Thread displacement sensor: when to use it and how to choose the stroke

Technical guide · GUEMISA

Quick response

A wire displacement sensor is the logical choice when measuring linear positions between a few hundred millimeters and several tens of meters, and installing a rigid scale of the same length is not feasible or cost-effective. To select the stroke length, take the actual machine travel, add a margin of approximately 10%, and verify that the linearity error, expressed as a percentage of the full scale, remains acceptable at that length.

Unlike a rod or ruler transducer, the wire only works in tension: the sensor is fixed at a point, the end of the wire is hooked onto the moving element, and the travel is measured by pulling the wire out and collecting it.

The thread is wound onto a drum attached to an encoder or potentiometer: the length extracted is the position of the part.

How a wire sensor works

Inside the housing is a stainless steel wire wound around a drum. A return spring keeps the wire taut and retracts it when the moving element returns. The drum is coupled to a measuring element, and the output signal changes depending on which element is used.

  • Potentiometer: the drum shaft moves a cursor along a resistive track. The output is a proportional resistance (voltage divider) and the resolution is theoretically infinite.
  • Potentiometer with electronics: the same track, with a module that converts the signal to 4…20 mA, 0…10 V or 0…5 V.
  • Incremental encoder: generates A, B, and Z pulses. The control system counts the pulses from a reference, and the resolution is the displacement per pulse.
  • Absolute encoder: delivers the position directly via SSI, PROFIBUS-DP, CANopen or DeviceNet, so the position is not lost when power is removed.

When is a wire sensor appropriate?

Long runs

This is their natural domain. Among GUEMISA's products, DPF Sensors' DLE-L sensors cover distances from 6 to 12 m, the ELCIS EF13I reaches 10, 15, 20, 25, or 30 m, the EF19I 40, 50, or 60 m, and the HPS-LX series indicates ranges from 11,000 to 35,000 mm. For such long distances, a ruler or a magnetostrictive sensor of the same length would be difficult to transport and install.

Misaligned mounting

Unlike a rigid rod, the wire sensor does not require the sensor axis to be perfectly parallel to the direction of movement. It simply needs to extend in the direction of travel. Each connector specifies the wire's exit conditions; adhere to these during installation, as a wire rubbing against the exit hole will shorten the cable's lifespan and inaccurate the measurement.

A single fixing point

Simply attach the sensor body and the end of the wire. It is convenient for use on cranes, lifting platforms, gates, long-stroke hydraulic cylinders, and test benches.

Speed and acceleration of the thread

These are the two limits that are most often overlooked. If the permissible acceleration is exceeded, the thread slackens and then tightens suddenly again. When sizing, compare with the maximum values in the data sheet:

ProductCareerMaximum thread speedMax acceleration.
ELCIS F5A, F7A (potentiometer)500 to 2000 mm1 m/snot indicated in the data sheet
DPF Sensors DLE-L6 to 12 m1 m/snot indicated in the data sheet
ELCIS F600S (absolute SSI)up to 6 m4 m/s2.5 G
ELCIS EF13I10 to 30 m4 m/s2.5 G
ELCIS EFK300up to 3000 mm8 m/s5G
ELCIS EF500up to 5000 mm10 m/s5G

Calculate the maximum speed and acceleration (both starting and stopping) of the moving part, and discard models that do not meet these requirements. Also, consider the stated service life: the ELCIS F600 and EF13I series claim over 106 cycles at 2 m/s, and the DPF Sensors DLE, more than 1 × 106 cycles.

Which exit to choose

ExitWhat deliversWhen it fitsExample of the range
PotentiometricResistance proportional to positionSimple instrumentation, infinite resolutionELCIS F5A and F7A (1 kΩ); HPS series (5 kΩ)
4…20 mA, 0…10 V, 0…5 VStandardized analog signalPLC analog inputs; 4…20 mA supports long cablesELCIS F5C and F7C; HPS-L (4…20 mA, 0…5/10 V)
Incremental (A, B, Z)Pulses, with resolution from 0.005 mm/pulse to 1 mm/pulseRapid counters and motion controls with referenceDLE-L, DLE-HR and DLE-S from DPF Sensors; ELCIS EFK300
Absolute (SSI, PROFIBUS-DP, CANopen, DeviceNet)Coded position, resolution 0.1 or 1 mmWhen position cannot be lost after a power outageELCIS F600S, F600P, F600C, F600D

Resolution and accuracy are not the same thing. The potentiometer has infinite resolution, but a linearity of ±0.25% of full scale in the ELCIS F series, while the F600 absolute encoder is rated at ±0.05% of full scale.

How to choose a career with a margin of error

1. Measure the actual distance traveled

Measure the distance between the two extreme positions of the moving element, not the nominal length of the cylinder or guide.

2. Add margin, but not too much.

A 10% margin prevents the thread from reaching the end of the drum at the extreme positions. More margin than necessary worsens the result, because linearity is calculated over the entire stroke. With ±0.25% of the full scale, a 2000 mm sensor has a maximum error of ±5 mm; with ±0.05% over 6 m, it's ±3 mm; with ±0.04% over 5000 mm, ±2 mm.

3. Choose a standard career

Each series is manufactured for specific races. The table shows real examples:

Required routeWith a 10% marginStandard race that fitsProducts with that career
400 mm440 mm500 mmELCIS F5A, F5C
1100 mm1210 mm1250 mmELCIS F5A, F5C
1800 mm1980 mm2000 mmELCIS F7A, F7C, F7D
5 m5.5 m6 mDPF Sensors DLE-L
9 m9.9 m10 mDLE-L, ELCIS EF13I
25 m27.5 m30 mELCIS EF13I

If the value is right at the limit of a series, move on to the next one. Some series support custom races; check with us before finalizing the design.

Which GUEMISA products are a good fit?

Documentation and related cases

Frequently Asked Questions

What is the maximum stroke a sensor can measure per wire?

It depends on the series. Among GUEMISA products there are models up to 60 m (ELCIS EF19I) and the HPS-LX series indicates ranges from 11,000 to 35,000 mm.

Does the sensor need to be aligned with the movement?

Not with the precision required by a rigid rod, but the thread should emerge in the direction of travel without rubbing. Follow the instructions on the product sheet for each model.

Encoder or potentiometer?

It depends on what your system reads. The potentiometer, with or without electronics, 4–20 mA, 0–10 V, or 0–5 V, is easy to connect. The incremental encoder provides pulses for counters, and the absolute encoder retains its position even without power.

What happens if the thread suddenly comes loose?

The spring catches it quickly and can damage the thread or the reel. A secure hook that cannot come loose is recommended to prevent the thread from being released freely.

What speed can the thread handle?

In the GUEMISA datasheets, from 1 m/s in the potentiometric and DLE models up to 10 m/s in the ELCIS EF500. Always compare with the maximum speed and acceleration of your application.

Do you need help choosing?

Send us the application, race or reference you have and we will tell you the model and your order code.

Write to ventas@guemisa.com 91 764 21 00