TA air temperature sensor

Budget-friendly price Request a quote
Pt100, 0÷2Vdc, 4÷20mA, RS485 | -40 ÷ +60 °C | Pt100 1/3DIN (±0.1°C @ 0°C) | Ø 162 x 220 mm | 10÷30Vdc | Natural or forced ventilation

The NESA TA is an air temperature sensor with a Pt100 platinum element 1/3DIN (100 Ω @ 0 °C), typical measuring range of -40 ÷ +60 °C and anti-radiation shelter compliant with WMO and EN 15518-3:2011.

The resistance variation of the Pt100 probe, according to DIN 43760 1/3DIN, is supplied directly with a 4-wire connection (TA-N / TAV-N version) or converted into a standardized signal in voltage 0–2Vdc (TA-A / TAV-A), current 4–20mA (TA-B / TAV-B), or RS485 / ModBus RTU digital bus (TA-C / TAV-C). The sensing element is housed within a set of screens with a reflective white coating that protects against direct sunlight and UV radiation, with either natural ventilation (TA code) or forced ventilation (TAV code).

Key points

  • Platinum Pt100 resistance thermometer (100 Ω @ 0 °C) according to DIN 43760 1/3DIN (±0.1 °C @ 0 °C)
  • Resolution of 0.01 °C and response time of less than 10 s
  • Anti-radiation screens with natural (TA) or forced (TAV) ventilation in accordance with WMO and EN 15518-3:2011
  • Available outputs: 4-wire Pt100 (N), 0÷2Vdc (A), 4÷20mA (B) and RS485 / ModBus (C)
  • Aluminum alloy with stainless steel screws

Technical Frequently Asked Questions

What output signals does the TA air temperature sensor deliver?

It is supplied factory pre-configured in four output versions: N (4-wire natural Pt100, 100 Ω @ 0 °C), A (0÷2Vdc voltage for -40…+60 °C), B (4÷20mA non-self-powered current for -40…+60 °C) and C (RS485 Half duplex digital interface with ASCII request xxxCR (xxx = 3-digit sensor ID) or ModBus RTU function 0x03 in registers 40002 – 40003 in IEEE754 32-bit format at 9600 baud, 8N1).

How do I order the TA air temperature sensor?

The order code combines the model (TA with natural ventilation or TAV with forced ventilation), the outlet (A, B, C, or N), the sensor-datalogger cable (05 = CS05 of 5 m, 10 = CS10 of 10 m, xx* = CSxx, length in meters to be specified in the order), and the SSU bracket with a length of L = 700-750 mm. Manufacturer example: TA C 10 SSU. The model references are TA-N, TA-A, TA-B, TA-C, TAV-N, TAV-A, TAV-B, and TAV-C.

Under what environmental conditions does the TA air temperature sensor operate?

It operates at temperatures of -60 ÷ +80 °C, relative humidity of 0÷100% and wind speeds up to 50 m/s (gusts up to 60 m/s), with protection against polarity reversal and transients.

