RFC-4800 Analog Non-Contact Angle Sensor

Budget-friendly price Request a quote
Voltage, current, or ratiometric output | Ø 48 mm | 12-bit resolution | Shaftless: magnetic position marker | 5 VDC, 12/24 VDC, or 24 VDC | IP67 / IP68 / IP69 | 1 or 2 channels

Novotechnik RFC-4800 analog angle sensor. Non-contact Hall angle sensor, up to 360°.

Key points

  • Contactless Hall technology, electrical range up to 360°
  • Unlimited mechanical life
  • Two-piece design, mechanically decoupled, without shaft or bearing; measured through non-ferromagnetic material
  • IP67, IP68, IP69 protection
  • Single and multi-channel mobile versions: safety according to DIN EN ISO 13849; EMC according to ISO pulses, ISO 11452 and ECE standard

Technical Frequently Asked Questions

What can be connected to the RFC-4800 analog angle sensor?

It can be connected to Novotechnik M12 connectors and cables and Novotechnik rotary sensor positioners (magnets).

How do I order the RFC-4800 analog angle sensor?

The order code has 7 fields: mechanical version, channels, range, Ub, signal, feature, and connection. For example, RFC-4851-636-111-202 is the version with an elongated hole and diagnostics, 1 channel, 0° to 360°, Ub = 24 VDC, 0.1 … 10 V increasing clockwise, and a 1 m shielded 4-pole cable. All the options for each field are available in the order code configurator on this page.

Under what conditions does the RFC-4800 analog angle sensor operate?

Protection: IP67 / IP68 / IP69; IP67 (M12 connector).

