RFD-4000 Two-Piece Non-Contact Angle Sensor
- Manufacturer: Novotechnik
- Category: Displacement, Encoder, Absolute Encoder, Single-turn Absolute Encoder, Absolute Magnetic Encoder, Angular displacement sensor, SENSORS
Novotechnik RFD-4000 Non-Contact Angle Sensor. Non-contact Hall angle sensor, up to 360° and 7 mm high.
Two-piece, non-contact Hall effect angle sensor: sensor and magnetic position marker fixed to the shaft, without shaft or bearing. Electrical range up to 360°, linearity ±0.5%, 12-bit resolution. Ratiometric analog output 0.25 … 4.75 V. 7 mm height. IP67, IP68, and IP69 protection. Wired connection.
Key points
- Contactless, axleless
- Measurement through non-ferromagnetic material
- Electrical range up to 360°, linearity ±0.5%
- Lateral displacement of the magnet up to ±3 mm
- IP67, IP68, IP69 protection; single and multi-channel versions
- Unlimited mechanical life; up to 12-bit resolution; 7 mm height
Technical Frequently Asked Questions
What can be connected to the RFD-4000 contactless angle sensor?
It can be connected to Novotechnik rotary sensor positioners (magnets) and a multifunction meter with digital display for direct connection of potentiometric and standardized MAP-4000 signals.
How do I order the RFD-4000 contactless angle sensor?
The order code has 7 fields: mechanical version, channels, range, Ub, signal, feature, and connection. For example, RFD-4021-636-211-401 is the version with a standard design, 1 channel, range of 0° to 360°, Ub = 5 VDC, output 5…95% ratiometric increasing clockwise, and 3 wires of 0.5 m. All the options for each field are available in the order code configurator on this page.
Under what conditions does the RFD-4000 contactless angle sensor operate?
Operating temperature: -40 … +125 °C. Protection: IP67 / IP68 / IP69.
Properties
| Feature | Specification |
|---|---|
| Measurement and exit signal | |
| Exit sign | Ratiometric at supply voltage Ub: 5 … 95 % (0.25 … 4.75 V) or 10 … 90 % (0.5 … 4.5 V) |
| Burden | ≥ 10 kΩ |
| Number of channels | 1 / 2 |
| Diagnosis | Activated (in error, the signal is outside the plausible range) |
| Update frequency | typical 2.5 kHz |
| Measuring range | 0 … 30° to 0 … 360°, in 10° steps |
| Independent linearity | ≤ ±0.5% FS (with 10 kΩ pull-down resistor) |
| Resolution | 12 bits |
| Repeatability | typical ≤ ±0.1° |
| Temperature error, range 30 … 170° | typ. ±0.875 % FS |
| Temperature error, range ≥ 180° | typ. ±0.6% FS |
| Feeding and protection | |
| Supply voltage Ub | 5 VDC (4.5 … 5.5 VDC) |
| No-load current consumption | typical 13 mA per channel (typical 8 mA on request) |
| Reverse polarity protection | Yes (feed lines) |
| Short circuit protection | Yes (all outputs connected to GND and the supply voltage) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Environmental conditions | |
| Working temperature | -40 … +125 °C |
| Vibration IEC 60068-2-6 | 20 g, 5 … 2000 Hz, Amax = 0.75 mm |
| IEC 60068-2-27 Shock | 50 g, 6 ms |
| DIN EN 60529 protection | IP67 / IP68 / IP69 |
| Maximum working speed and life | Mechanically unlimited |
| MTTF (IEC 60050) | 9926 years (1 channel), 4441 years (partially redundant, per channel) or 4512 years (fully redundant, per channel) |
| Electromagnetic compatibility | |
| ISO 10605 ESD (handling/component) | 8 kV / 15 kV |
| ISO 11452-2 Radiated HF fields | 200 V/m |
| ISO 11452-5 Radiated HF fields, stripline | 200 V/m |
| CISPR 25 Radiated emission | Level 5 |
| EN 61000-4-4 Fast transients (burst) | 1 kV |
| EN 61000-4-6 Conducted disturbances (HF fields) | 10 V ef. |
| EN 61000-4-8 Magnetic fields | 30 A/m |
| Mechanical data | |
| Housing | Temperature-resistant PBT-GF plastic with brass inserts |
| Fixation | 2 M4x14 socket head cap screws (included in the supply) |
| Tightening torque of the fastener | max. 150 Ncm |
| Mechanical tour | Continuous |
| Weight | approx. 10 g |
| Electrical connection | 0.5 mm² (AWG 20) PVC wires |
| Process accessories | |
| Reference | Description |
| MAP-4000 | Multifunction meter with digital display for direct connection of potentiometric and standardized signals |
| Option | Meaning |
|---|---|
| Example: RFD-4021-636-211-401 = standard design, 1 channel, range 0° to 360°, Ub = 5 VDC, output 5 … 95 % ratiometric increasing clockwise and 3 wires of 0.5 m. | |
| 1 · Mechanical version | |
| 4021 | Standard design |
| 2. Number of channels | |
| 6 | 1 channel (1x Ub / 1x output) |
| 7 | Partially redundant (1x Ub / 2x output) |
| 8 | Fully redundant (2x Ub / 2x output) |
| 3 · Measurement range | |
| 03 | 0° … 30° min. |
| 06, 12, 18, 24, 36 | 0° … 60°, 120°, 180°, 240°, 360° |
| 36 | 0° … 360° max. |
| 4 · Supply voltage Ub | |
| 2 | Ub = 5 VDC |
| 5 · Output signal | |
| 1 | 5 … 95 % ratiometric to Ub (0.25 … 4.75 VDC) |
| 2 | 10 … 90 % ratiometric to Ub (0.5 … 4.5 VDC) |
| 6 · Output characteristic | |
| 1 | Clockwise increasing |
| 2 | Crescent in a counterclockwise direction |
| 3 | Cross-outputs, channel 1 increasing clockwise (partially redundant) |
| 4 | Cross-outputs, channel 1 increasing clockwise (fully redundant) |
| 7 · Electrical connection | |
| 401 | Threads, 3x L = 0.5 m (1 channel) |
| 411 | Threads, 4x L = 0.5 m (partially redundant) |
| 421 | Threads, 6x L = 0.5 m (fully redundant) |
| The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference. | |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications