SSI TH1 Rod Magnetostrictive Transducer

Magnetostrictive | SSI 24 and 25 bit | Stroke 50 … 4250 mm | Resolution 1, 5 or 10 µm | Linearity ≤ ±25 … ±120 µm | 13 … 34 VDC | 350 bar · IP67 / IP68

Novotechnik TH1 SSI magnetostrictive transducer. NOVOSTRICTIVE technology, non-contact.

Magnetostrictive rod transducer for non-contact linear position measurement. Stroke from 50 to 4250 mm. Working pressure up to 350 bar. Passive annular position marker. Depending on the interface, it measures up to three positions and speed.

Key points

  • Position detection with ring placeholder
  • Unlimited mechanical life
  • Resolution down to 1 µm, independent of length
  • Temperature coefficient ≤ 15 ppm/K

Technical Frequently Asked Questions

What can be connected to the SSI TH1 magnetostrictive transducer?

It can be connected to Novotechnik M12 connectors and cables, Novotechnik M16 connectors and cables, and Novotechnik linear sensor positioners (magnets and cursors).

How do I order the SSI TH1 magnetostrictive transducer?

The order code has six fields: stroke (mm), mechanical version, interface, signal, resolution, and code and connection. For example, TH1-0800-102-211-102 is the version with an 800 mm electrical range, M18x1.5 threaded flange with a 30 mm zero point, 24-bit SSI, binary code with 5 µm resolution, and an 8-pin M12x1 connector. All the options for each field are available in the order code configurator on this page.

Under what conditions does the SSI TH1 magnetostrictive transducer operate?

Operating temperature: -40 … +85 °C. Protection: IP67.

Properties

FeatureSpecification
Description
HousingAnodized aluminum AlMgSi0.5 F22, 3.3206.71
Threaded flangeStainless steel X2CrNiMoN 18-14-3, 1.3952
RodStainless steel X6CrNiMoTi 17-12-2, 1.4571
MountingM18x1.5 bushing for threaded plug drill according to ISO 6149; 3/4"-16UNF bushing for threaded plug drill according to SAE J475
PlaceholderRing placeholder
Measurement principleNOVOSTRICTIVE, non-contact magnetostrictive
Electrical connectionM12x1 connector with 4, 5 or 8 poles, shielded; M16x0.75 (IEC 130-9) connector with 6 or 8 poles, shielded; 8x 0.25 mm² PUR cable, shielded, 1, 3 or 5 m
ElectronicsSMD with integrated ASIC; the connector housing (display) is bonded to the sensor housing; the housing is capacitively decoupled from the electronics
Mechanical data
Electrical range (L dimension)0050 … 4250 mm in 25 mm increments; other lengths available upon request
Maximum operating speed with valid output signal10 m/s
Maximum operating acceleration with valid output signal200 m/s²
IEC 60068-2-27 Shock100 g (11 ms), one stroke
Vibration IEC 60068-2-620 g (5 … 2000 Hz, Amax = 0.75 mm)
DIN EN 60529 protection, with fixed connectorIP67
DIN EN 60529 protection, with cableIP68
LifeMechanically unlimited
Working temperature-40 … +85 °C
Storage temperature-40 … +100 °C
Working humidity0 … 95 % HR (non-condensing)
Working pressure≤ 350 bar
Pressure spikes≤ 600 bar
Bursting pressure> 700 bar
Electrical data
Electrical range (L dimension)0050 … 4250 mm
Protocol24-bit and 25-bit SSI (26-bit on request)
TicketsRS422
Monoflop time™30 µs
CodingGray, binary
Sampling frequency (update)< 750mm: 2kHz; 750 … < 2000 mm: 1 kHz; > 2000mm: 0.5kHz; extrapolated to 16 kHz
Resolution (LSB)1, 5 or 10 µm (other resolutions available upon request)
Absolute linearity (*), length < 250 mm≤ ±25 µm
Absolute linearity (*), length < 750 mm≤ ±30 µm
Absolute linearity (*), length < 1000 mm≤ ±50 µm
Absolute linearity (*), length < 2500 mm≤ ±80 µm
Absolute linearity (*), length up to 4250 mm≤ ±120 µm
Electrical zero point tolerance±0.5 mm
Reproducibility (rounded to the LSB)≤ 6 µm
Hysteresis (rounded to the LSB)≤ 4 µm
Temperature error≤ 15 ppm/K (min. 0.01 mm/K)
Supply voltage24 (13 … 34) VDC
Power supply voltage ripple≤ 10 % Ub
Overvoltage protection40 VDC (permanent)
Current consumption≤ 100 mA
Reverse polarity protectionYes, up to the maximum supply voltage.
Short circuit protectionYes (outputs to GND and supply voltage up to 7V)
Ohmic load at the outlets> 120 Ω
Max clock frequency.2 MHz
Insulation resistance (500 VDC)≥ 10 MΩ
Safety and compliance
MTTF (IEC 60050)347 years
AccordanceEC
Electromagnetic compatibility
EN 61000-4-2Electrostatic discharges (ESD) 4 kV, 8 kV
EN 61000-4-3Electromagnetic fields 10 V/m
EN 61000-4-4Fast transients (burst) 1 kV
EN 61000-4-6Conducted disturbances induced by RF fields 10 V rms.
EN 61000-4-8Magnetic fields at industrial frequency 3 A/m
EN 55011Radiated disturbances, class B
OptionMeaning
Example: TH1-0800-102-211-102 = 800 mm electrical range, M18x1.5 threaded flange with zero point at 30 mm, 24-bit SSI, binary code with 5 µm resolution and 8-pole M12x1 connector.
1. Electrical range (mm)
0050 … 4250Standard, 25 mm increments; other lengths available upon request
2 · Mechanical version
102M18x1.5 threaded flange, zero point at 30 mm
1033/4"-16UNF threaded flange, zero point at 30 mm
104M18x1.5 threaded flange, zero point at 51 mm
1053/4"-16UNF threaded flange, zero point at 51 mm
106M18x1.5, zero point at 30 mm, with end support (*)
1073/4"-16UNF, zero point at 30 mm, with end support (*)
108M18x1.5, zero point at 51 mm, with end support (*)
1093/4"-16UNF, zero point at 51 mm, with end support (*)
3 · Electrical interface
2SSI
4 · SSI output signal (2__)
1SSI 24 bit
2SSI 25 bit
7SSI 26 bit (25 = alarm, 26 = even parity), on request
5 · Synchronous serial interface (2__)
1Binary code; resolution 5 µm
2Gray code; 5 µm resolution
4Binary code; resolution 1 µm
5Gray code; resolution 1 µm
7Binary code; resolution 10 µm
8Gray code; resolution 10 µm
6. Electrical connection
101Connector M16x0.75 (IEC 130-9), 8 poles
102M12x1 connector, 8 poles
103Connector M16x0.75 (IEC 130-9), 6 poles
108M16x0.75 connector (IEC 130-9), 7-pin (SSI only)
2018-wire cable, shielded, 1 m
2038-wire cable, shielded, 3 m
2058-wire cable, shielded, 5 m
The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference.
Novotechnik TH1 Analog Rod Magnetostrictive Transducer
Dimensional drawing of the Novotechnik TH1 analog rod magnetostrictive transducer

