Novotechnik TM1 analog threaded flange transducer. NOVOSTRICTIVE technology, non-contact.
Absolute linear magnetostrictive transducer with stainless steel flange welded to the rod. Stroke from 50 to 2000 mm. Working pressure up to 350 bar. Passive annular position marker. Industrial and mobile application versions.
Key points
- Working pressure up to 350 bar, peak pressure up to 450 bar
- Unlimited mechanical life
- No speed limit for the position marker
- Absolute exit
Technical Frequently Asked Questions
What can be connected to the TM1 analog threaded flange transducer?
It can be connected to Novotechnik M12 connectors and cables and Novotechnik linear sensor positioners (magnets and cursors).
How do I order the TM1 analog threaded flange transducer?
The order code has six fields: stroke (mm), mechanical version, power supply, signal, characteristic, and connection. For example, TM1-0500-306-851-104 is the version with an electrical range of 500 mm, M18x1.5 threaded flange, 24 VDC power supply, 0.25–4.75 V output, upward characteristic as seen from the flange, and a 4-pole M12x1 connector. All the options for each field are available in the order code configurator on this page.
Under what conditions does the TM1 analog threaded flange transducer operate?
Operating temperature: -40 … +105 °C. Protection: IP67.
Properties
| Feature | Specification |
|---|---|
| Description | |
| Flange | Stainless steel 1.4307 / AISI 304L |
| Flange cover | AlSiMgBi |
| Rod | Stainless steel 1.4571 / AISI 316Ti |
| Watertightness | NBR 90 SH A O-ring |
| Assembly, Industrial | Screwed in using M18x1.5 thread |
| Assembly, Mobile Applications | Screwed into the cylinder using an M18x1.5 socket for threaded plug hole according to ISO 6149 |
| Electrical connection, Industrial | M12x1 connector, A encoding |
| Electrical connection, Mobile applications | M12x1 connector, A coding / 3x 0.5 mm² (AWG 20) cable, PUR, unshielded |
| Electrical data | |
| Electrical range (L dimension) | 0 … 50 mm up to 0 … 2000 mm |
| Voltage output signal, codes 84_ and 85_ | 0.25…4.75 V and 0.5…4.5 V |
| Voltage output signal, code 81_ | 0.1 … 10 V |
| Voltage output load | ≥ 10 kΩ (pulldown) |
| Current output signal, codes 82_ and 8B_ | 4 … 20 mA |
| Current output load, with Ub 24 V | ≤ 500 Ω |
| Charging the current output, with Ub 12 V | ≤ 250 Ω |
| Sampling frequency (update) | 0.5 kHz |
| Absolute linearity | ≤ ±0.04 % FS (min. 300 µm) |
| Electrical zero point tolerance | ±1 mm |
| Resolution | ≤ 0.1 mm |
| Repeatability | ≤ ±0.1 mm |
| Hysteresis | ≤ ±0.1 mm |
| Temperature error | typ. 50 ppm/K (min. 0.01 mm/K) |
| Supply voltage Ub, outputs of 0.25 … 4.75 V and 0.5 … 4.5 V | 12/24 VDC (8 … 32 VDC) |
| Supply voltage Ub, output 0.1 … 10 V | 24 VDC (16 … 34 VDC) |
| Supply voltage Ub, output of 4 … 20 mA | 12/24 VDC (8 … 32 VDC) |
| Power supply voltage ripple | ≤ 10 % Ub |
| No-load consumption | < 1 W |
| Error signal out of measurement range, code 81_ | ≥ 12 VDC |
| Error signal out of measurement range, codes 84_ and 85_ | ≥ 5.5 VDC |
| Error signal out of measurement range, codes 82_ and 8B_ | ≥ 24 mA |
| Error signal due to GND cable breakage, codes 82_ and 8B_ | ≤ 3.5 mA |
