Soil moisture sensor SUT
- Manufacturer: Nesa
- Category: Meteorology – Climatology, SENSORS, Humidity Sensors, Floor
The NESA SUT is a soil moisture sensor that detects the soil's dielectric constant using high-frequency measurements. The value responds to changes in soil moisture and is independent of salinity. It is temperature compensated and interconnectable with MCS modules.
Measurement range 0–100% VWC (ground water volume), time constant <1 s, and operating temperature -40–85°C. Standard output signal 4–20 mA (0–2 Vdc or RS485/Modbus); power supply 10–20 Vdc, 5 mA @ 12 Vdc (typical). Aluminum body, copper electrodes, 110 g.
Key points
- Measurement range 0÷100% VWC (volume of water in the ground); time constant <1 s (average time)
- High-frequency measurement of the soil's dielectric constant; non-resistive; insensitive to salinity; does not corrode over time
- Temperature compensated sensor; -40 ÷ 85°C
- Standard output signal 4÷20mA, (0÷2Vdc or RS485/Modbus); with MCS module (optional): 4÷20mA (B) or RS485 / Modbus (C)
- Power supply 10÷20 Vdc; 5mA@12Vdc (typical); protections against reverse polarity and transients
- Aluminum body, copper electrodes; 110g; Ø = 7 mm, L = 150 mm; WMO; CE; supplied with calibration report
Technical Frequently Asked Questions
What is its measurement range and time constant?
Measurement range 0÷100% VWC and time constant <1 s (average time).
What exit signals does it have?
Standard output signal 4÷20mA, (0÷2Vdc or RS485/Modbus). In the order code, A is 0÷2Vdc; B (4÷20mA) and C (RS485 Modbus) have MCS option.
What kind of diet does it need?
10÷20 Vdc, with a consumption of 5mA@12Vdc (typical), and protections against reverse polarity and transients.
Properties
| Feature | Specification |
|---|---|
| Measurement and operating principle | |
| Measured magnitude | Soil moisture in VWC (volume of water in the soil) |
| Measurement principle | Dielectric constant of the soil, measured at high frequency |
| Sensitive element | Electrodes sensitive to variations in the dielectric constant of the ground |
| Sensor type | Non-resistive |
| Measurement range | 0÷100% VWC (volume of water in the ground) |
| Time constant | <1 s (average time) |
| Salinity | Insensitive to salinity |
| Corrosion | It does not corrode over time |
| Temperature compensation | Temperature compensated sensor |
| Voltage-VWC correlation | Approximated with 4 line segments, VWC = α*V-β (see graph) |
| Calibration | It comes with a calibration report |
| Regulatory compliance | WMO; CE |
| Exit signals | |
| Standard exit sign | 4÷20mA, (0÷2Vdc or RS485/Modbus) |
| Output signal (A) | 0÷2Vdc |
| With MCS module (optional) | 4÷20mA (B) or RS485 / Modbus (C) |
| MCS Modules | Interconnectable with MCS modules |
| Power supply, environment, and mechanical data | |
| Feeding | 10÷20 Vdc |
| Consumption | 5mA@12Vdc (typical) |
| Operating temperature | -40 ÷ 85°C |
| Protections | Against polarity reversal and transients |
| Done in (body) | Aluminum |
| Performed on (electrodes) | Copper |
| Weight | 110g |
| Dimensions | Ø = 7 mm, L = 150 mm |