Properties

FeatureSpecification
Applications, compliance and functional safety
Industrial applicationsManufacturing engineering (textile, packaging, sheet metal and wire machinery), automation technology and medical technology
AccordanceCE, UKCA (mobile versions also E1); WEEE marking
Mobile appsMobile work machines (industrial trolleys, construction machinery, agricultural and forestry machinery) and marine applications
Applications, compliance and functional safety
Functional security, mobile versionsAccording to ISO 13849 after customer validation; security data (DCavg…) on request
Measurement data
Measuring range0 … 30° to 0 … 360°, in 10° steps
DiagnosisActivated (in error, the signal is outside the plausible range)
Update frequencytypical 3.4 kHz
Independent linearity≤ ±0.5 % FS
Resolution12 bits
Repeatabilitytypical ≤ ±0.1°
Hysteresistypical < ±0.1° (360° range: typical < 0.25°; smaller, on request)
Electrical data and environmental conditions
No-load consumption and protectionstypical 12 mA per channel; protected against reverse polarity and short circuit
Insulation resistance (500 VDC)≥ 10 MΩ
Vibration IEC 60068-2-620 g, 5 … 2000 Hz, Amax = 0.75 mm
IEC 60068-2-27 Shock50 g, 6 ms
DIN EN 60529 protectionIP67 / IP68 / IP69; IP67 (M12 connector)
Maximum working speed and lifeMechanically unlimited
Electromagnetic compatibility
IndustrialWorth
EN 61000-4-2 ESD (contact/air)4 kV, 8 kV
EN 61000-4-3 Electromagnetic fields (RFI)10 V/m
EN 61000-4-4 Fast transients (burst)1 kV
EN 61000-4-6 Conducted disturbances (HF fields)10 V ef.
EN 55016-2-3 Radiated disturbancesIndustrial and residential
Electromagnetic compatibility
MobileWorth
ISO 10605 ESD (handling/component)8 kV / 15 kV
ISO 11452-2 Radiated HF fields100 V/m
ISO 11452-5 Radiated HF fields, stripline200 V/m
CISPR 25 Radiated emissionLevel 5
ISO 7637-2 Transient emissions (voltage and current)Level 3
ISO 7637-2 Power supply impulses (voltage and current)Level 4
ISO 7637-3 Output pulses (voltage and current)Level 4
EN 13309 Construction machinery; requirements E1According to ECE-R10
ISO 13766-1/-2 Construction machineryMultichannel (ratiometric: on request)
OptionMeaning
Example: RFC-4851-636-111-202 = elongated hole with diagnostics, 1 channel, 0° to 360°, Ub = 24 VDC, 0.1 … 10 V increasing clockwise, 1 m shielded 4-pole cable.
1 · Mechanical version
4851Elongated hole, with position adjustment
4852Round hole
4853Elongated hole, no diagnostic function
4854Round hole, no diagnostic function
2. Number of channels
61 channel (1x Ub / 1x output)
7Partially redundant (1x Ub / 2x output)
8Fully redundant (2x Ub / 2x output), mobile versions only
3 · Measurement range
030° … 30° min.
06, 12, 18, 24, 360° … 60°, 120°, 180°, 240°, 360°
360° … 360° max. (other angles available upon request)
4 · Supply voltage Ub
124 VDC (industrial)
25 VDC (ratiometric)
312/24 VDC (mobile)
5 · Output signal (24 V)
10.1 … 10 V
24 … 20 mA
5 · Output signal (12/24 V)
40.5 … 4.5 VDC
50.25 … 4.75 VDC
24 … 20 mA
5 · Output signal (ratiometric)
15 … 95 % ratiometric to Ub (0.25 … 4.75 VDC)
210 … 90 % ratiometric to Ub (0.5 … 4.5 VDC)
6 · Output characteristic
1Clockwise increasing
2Crescent in a counterclockwise direction
3Cross-outputs, channel 1 increasing clockwise (partially redundant)
4Cross-outputs, channel 1 increasing clockwise (fully redundant)
7 · Connection, industrial versions
2014-pole cable, shielded, L = 0.5 m
202, 206, 210, 2204-pole cable, shielded, L = 1, 3, 5 or 10 m
501M12x1 4-pin connector with shielded cable, L = 0.15 m
7 · Connection, mobile versions
2514-pole cable, unshielded, L = 0.5 m
252, 256, 260, 2704-pole cable, unshielded, L = 1, 3, 5 or 10 m
401Threads, 3x L = 0.5 m (1 channel)
411Threads, 4x L = 0.5 m (partially redundant)
421Threads, 6x L = 0.5 m (fully redundant)
551M12x1 4-pin connector with cable, unshielded, L = 0.15 m
552AMP Superseal 4-pole connector with cable, unshielded, L = 0.15 m
The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference.
Novotechnik Analog RFC-4800 Non-Contact Angle Sensor
Dimensional Plane Novotechnik Analog RFC-4800 Non-Contact Angle Sensor

Other products

DPF Sensors logo
In-place inclinometer
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø6–10 mm | Housing Ø59 mm | 1 to 25000 imp/rev | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP64 shaft (IP66 Z-seal) | Patented flare flange
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
DeviceNet (D2), programmable speed | Housing Ø58 mm, servo mounting | Shaft Ø10 h8 (Ø6 optional) | 16 bit; 30 bit at 16384 revolutions | 10–30 V DC | IP64 shaft (IP66 sealed)
ATESTEO LOGO, manufacturer of torque sensors
Inductive (Dual-Frequency) | 50 N·m – 500 N·m | 30,000 RPM | PCD flange 101.5 mm
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
SPI (TTL) | Ø 48 mm | Resolution up to 14 bits | Shaftless: magnetic position marker | 5 VDC (4.5 … 5.5 VDC) | IP67 / IP68 / IP69
NESA Environmental Meters
4÷20mA / ModBus RS485 | NO2 | 0÷20 / 0÷200 ppm | -30 ÷ 50°C | 11…30 Vdc | IP54 | 230g
Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67 | Group I (mining)
NESA Environmental Meters
4-20mA | 0-5 m/s · -20-80 °C | Omnidirectional hot wire | 120 x 80 mm control unit | 12Vdc | IP65
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Voltage, current or ratiometric output | Ø 36mm | Resolution 16 bits | Shaft Ø 6 mm, Ø 10 mm or hollow Ø 6 mm | 5 VDC or 24 VDC | IP67 / IP6K9K | 2 to 16 turns (up to 5760°)
Shopping Basket