IEPE Monitran MTN/1100 industrial accelerometer
- Manufacturer: Monitran
- Category: Accelerometers and Vibration Sensors, Amplified, SENSORS
The Monitran MTN/1100 series comprises general-purpose, constant-current, isolated AC-output industrial accelerometers with a standard sensitivity of 100 mV/g ±10% nominal at 80 Hz, a frequency response of 2 Hz to 10 kHz ±5%, and a dynamic range of ±80 g. The datasheets cite applications such as data acquisition, general and heavy industry, paper machinery, pumps and fans, air handling units, machine tools, and, in the submersible versions, submersible pumps and roller monitoring.
All versions are made of stainless steel. The input is either top-mounted (MTN/1100, 1100C, 1100T, 1100TC, 1100W, and 1100TW) or side-mounted (1100S, 1100SC, 1100STC, and 1100SW), with a 2-pin C5015 connector, a 3-pin 62GB connector, or an integral ETFE cable with stainless steel braiding (IP67). Submersible versions (IP68, 100 m max., 10 bar) use an integral heavy-duty polyurethane cable. The T, TC, STC, and TW versions also include a 10 mV/°C temperature output. Guemisa is an official distributor of Monitran in Spain.
Key points
- Standard sensitivity of 100 mV/g ±10% nominal at 80 Hz; other sensitivities depending on the version: 10, 30, 50, 500 and 1000 mV/g (1100, 1100T, 1100TC and 1100TW), in addition to 20 and 25 mV/g (1100C), and 10, 25, 30 and 50 mV/g (1100S, 1100SC, 1100STC and 1100SW)
- Frequency response of 2 Hz to 10 kHz ±5% (-3 dB at 0.8 Hz), mounted base resonance of 18 kHz (nominal) and electrical noise of 0.1 mg max. (0.3 mg max. in temperature-controlled versions)
- IP68 submersible versions (1100SW, 1100W and 1100TW; 100 m max., 10 bar) and versions with a temperature output of 10 mV/°C in the range of 2 to 100 °C (1100T, 1100TC, 1100STC and 1100TW)
Technical Frequently Asked Questions
What are the differences between the versions of the Monitran MTN/1100?
They are distinguished by their input (top or side), connection (2-pin C5015 connector, 3-pin 62GB connector, or integral ETFE or polyurethane cable), sealing (IP67 or IP68 submersible), and temperature output (T, TC, STC, and TW versions). All share a 100 mV/g ±10% response rate at 80 Hz, 2 Hz at 10 kHz ±5% response rate, and a stainless steel housing.
Which versions of the MTN/1100 can be submerged?
The IP68 models: MTN/1100SW (side), MTN/1100W (top, ±50 g) and MTN/1100TW (top, with temperature). They withstand a maximum immersion of 100 m (10 bar), have an integral heavy-duty polyurethane cable, and operate from -55 to 90 °C (1100SW) or from -25 to 90 °C (1100W and 1100TW).
Which versions of the MTN/1100 also provide temperature readings?
MTN/1100T, 1100TC, 1100STC and 1100TW: AC(g) and temperature isolated outputs, with 10 mV/°C in the range of 2 to 100 °C and electrical noise of 0.3 mg max. (0.1 mg max. in the other versions).
Properties
| Feature | Specification |
|---|---|
| Measure and signal | |
| Measured magnitude | Acceleration (vibration) |
| Exit | Isolated AC, constant current; in 1100T, 1100TC, 1100STC and 1100TW, isolated AC(g) outputs and temperature |
| Standard sensitivity | 100 mV/g ±10% nominal at 80 Hz |
| Optional Sensitivities (xx) | 10, 30, 50, 500 and 1000 mV/g (1100, 1100T, 1100TC, 1100TW); 10, 20, 25, 30, 50, 500 and 1000 mV/g (1100C); 10, 25, 30 and 50 mV/g ±10% (1100S, 1100SC, 1100STC, 1100SW) |
| Temperature output sensitivity | 10 mV/°C (range 2 to 100°C), on 1100T, 1100TC, 1100STC and 1100TW |
| Measurement ranges | ±80 g (dynamic range); ±50 g at 1100W |
| Frequency response | 2 Hz to 10 kHz ±5% (-3 dB at 0.8 Hz) |
| Mounted base resonance | 18 kHz (nominal); 18 kHz min. at 1100W |
| Cross-sectional sensitivity | Less than 5% |
| Electrical noise | 0.1 mg max; 0.3 mg max on 1100T, 1100TC, 1100STC and 1100TW |
| Food and environment | |
| Current range | 0.5 to 8 mA |
| Polarization voltage | 12 V DC (nominal) |
| System connection diagram | +18 to +30 V power supply with constant current diode (0.5 to 8.0 mA) |
| Isolation | Isolated base |
| Temperature range | -55 to 140°C (1100, 1100C, 1100S, 1100SC, 1100STC, 1100T, 1100TC); -55 to 90°C (1100SW); -25 to 90°C (1100W and 1100TW) |
| Sealed | IP67; IP68 in 1100SW, 1100W and 1100TW |
| Diving depth | 100m max (10 bar), in 1100SW, 1100W and 1100TW |
| Mechanics and connection | |
| Housing material | Stainless steel |
| Entrance | Top (1100, 1100C, 1100T, 1100TC, 1100W, 1100TW) or side (1100S, 1100SC, 1100STC, 1100SW) |
| Connection | 2-pin C5015 connector (1100, 1100S); 3-pin 62GB connector (1100T); integral ETFE cable with stainless steel braid (1100C, 1100SC, 1100STC, 1100TC); integral heavy-duty polyurethane cable (1100SW, 1100W, 1100TW) |
