S-CO Carbon Monoxide Sensor
Budget-friendly price Request a quote
4÷20mA / ModBus RS485 | CO | 0÷300 / 0÷1000 ppm | -20 ÷ 50°C | 11…30 Vdc | IP54 | 230g
- Manufacturer: Nesa
- Category: Gases - Particles, Meteorology – Climatology, SENSORS
El NESA S-CO es un sensor para la medición de la concentración de CO (monóxido de carbono) para aplicaciones industriales y ambientales, específicamente realizado para aplicaciones en exterior con grado de protección IP54.
Principio de medida electroquímico o infrarrojo (NDIR) (según el gas), rango 0÷300 ppm o 0÷1000 ppm, resolución <2 ppm y tiempo de respuesta <30 s. Salida 4÷20mA / ModBus RS485.
Key points
- Rango 0÷300 ppm o 0÷1000 ppm; resolución <2 ppm; límite de sobrecarga 2000 ppm
- Tiempo de respuesta <30 s; vida útil >120 meses
- Output 4÷20mA / ModBus RS485; power supply 11…30 Vdc; consumption < 2VA
- Rango operativo -20 ÷ 50°C; humedad 15…90 %RH sin condensación; IP54; 230 g; CE
Technical Frequently Asked Questions
What range and resolution does it have?
0÷300 ppm o 0÷1000 ppm, con resolución <2 ppm.
What exits does it have?
4÷20mA / ModBus RS485.
What is their diet and consumption like?
Power supply 11…30 Vdc and consumption < 2VA.
Properties
| Feature | Specification |
|---|---|
| Measurement and operating principle | |
| Gas | CO (monóxido de carbono) |
| Measurement principle | Electrochemical or infrared (NDIR) (depending on the gas) |
| Range | 0÷300 ppm o 0÷1000 ppm |
| Resolution | <2 ppm |
| Response time | <30 s |
| Shelf life | >120 meses |
| Overload limit | 2000 ppm |
| Exit signals | |
| Exit sign | 4÷20mA / ModBus RS485 |
| Power supply, environment, and mechanical data | |
| Feeding | 11…30 Vdc |
| Consumption | < 2VA |
| Operating range (°C) | -20 ÷ 50°C |
| Humidity | 15…90 %RH non-condensing |
| Degree of protection | IP54 |
| Use | For outdoor use |
| Dimensions | View map |
| Weight | 230 g |
| Regulatory compliance | EC |
| Reference | Configuration |
|---|---|
| S-COSCO | Output: ModBus RTU · Supply: Full scale 300 ppm or 1000 ppm, IP54, with 1 m cable |


Related documentation, cases, and guides
Other products

ST315.21, Measuring range 0 to 2,000 mS, extendable and submersible. Working range 0 to 40°C

Housing Ø104 mm, hollow shaft H7 | Torque or pivot support | 100 to 2048 impedances/revolution | NPN, PNP, push-pull, driver, TTL | Power supply 5–30 V | IP65 shaft (IP66 sealed) | CE Ex II 3GD, category 3

4 default parameters | pH 0÷14 | Level 0÷20 m | -5 ÷ +60 °C | RS485 | 10.8 ÷ 16Vdc | 512×42mm

SPI (TTL) | Ø 48 mm | Resolution up to 14 bits | Shaftless: magnetic position marker | 5 VDC (4.5 … 5.5 VDC) | IP67 / IP68 / IP69

Driving Telemetry | Stepped Range 50 – 400 N·m | Class Accuracy ±0.10% | Analog Output ±10V | 16-Bit Resolution

100 mV/g ±10% (IEPE) | 2Hz to 12kHz ±5% | ±50g | 40g | -25 to 120°C | C5015 2-pin connector | Ø19 mm base | Stainless steel, IP67

Housing Ø80, servo-type flange | Shaft Ø10 h7 | 7 to 12 bit (up to 4096 steps) | Parallel, SSI RS422 or analog | 5, 15, 8–24 or 18–28 V | IP65 shaft (IP66 with Z option) | ATEX Ex d IIC T6

Indoor CO2 sensor, range up to 4000 ppm, analog output and digital alarm

Microcontroller-based LVDT | 5 to 15 mm range | M30x1.5 and 25x25 mm housings | IP67/IP66 | Scalable outputs | Threaded/lock mounting