference between VV1 and VV1R?

The VV1R has a low-consumption heater (5W @ 12Vdc) with a temperature control system and operates from -40 to +70 °C; the VV1, from -10 to +70 °C. Both can withstand gusts of 0 to 100 m/s.

Properties

FeatureSpecification
Wind speed measurement
Measured magnitudeWind speed
Speed range0.28 ÷ 50 m/s (up to 80-100 m/s, frequency output only)
Resolution0.05 m/s wind travel
Average accuracy< 0.1 m/s (0.4 ÷ 30 m/s); 30m/s)
Linearityr > 0.99998 (standard error 0.02 m/s; (m/s) = (Hz x 0.30) + 0.3)
Start-up threshold< 0.3 m/s
Stopping threshold0.1 m/s
IEC 61400-12-1 ClassificationPrimera clase: Clase A 1,96 · Clase B 3,05 · Clase S 2,42
StandardsIEC 61400-12-1, WMO and EN 15518-3:2011; EC
Output signals and interface
Output frequency (N)0÷150Hz (50 Ω at 20 mA max.) or 0÷300Hz
Output voltage (A)0÷2Vdc
Current output (B)4÷20mA
Serial digital output (C)RS485 / Modbus
ConnectorIP68 Quick Connect
Power supply and mechanical characteristics
Feeding10 ÷ 28Vdc (10 ÷ 16Vdc for N version)
Consumption< 0.1 W (5 W @ 12Vdc heated version VV1R)
Operating conditions-10 ÷ +70 °C (-40 ÷ +70 °C heated version VV1R); gusts 0 ÷ 100 m/s
Dimensions300 mm; R 125 mm (see drawing)
Weight< 390 g
MaterialsAnodized aluminum and stainless steel
ReferenceConfiguration
VV1-AVV1AModel: VV1 · Heating: Standard · Output signal: 0÷2Vdc
VV1-BVV1BModel: VV1 · Heating: Standard · Output signal: 4÷20mA
VV1-CVV1CModel: VV1 · Heating: Standard · Output signal: RS485/Modbus (Standard ID 009)
VV1-NVV1NModel: VV1 · Heating: Standard · Output Signal: Frequency 0÷150Hz or 0÷300Hz
VV1R-AVV1RAModel: VV1R · Heating: Heated (Pw<5W) · Output signal: 0÷2Vdc
VV1R-BVV1RBModel: VV1R · Heating: Heated (Pw<5W) · Output signal: 4÷20mA
VV1R-CVV1RCModel: VV1R · Heating: Heated (Pw<5W) · Output signal: RS485/Modbus (Standard ID 009)
VV1R-NVV1RNModel: VV1R · Heating: Heated (Pw<5W) · Output signal: Frequency 0÷150Hz or 0÷300Hz
NESA First Class VV1 Cup Anemometer
Dimensions of the NESA First Class VV1 cup anemometer

Other products

NESA Environmental Meters
4-20mA | 0-5 m/s · -20-80 °C | Omnidirectional hot wire | 120 x 80 mm control unit | 12Vdc | IP65
NESA Environmental Meters
0 ÷ 359° | Resolution 0.1° | ± 1° | 335 mm | Precision potentiometer | 0÷2Vdc, 4÷20mA, RS485 / Modbus or 10Kohm
NESA Environmental Meters
0÷70 m/s · 0÷360° | Triaxial UVW | ModBus RS485 or analog outputs | 12 ÷ 30 Vdc | 537 x 214mm | 1650g
NESA Environmental Meters
2 x 4÷20mA | 0 ÷ 50 m/s · 0 ÷ 360° | 4 ultrasonic cells | 162 x 320mm | 10÷30Vdc | IP65
NESA Environmental Meters
0-2Vdc, 4-20mA, RS485/Modbus | 0-360° | 12-bit magnetic encoder | L = 300 mm · 335 mm | 10-28Vdc | IP68 connector | Heated option (5W @ 12Vdc)
NESA Environmental Meters
2 x 4÷20mA, RS485/Modbus | 0 ÷ 90 m/s · 0 ÷ 360° | 4 ultrasonic cells | 162 x 320mm | 10÷30Vdc | IP65
DPF Sensors logo
Anemometer with pulse output, proportional to wind speed, industrial use
DPF Sensors logo
Anemometer with direct alarm output (adjustable) via relay contact. Also available with 4 to 20 mA output.
DPF Sensors logo
Wind direction sensor for industrial use, with 4-20 mA output signal
Shopping Basket