Properties

FeatureSpecification
Measurement and sensitive element
Measured magnitudeAir temperature
Typical measurement range-40 to +60 °C
Safety range-40 to +60 °C
Transducer typePlatinum resistance thermometer Pt100 1/3 DIN (100 Ω @ 0 °C)
Standard of the sensitive elementDIN 43760 class 1/3 DIN
PrecisionDIN 43760 1/3 DIN (±0.1°C @ 0°C)
Resolution0.01 °C
Linearity in temperature0.2 °C
Temperature repeatability0.1 °C
Response time< 10 s (63% of the variation)
VentilationNatural (code TA) or forced (code TAV)
Regulatory complianceWMO · EN 15518-3:2011 · CE
Output signals and interface
Standard output signal (N version)4-wire natural Pt100 (100 Ω @ 0 °C)
Voltage output (version A)0÷2Vdc (-40…+60 °C; °C = (V · 100) / 2 – 40)
Current output (version B)4÷20mA (-40…+60 °C; °C = (100 · (mA – 4)) / 16 – 40)
Digital output (version C)RS485 Half duplex (ASCII request xxxCR, xxx = 3-digit sensor ID) or RS485-MODBUS RTU (function 0x03, registers 40002 – 40003 IEEE754 32 bits)
RS485 communication parameters9600 baud, N parity, 8 data bits, 1 stop bit
Output impedance60÷200 Ω
Power supply, environment, and mechanical data
Feeding10÷30Vdc
ConsumptionTypical < 0.1 W · Maximum 2 W @ 12Vdc (TAV mod., forced ventilation)
Electrical protectionsAgainst polarity reversal and transients
Operating conditions-60 to +80 °C; humidity 0 to 100%; wind 50 m/s (gusts of 60 m/s)
Construction materialAluminum alloy, stainless steel screws
DimensionsØ 162 mm; height 220 mm
Weight700 g
Connector protection ratingIP68
ReferenceConfiguration
TA-ATAAModel: TA · Ventilation: Natural · Output signal: 0÷2Vdc (-40 ÷ +60 °C)
TA-BTABModel: TA · Ventilation: Natural · Output signal: 4÷20mA (-40 ÷ +60 °C)
TA-CCT scanModel: TA · Ventilation: Natural · Output signal: RS485 / ModBus RTU
SOSOModel: TA · Ventilation: Natural · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire
TAV-ATAVAModel: TAV · Ventilation: Forced · Output signal: 0÷2Vdc (-40 ÷ +60 °C)
TAV-BTAVBModel: TAV · Ventilation: Forced · Output signal: 4÷20mA (-40 ÷ +60 °C)
TAV-CTAVCModel: TAV · Ventilation: Forced · Output signal: RS485 / ModBus RTU
TAV-NTAVNModel: TAV · Ventilation: Forced · Output signal: Pt100 1/3 DIN (100 Ω @ 0 °C) 4-wire
NESA TA Air Temperature Sensor
Dimensional drawing and connector of the NESA TA air temperature sensor

Other products

ATESTEO LOGO, manufacturer of torque sensors
Inductive Transducer | Limit 5,000 N·m | 15,000 RPM | PCD Flange 155.5 mm | Accuracy 0.02% | Inertia 0.0167 kg·m²
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø4, 6 or 8 mm H7 | Housing Ø38 mm | 1 to 2540 imp/rev | NPN, PNP, push-pull, line driver | Power supply 5–30 V | IP65 shaft (IP66 Z-seal) | Tangential coupling
NESA Environmental Meters
0 ÷ 359° | Resolution 0.1° | ± 1° | 335 mm | Precision potentiometer | 0÷2Vdc, 4÷20mA, RS485 / Modbus or 10Kohm
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
SPI, TTL level, binary code | Ø 28 mm | 16-bit resolution | Ø 6 mm spindle or push-in coupling | 5 VDC (4.5 … 5.5 VDC) | IP54 / IP65 / IP67 | 14 or 16 turns (up to 5760°)
DPF Sensors logo
Differential pressure transmitter. Measuring range up to 3 MPa (30 Bar)
LVDT Manufacturer Logo Schreiber Messtechnik
OEM position transmitter for HP/LP bypass valves, turbine control valves, and steam conditioning systems
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
44 mm square flange | Shaft Ø6 h7, centered Ø20 h7 | 1–2540 imp/rev | NPN, PNP, push-pull, driver, TTL | 5–30 V | IP66 shaft (IP53 under torque) | 60 kHz (100 kHz optional)
NESA Environmental Meters
Frecuencia, 0÷2Vdc, 4÷20mA, RS485 | 0,28 ÷ 50 m/s | Primera clase (First Class) IEC 61400-12-1 | R 125 mm · 300 mm | 10 ÷ 28Vdc | Conector IP68
NESA Environmental Meters
0-1Vdc, 4-20mA, RS485 | 0-100% RH | Capacitive (thin film) | Ø 162 x 220 mm | 10-30Vdc | Natural or forced ventilation
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø78, insulated hollow shaft | Ø12, Ø15, Ø20 or Ø25 mm H7 | Insulated elastic coupling | Up to 8192 steps (13 bits) | Parallel or SSI | 5, 15, 8–24, 18–28 or 10–30 V | IP65 shaft (IP66 sealed)
Shopping Basket