Other products

Transit time ultrasonic flow meter
HIGH temperature transducer
Industrial LOW pressure transducer
Electromagnetic flowmeter
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Potentiometric or analog | Thread Ø 0.51 mm | Stroke 200, 500 or 750 mm | Pot. 1 kΩ, 4–20 mA, 0–10 V, 0–5 V | Electronic power supply 5, 12 or 24 V ±5 % | Linearity ±0.25 % fs | IP54
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø12–25 mm insulated | Housing Ø90 mm | 1 to 18000 impedances/revolution | NPN, PNP, push-pull, line driver | Power supply 5–30 V | IP65 shaft (IP66 sealed) | Elastic, compensates ±2 mm axial
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
B10 flange mounting Ø115 mm | Turned metal housing Ø86 mm | Ø11 h7 stainless steel shaft | 1 to 3600 rpm | NPN, PNP, push-pull, line driver | 5–30 V power supply | IP67 on the shaft side
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
80 mm square flange | 80 mm housing | 8 mm h7 stainless steel shaft | 1 to 25,000 rpm | NPN, PNP, push-pull, driver, 1 Vpp | 5–30 V power supply | IP65 shaft (IP66 sealed)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Ø10 h7 shaft | 63.5 mm square flange | 1 to 1024 imp/revolution | NPN, PNP, push-pull or driver | 5–30 V power supply | IP65 shaft (IP66 Z-seal) | 60 kHz (100 kHz optional)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
B10 flange Ø115, shaft Ø11 h7 | SSI with preset, RS422 | Up to 65536 steps (16 bits) | Gray or binary programmable | 10–30 V | IP64 shaft (IP66 sealed) | Optional Sin/Cos 1024 or RS422 16384 ppr

Request a quote or technical information

Please tell us the quantity you need to measure, the range, the accuracy, the output signal, or any other requirements of your application.

We will help you select the right equipment and send you a quote or technical documentation.

You can also contact us by phone:

91 764 21 00

Shopping Basket