| Mating connector | MTN/MH002 (1100 and 1100S); MTN/MH008 (1100T) |
| Standard cable length | 5m (1100C, 1100SC, 1100STC, 1100TC) |
| Maximum cable length | 1000m (1100, 1100S, 1100T, 1100TW); 100m (1100C, 1100SC, 1100STC, 1100SW, 1100W, 1100TC) |
| Mounting bolt included | ¼"-28 UNF, M6 or M8 (1100S, 1100SC, 1100STC, 1100SW) |
| Tightening torque | 8 Nm |
| Weight | 110g (nominal) in 1100, 1100C, 1100T and 1100TC; 170g (nominal) on 1100S, 1100SC, 1100STC and 1100SW; 120 g (nominal) in 1100W and 1100TW |
| Dimensions (MTN/1100, according to drawing) | 51.0 mm high, Ø22.0 mm, 25 mm across faces |
| Reference | Configuration |
|---|---|
| MTN/1100-xx MTN1100XX | Variant: MTN/1100 · Mounting: ¼"-28 UNF female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100 Technical Data Sheet (PDF) |
| MTN/1100C-xx MTN1100CXX | Variant: MTN/1100C · Mounting: ¼" UNF female · xx = optional sensitivity in mV/g: 10, 20, 25, 30, 50, 500 or 1000 MTN/1100C technical data sheet (PDF) |
| MTN/1100CQ-xx MTN1100CQXX | Variant: MTN/1100C · Mounting: Q/F female · xx = optional sensitivity in mV/g: 10, 20, 25, 30, 50, 500 or 1000 MTN/1100C technical data sheet (PDF) |
| MTN/1100Q-xx MTN1100QXX | Variant: MTN/1100 · Mounting: Q/F female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100 Technical Data Sheet (PDF) |
| MTN/1100S-xx MTN1100SXX | Variant: MTN/1100S · Mounting: ¼"-28 UNF x 33 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100S technical data sheet (PDF) |
| MTN/1100SC-xx MTN1100SCXX | Variant: MTN/1100SC · Mounting: ¼"-28 UNF x 33 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SC technical sheet (PDF) |
| MTN/1100SCM6-xx MTN1100SCM6XX | Variant: MTN/1100SC · Mounting: M6 x 35 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SC technical sheet (PDF) |
| MTN/1100SCM8-xx MTN1100SCM8XX | Variant: MTN/1100SC · Mounting: M8 x 28 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SC technical sheet (PDF) |
| MTN/1100SM6-xx MTN1100SM6XX | Variant: MTN/1100S · Mounting: M6 x 35 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100S technical data sheet (PDF) |
| MTN/1100SM8-xx MTN1100SM8XX | Variant: MTN/1100S · Mounting: M8 x 28 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100S technical data sheet (PDF) |
| MTN/1100STC-xx MTN1100STCXX | Variant: MTN/1100STC · Mounting: ¼"-28 UNF x 33 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100STC data sheet (PDF) |
| MTN/1100STCM6-xx MTN1100STCM6XX | Variant: MTN/1100STC · Mounting: M6 x 35 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100STC data sheet (PDF) |
| MTN/1100STCM8-xx MTN1100STCM8XX | Variant: MTN/1100STC · Mounting: M8 x 28 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100STC data sheet (PDF) |
| MTN/1100SW-xx MTN1100SWXX | Variant: MTN/1100SW · Mounting: ¼"-28 UNF x 33 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SW data sheet (PDF) |
| MTN/1100SWM6-xx MTN1100SWM6XX | Variant: MTN/1100SW · Mounting: M6 x 35 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SW data sheet (PDF) |
| MTN/1100SWM8-xx MTN1100SWM8XX | Variant: MTN/1100SW · Mounting: M8 x 28 mm bolt · xx = optional sensitivity in mV/g: 10, 25, 30 or 50 (±10%) MTN/1100SW data sheet (PDF) |
| MTN/1100T-xx MTN1100TXX | Variant: MTN/1100T · Mounting: ¼"-28 UNF female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100T technical data sheet (PDF) |
| MTN/1100TC-xx MTN1100TCXX | Variant: MTN/1100TC · Mounting: ¼"-28 UNF female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100TC technical sheet (PDF) |
| MTN/1100TCQ-xx MTN1100TCQXX | Variant: MTN/1100TC · Mounting: Q/F female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100TC technical sheet (PDF) |
| MTN/1100TQ-xx MTN1100TQXX | Variant: MTN/1100T · Mounting: Female Q/F · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100T technical data sheet (PDF) |
| MTN/1100TW-xx MTN1100TWXX | Variant: MTN/1100TW · Mounting: ¼"-28 UNF female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100TW data sheet (PDF) |
| MTN/1100TWQ-xx MTN1100TWQXX | Variant: MTN/1100TW · Mounting: Q/F female · xx = optional sensitivity in mV/g: 10, 30, 50, 500 or 1000 MTN/1100TW data sheet (PDF) |
| MTN/1100W-xx MTN1100WXX | Variant: MTN/1100W · Mounting: ¼"-28 UNF female · xx: the sheet does not indicate the values MTN/1100W technical data sheet (PDF) |
| MTN/1100WQ-xx MTN1100WQXX | Variant: MTN/1100W · Mounting: Q/F female · xx: the sheet does not indicate the values MTN/1100W technical data sheet (PDF) |


Related documentation, cases, and guides
Other products