Budget-friendly price Request a quote
Wire diameter 0.51 mm | Stroke 200, 500 or 750 mm | Potentiometric output (divider) | Potentiometer 1 kΩ | Incremental 0.1 mm (5 or 24 V) | Linearity ±0.25 % fs | IP50

The ELCIS F3A is a linear transducer using 0.51 mm diameter wire, with a stroke of 0 to 750 mm and a potentiometric output (voltage divider) of 1 kΩ or incremental. Patented manufacturing.

The potentiometer (W) has infinite resolution, a temperature coefficient of ±100 ppm/°C, and a useful voltage divider range of ~3% to 97%. The incremental (I) has a resolution of 0.1 mm (x4), a maximum stroke of 200 mm, and a power supply of 5 V (line-driven) or 24 V (push-pull). It has a maximum linearity error of ±0.25% fs, a repeatability of ±0.15% fs, and a maximum reading speed of 1 m/s.

Stainless steel cable, 0.51 mm diameter, and fiberglass-reinforced plastic housing; pull-out forces <4.5 N and retraction forces <3.5 N; impact resistance of 50 G x 11 ms and vibration resistance of 12 G (10 ÷ 2000 Hz). IP50 protection rating for potentiometer and mechanical components; output depends on the connection. Connection via 1 m cable (CV) or 2 m incremental cable (CVK), or cable end connector (VM, TM, VL, TL, VD, VH, VH5, VI, VE, VK, TK, VN, VH6, VM5, VM9, VS, VD5).

  • Nominal careers of 200 mm, 500 mm and 750 mm, with stainless steel cable Ø 0.51 mm.
  • Exit 1 kΩ potentiometric (infinite resolution) or incremental of 0.1 mm (only with max. stroke 200 mm, 5 V line-driver or 24 V push-pull and A, S or D fixing).
  • Extraction force <4.5 N and retraction <3.5 N.
  • Fixation N (without a set square) or TO, D and S (with square and upper thread exit, right or left); options G (spring hitch with pulley) and M (magnetic fixation).
  • Connection cable 1 to 5 m or connector at the end of the cable; IP50 in potentiometer and mechanics.

Technical Frequently Asked Questions

What types of output does the F3A transducer offer?

It offers a potentiometric output of 1 kΩ (W) with infinite resolution or an incremental output (I) with a resolution of 0.1 mm (x4), the latter only with a max. stroke of 200 mm, 5 V (line-driver) or 24 V (push-pull) power supply and A, S or D fixing.

What are the available nominal career paths?

The preferred values are 200 mm (020), 500 mm (050), 750 mm (075).

What mechanical mounting options does it include?

It can be installed without a bracket (fixing N) or with a bracket and upper (A), right (D) or left (S) wire exit.

Properties

FeatureSpecification
Mechanics
Nominal stroke0 ÷ 750 mm (200, 500 and 750 mm)
Cable length1 m (standard), 2, 3, 4 and 5 m
Weight125 g; 200 g (incremental)
Cable and housingStainless steel cable Ø 0.51 mm · fiberglass reinforced plastic casing
Electric
Output electronics1 kΩ potentiometer (W) · Incremental (I)
ResolutionInfinite (potentiometer); 0.1 mm (incremental, x4)
Incremental feeding5 Vcc ±5% (line-driver) · 24 Vdc ±5% (push-pull)
Linearity / maximum repeatability.±0.25 % fs / ±0.15 % fs (customizable upon request)
Protection and environment
Maximum reading speed1 m/s
Degree of protectionPotentiometer: IP50 • Mechanical: IP50 • Output: according to connection
Impact/vibration resistance50 G x 11 ms / 12 G (10 ÷ 2000 Hz)
Operating/storage temperature-20 ÷ +80 °C / -30 ÷ +80 °C (customizable upon request)
Other features
Forces on the cableExtraction <4.5 N • Retraction <3.5 N
PotentiometerThermal coefficient ±100 ppm/°C • Useful range of the voltage divider ~3 % ÷ 97 %
ELCIS F3A Linear Wire Transducer
Dimensional drawing of the ELCIS F3A linear cable transducer

Related documentation, cases, and guides

Other products

SI 31012 conductivity probe (4 electrodes) with Pt100 – DN40 DIN 11851-52 – 5 m cable
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Servo flange Ø44 mm, shaft Ø6 h7 | 8 to 2048 bpm/rotation | Line driver 26LS31/ET7272, NPN | Power supply 5, 8–24, 18–28, 10–30, 5–30 V | IP66 shaft (IP53 with low torque) | 12000 rpm with low torque (option B) | Impacts 100 G (6 ms)
DPF Sensors logo
Radar level measurement for dams and open channels
Dimetix_AG-1
Spare Part Kit for Dimetix D Series Laser Sensors | Cable glands and M16x1.5 nuts | Terminal blocks | Maintains IP65 protection rating | Made in Switzerland
DPF Sensors logo
COMPACT pressure transducer, low pressure.
Monitran-Logo
Industrial eddy current probe | Linear range 0 – 8.5 mm | Sensitivity 2 mV/µm nominal | DC to 10 kHz | EP340: M24 thread, Ø20 mm | EP340F: Ø40 mm body with 3 holes | -30 °C to 180 °C (probe)
Encardio Rite vibrating wire sensors and geotechnical instrumentation
Vibrating wire piezometer for pore pressure (interstitial water pressure) and groundwater level | Ranges 0.2 to 10 MPa | Accuracy ±0.25 % FS
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø38 mm, shaft Ø6.35 h7 | 8 to 2048 bpm | Line driver 26LS31/ET7272, NPN | Power supply 5, 8–24, 18–28, 10–30, 5–30 V | IP64 shaft (IP66 sealed) | 12000 rpm with low torque (option B) | Impacts 100 G (6 ms)
B&C Electronics – Italian manufacturer of industrial water sensors and analyzers
Industrial pH electrode, 0–12 pH, double PTFE junction, polymer gel, PVDF body, DL connection and 3/4″ NPT mounting. Up to 100 °C and 10 bar.
Transit time ultrasonic flow meter
Shopping Basket