| Overvoltage protection | 36 VDC (permanent) |
| Reverse polarity protection | Yes (-36 VDC) |
| Short circuit protection | Yes (output to GND and supply voltage up to 36 VDC) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Environmental conditions | |
| Maximum working speed | Mechanically unlimited |
| Vibration IEC 60068-2-6 | 20 g, 10 … 2000 Hz, Amax = 0.75 mm |
| IEC 60068-2-27 Shock | 100 g, 11 ms (one stroke) |
| DIN EN 60529 protection | IP67 |
| Working temperature | -40 … +105 °C |
| Working humidity | 0 … 95 % HR (non-condensing) |
| Working pressure | ≤ 350 bar |
| Pressure spikes | ≤ 450 bar |
| Bursting pressure | > 700 bar |
| Life | Mechanically unlimited |
| MTTF (IEC 60050), voltage output | 346 years |
| MTTF (IEC 60050), current output | 355 years |
| EMC, Industrial version | |
| EN 61000-4-2 ESD, discharge by contact | 4 kV |
| EN 61000-4-2 ESD, air discharge | 8 kV |
| EN 61000-4-3 Electromagnetic fields (RFI) | 10 V/m |
| EN 61000-4-4 Fast transients (burst) | 1 kV |
| EN 61000-4-6 Conducted disturbances (HF fields) | 10 V ef. |
| EN 55016-2-3 Radiated disturbances | Industrial and residential area |
| EMC, Mobile Applications version | |
| ISO 10605 ESD (handling) | 8 kV |
| ISO 10605 ESD (component) | 15 kV |
| ISO 11452-2 Radiated HF fields | 100 V/m |
| ISO 11452-4 BCI (mass current injection) | 200 mA |
| CISPR 25 Radiated emission | Level 4 |
| ISO 7637-2 Transient emissions | Level 1/2 |
| ISO 7637-2 Pulses on the feed lines (1, 2a, 2b, 3a, 3b) | Level 4 |
| ISO 7637-3 Pulses on output lines (3a, 3b) | Fast Level 2 |
| ISO 16750 Pulses on power lines, startup profile | Level 4 with 12V; Level 3 with 24V |
| ISO 16750 Pulses on power lines, Load dump A | +200 V |
| EN 13309 Construction machinery | Emission and disturbance resistance: exceeds E1 requirements |
| ISO 14982 Agricultural and forestry machinery | Emission and disturbance resistance: exceeds E1 requirements |
| Option | Meaning |
|---|---|
| Example: TM1-0500-306-851-104 = 500 mm electrical range, M18x1.5 threaded flange, 24 VDC power supply, 0.25 … 4.75 V output, rising characteristic viewed from the flange and 4-pole M12x1 connector. | |
| 1. Electrical range (mm) | |
| 0050 … 2000 | Standard, 25 mm increments; other lengths available upon request |
| 2 · Mechanical version | |
| 306 | M18x1.5 threaded flange |
| 308 | M18x1.5 threaded flange with M4x6 internal thread at the rod end (7.5 mm longer) |
| 3 · Ub Power Supply | |
| 8 | 24 VDC (16 … 34 VDC), signal 1 |
| 8 | 12/24 VDC (8 … 32 VDC), signals 4, 5, 2 and B |
| 4 · Output signal | |
| 1 | 0.1 … 10 VDC |
| 4 | 0.5 … 4.5 VDC |
| 5 | 0.25 … 4.75 VDC |
| B | 4 … 20 mA (Industrial) |
| 2 | 4 … 20 mA (Mobile applications) |
| 5 · Output characteristic | |
| 1 | Ascending view, seen from the flange |
| 2 | Downward, viewed from the flange |
| 6. Electrical connection | |
| 104 | M12x1 connector, 4 poles |
| 251 | Mobile applications: unshielded 3-wire cable, A = 1 m |
| 253 | Mobile applications: unshielded 3-wire cable, A = 3 m |
| 255 | Mobile applications: unshielded 3-wire cable, A = 5 m |
| The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference. | |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications
Other products