Explosion-Proof Single-Turn Absolute Encoder A/80EXS
- Manufacturer: ELCIS Encoder
- Category: Encoder, Absolute Encoder, ATEX Absolute Encoder, SENSORS
The ELCIS 80EXS (A/80EXS) is a 7-12 bit explosion-proof, single-turn absolute encoder with an 80 mm diameter housing and servo-type flange mounting. Certified by ISSeP according to CENELEC and ATEX standards, it is suitable for environments with explosive atmospheres (except firedamp), and is marked II 2 G Ex d IIC T6 Gb and D Ex tb IIIC T85°C Db IP6X.
Resolution up to 4096 steps per revolution (12 bits) in Gray, Excess, or custom code. Versions: Parallel Gray or Excess (GP, EP), serial Gray or Excess (GS, ES, RS422 transmission), and analog current (A) or voltage (V) versions, the latter two only with 15 V or 18–28 V power supply and 4096 resolution. Electronics: NPN open collector, NPN open collector + PTC, NPN open emitter + PTC, and push-pull in parallel version; serial SSI; analog 4–20 mA and 0–10 V.
Aluminum base and cover, stainless steel shaft Ø10 h7, and 1300 g weight. Connection via 1 m IP66 cable (CV1, CV7) or 26c IP65 cable end connector (VM5, TM5, only outside potentially explosive atmospheres). Options: sealed bearings (Z), stainless steel housing (N), tropicalization (G), and custom options (X). Special safe operating conditions (symbol X): cable suitable for a minimum temperature of 100 °C permanently connected to the device, with a suitable free-end connection, and mounting screws of at least grade 8.8.
- Marked II 2 G Ex d IIC T6 Gb and D Ex tb IIIC T85°C Db IP6X, ISSeP07ATEX018X certificate.
- One-way trip 7 to 12 bit, until 4096 steps per lap.
- Exit parallel, SSI series (RS422) either analog (the latter only with 15V or 18-28V and 4096 resolution).
- Stainless steel shaft Ø10 h7, max. radial/axial load. 10 kg.
- IP65 standard on the axle side e IP66 with sealed bearings (option Z).
Technical Frequently Asked Questions
What ATEX marking and certification does the 80EXS single-turn encoder have?
It has markings II 2 G Ex d IIC T6 Gb and D Ex tb IIIC T85°C Db IP6X, certified by ISSeP (ISSeP07ATEX018X) and notified by CESI (CESI02ATEX138Q), according to EN60079-0, EN60079-1 and EN60079-31, with ATEX directive 94/9/EC. Special conditions (symbol X): cable suitable for 100 °C minimum and mounting screws of at least 8.8.
What electronic outputs and interfaces does the 80EXS single-turn encoder have?
Parallel versions (GP, EP) with NPN open collector 10 mA, NPN open collector 10 mA + PTC, NPN open emitter 10 mA + PTC or push-pull 10 mA + PTC electronics; SSI series (GS, ES) with RS422 transmission and 125 kHz clock, only with Gray or Excess code; and analog in current (A) or voltage (V), only with 15 V or 18÷28 V power supply and 4096 resolution.
What connections and IP rating does it support?
1 m IP66 cable (CV1, and CV7 only in parallel GP, EP version) or 26c IP65 cable end connector (VM5) and 26c sealed IP65 (TM5), these two only outside of potentially explosive atmospheres. Shaft side: IP65 standard and IP66 with sealed bearings (Z). Option N: stainless steel housing.
Properties
| Feature | Specification |
|---|---|
| Mechanics | |
| Base and lid | Aluminum (customizable upon request) |
| Weight | 1300 g |
| Axis | Ø10 h7 stainless steel |
| max radial/axial load. | 10 kg |
| Electric | |
| Exit-side protection | According to connection: IP66 cable, connector at IP65 end of cable |
| Max resolution. | 4096 steps/turn (12 bit); single turn from 7 to 12 bit |
| Exit codes | Gray, Excess, Custom |
| Max frequency. | 50 kHz (SSI clock: 125 kHz) |
| Vcc Power Supply | 5 V ±5 %, 15 V ±5 %, 8÷24 V, 18÷28 V |
| Max. consumption. | 180 mA |
| Protection and environment | |
| axle-side protection | IP65 standard · IP66 with sealed bearings (Z) (IP rating according to CEI EN 60529, EN 60529, IEC 529) |
| max. continuous RPM | 6000 standard · 3000 with sealed bearings (Z) |
| Impact/vibration resistance | 50 G (11 ms) · 12 G (10 ÷ 2000 Hz) |
| Ambient temp. (T6) / storage | -20 … +40 °C / -30 … +85 °C |
| Other features | |
| Interfaces | Parallel (GP, EP), SSI series (GS, ES; only with Gray or Excess code), analog in current (A) and in voltage (V) (only with 15 V or 18÷28 V power supply and 4096 resolution) |
| Reference | Configuration |
|---|---|
| A/80EXS-10-5-GP-1-CV7-RA80EXS105GP1CV7R | 10 steps/turn · 5 V ±5 % · gray · NPN open collector 10 mA; parallel version only (GP, EP) · 1 m cable, IP66 (parallel version GP, EP only) · radial output |
| A/80EXS-12-5-GP-1-CV7-RA80EXS125GP1CV7R | 12 steps/turn · 5 V ±5 % · gray · NPN open collector 10 mA; parallel version only (GP, EP) · 1 m cable, IP66 (parallel version GP, EP only) · radial output |
| Other combinations of resolution, power supply, electronics and connection are available upon request: please contact us and we will confirm the exact reference. | |