BAR-AV Precision Digital Barometer

Budget-friendly price Request a quote
Modbus RS485 · Modbus TCP-IP · RS232 | 500÷1200 hPa | ±0.15 hPa @ +20°C | Capacitive transducer | 200 x 110 x 60mm | 10.8÷15Vdc | IP67

The NESA BAR-AV is a precision digital barometer for absolute pressure, QNH, QFE, and QFF, with a capacitive transducer (1 to 3), IP67 painted metal enclosure, and WMO and ICAO standards. Typical measurement range 500–1200 hPa and accuracy ±0.15 hPa at +20°C.

Modbus RS485, Modbus TCP/IP (EthL LAN) and RS232 auto-transmission outputs, with web interface and display. References: BAR-AV (one transducer) and BAR-AV-S (three transducers). For AWOS stations, airport meteorology, aviation and navigation, and industrial and environmental monitoring.

Key points

  • Typical measurement range 500÷1200 hPa, resolution 0.01 hPa, time constant ~ 2 s
  • Accuracy ±0.15 hPa at +20°C; ±0.20 hPa from -40 to +60°C; long-term stability <±0.1 hPa/year
  • Linearity and hysteresis < ±0.1 hPa, overpressure limit 3000 hPa
  • Modbus RS485, Modbus TCP-IP, RS232 auto forwarding, socket, FTP
  • 10.8÷15Vdc, <0.9 W (~ 45 mA @ 12Vdc), reverse polarity and transient protection
  • IP67, -40 ÷ +80°C (screen -20 ÷ +60°C), ~ 700 g, 200 x 110 x 60 mm

Technical Frequently Asked Questions

What measurement principle does the BAR-AV use?

It uses a capacitive principle absolute pressure transducer (1 to 3), automatically temperature compensated by a 3D algorithm.

What is the difference between BAR-AV and BAR-AV-S?

The BAR-AV has one transducer and the BAR-AV-S has three. Both include a calibration report and a 2.5 m cable.

How can the data be accessed?

Data can be accessed via the instrument's own web pages (numerical and graphical format, without external software), RS232 (automatically sending every 1 second), RS485 Modbus, TCP/IP Modbus, socket, or FTP. Internal memory stores one to three years of data in ASCII or CSV format.

Properties

FeatureSpecification
Measurement and operating principle
Measured magnitudeAbsolute pressure, QNH, QFE, QFF
Measurement principleCapacitive, temperature compensated with 3D algorithm
Transducers1 (BAR-AV); 3 (BAR-AV-S)
Typical measurement range500÷1200 hPa
Linearity< ±0.1 hPa
Hysteresis< ±0.1 hPa
Resolution0.01 hPa
Accuracy at +20°C±0.15 hPa
Extended total accuracy±0.20 hPa (-40…+60 °C)
Calibration uncertainty±0.25 hPa
Time constant~ 2 s
Long-term stability<±0.1 hPa/year
Overpressure limit3000 hPa
Regulatory complianceEC; CIMO/ET-Stand-1/Doc.10 (20.XI.2012) WMO-2012; WMO and ICAO
Output signals and interface
Exit signModbus RS485; Modbus TCP-IP, Lan Eth; auto send RS232, socket, FTP
RS232 Auto-SendEvery 1 second
Web interfaceConfiguration and display in numeric and graphical format via the 10/100 MBps LAN port (in addition to the keyboard), without external software
Internal memoryOne to three years of data, in ASCII or CSV format
QNH and QFF temperatureStandard (15 °C) or actual air temperature, with sensor connected
Power supply, environment, and mechanical data
Feeding10.8÷15Vdc
Consumption<0.9 W (~45 mA @ 12Vdc)
ProtectionsPolarity reversal and transients
Operating conditions-40 ÷ +80°C [0÷100 RH]; display: -20 ÷ +60°C
EnvelopePainted metal, IP67
ConnectorsTwo IP68 resin connectors: one 4-wire and one 7-wire
Dimensions200 x 110 x 60 mm (see drawing)
Weight~ 700 g
CalibrationCalibrated and verified in a climate chamber; 3D matrix calibration system on standard primary reference; calibration report valid for one year from the first active configuration
Supply configurationCalibrated, tested, and configured for continuous transmission over RS232
ReferenceConfiguration
BAR-AVBARAVTransducers: 1 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable
BAR-AV-SBARAVSTransducers: 3 · Supply: 500÷1200 hPa, with display; automatic calculation of QNH and QFE; web interface; Modbus RS485, Modbus TCP-IP (Lan Eth) and RS232 auto-send; calibration report and 2.5 m cable
NESA BAR-AV Digital Barometer
Dimensions and connections of the NESA BAR-AV digital barometer

Other products

Dimetix_AG-1
Quick Start Package, Power and Connectivity Laser Range: Comprehensive equipment for interactive bench setups and preliminary testing
B&C Electronics – Italian manufacturer of industrial water sensors and analyzers
Measuring range 0-4,000/40,00/400,0 Nephelometric method (USEPA 180.1) with 2200 K tungsten lamp. Lamp life 100,000h
DPF Sensors logo
PSX PRESSURE. Liquids.
LVDT Manufacturer Logo Schreiber Messtechnik
LVDT Sensor | Ranges 5mm, 10mm, 15mm | Outputs 0/4-20mA, 0/10VDC, ±10V | IP66 Waterproof | Infinite Resolution | Accuracy up to 0.25%
Monitran-Logo
Industrial eddy current probe | Linear range 0 – 12 mm | Sensitivity 1.4 mV/µm nominal | DC to 10 kHz | M30 thread, Ø25 mm | -30 °C to 180 °C (probe) | Power supply -24VDC @ 30mA
DPF Sensors logo
Pressure switch
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø58, shaft Ø10 h7 | Up to 1024 steps (10 bits) | Parallel, SSI or analog (mA or V) | 5, 15, 8–24, 18–28 or 10–30 V | IP54 shaft (IP65 sealed) | Gray or Excess
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø38 mm, spindle Ø6.35 h7 | 8192 steps/revolution (13 bits) | SSI (RS422), natural binary | Power supply 5 V, 5–30 or 10–30 V | IP64 spindle (IP66 sealed) | 12000 rpm with low torque (option B) | Impacts 100 G (6 ms)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø50, shaft Ø6 h7 | Up to 256 steps (8 bits) | Parallel NPN open collector | 5, 15, 8–24, 18–28 or 10–30 V | IP65 shaft (IP66 sealed) | Gray, Excess or custom | Option NPN 70 mA with PTC