Class A rocker rain gauge PL1000 and PL1000R
- Manufacturer: Nesa
- Category: Rain - Snow, Meteorology – Climatology, SENSORS
The NESA PL1000 is a Class A tipping bucket rain gauge with an anodized aluminum cylindrical body and a 1000 cm² collection area. A funnel-shaped orifice with a filter directs the rainwater onto a stainless steel tipping bucket supported by a blade system, and a reed switch detects its movements, filtering out electrical and mechanical noise. The PL1000R model includes a heater for cold climates, and the MCS module normalizes the signal.
Maximum counting intensity 0÷600 mm/h, sensitivity 0.2 mm, conversion constant 0.2 mm/imp. and average accuracy ±2% @30mm/h (±0.10mm/min). Output N by reed dry contact pulses, A 0÷2Vdc, B 4÷20mA and C RS485 / Modbus; power supply 10÷30Vdc.
Key points
- Class A according to UNI 11452:2012 and UNI 17277:2020; WMO standards and CE regulations
- Capture area 1000 cm²; sensitivity 0.2 mm; conversion constant 0.2 mm/imp.
- Maximum counting intensity 0÷600 mm/h; average accuracy ±2% @30mm/h (±0.10mm/min)
- Output N: pulses by dry reed contact (R < 250 Ω; switching time < 10 ms); outputs A, B and C with 0÷100 mm accumulation and auto-reset at 100 mm
- Power supply 10÷30Vdc; PL1000R heater max. 60W@12Vdc with integrated temperature control system
- Operating conditions 0 ÷ 80°C (-40 ÷ +80°C with heater); 3.5kg with stand
Technical Frequently Asked Questions
What intensity and precision does it have?
Maximum counting intensity 0÷600 mm/h with average accuracy ±2% @30mm/h (±0.10mm/min). At outputs A, B, and C, the measurement is an accumulated count of 0÷100 mm with automatic reset at 100 mm.
What exits does it have?
N: pulses by dry reed contact (R < 250 Ω). With MCS module: A 0÷2Vdc, B 4÷20mA and C RS485 / Modbus with standard ID 010.
What food and what temperature does it support?
Power supply 10÷30Vdc, typical consumption 4÷20mA in A, B and C. Operating conditions 0 ÷ 80°C; the PL1000R, with heater of max. 60W@12Vdc, -40 ÷ +80°C.
Properties
| Feature | Specification |
|---|---|
| Measurement and operating principle | |
| Measured magnitude | Precipitation |
| Class | According to UNI 11452:2012 and UNI 17277:2020 |
| Transducer type | Stainless steel rocker arm with magnetic reed switch |
| Switching time | < 10 ms |
| Catchment area | 1000 cm² |
| Conversion constant | 0.2 mm/imp. |
| Sensitivity | 0.2 mm |
| Measurement range (N) | Unlimited reed contact |
| Measurement range (A, B, C) | Accumulated 0÷100 mm with auto-reset at 100 mm |
| Maximum counting intensity | 0÷600 mm/h |
| Average accuracy | ±2% @30mm/h (±0.10mm/min) |
| Regulatory compliance | WMO standards and CE standards |
| Exit signals | |
| Exit N | Reed dry contact impulses (R < 250 Ω) |
| Output A (with MCS module) | 0÷2Vdc (0÷100 mm) |
| Output B (with MCS module) | 4÷20mA (0÷100 mm) |
| Output C (with MCS module) | RS485 / Modbus, Standard ID 010 |
| Output resistance | 100mΩ / 1MΩ |
| Power supply, environment, and mechanical data | |
| Feeding | 10÷30Vdc |
| Typical consumption (A, B and C) | 4÷20mA |
| Heater power supply (PL1000R) | Max. 60W@12Vdc |
| Temperature control (PL1000R) | Integrated temperature control system |
| Protections | Polarity reversal and transient protection; anti-bounce circuit |
| Operating temperature | 0 ÷ 80°C |
| Temperature with heater (PL1000R) | -40 to +80°C |
| Material | Anodized anticorodal aluminum alloy, painted white; stainless steel rocker arm |
| Flange | For posts with a max. diameter of 59/80 mm |
| Weight | 3.5kg with stand |
| Reference | Configuration |
|---|---|
| PL1000-APL1000A | Heater: No · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000-BPL1000B | Heater: No · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000-CPL1000C | Heater: No · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000-NPL1000N | Heater: No · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied: With flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-APL1000RA | Heater: Max. 60 W, with integrated temperature control system · Output: 0÷2Vdc (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-BPL1000RB | Heater: Max. 60 W, with integrated temperature control system · Output: 4÷20mA (0÷100 mm) · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |
| PL1000R-CPL1000RC | Heater: Max. 60 W, with integrated temperature control system · Output: RS485 / Modbus, Standard ID 010 · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for poles of max. Ø 59/80 mm and calibration report |
| PL1000R-NPL1000RN | Heater: Max. 60 W, with integrated temperature control system · Output: Pulses · Class A according to: UNI 17277:2020 calibration procedure · Supplied with: Flange for posts of max. Ø 59/80 mm and calibration report |


Related documentation, cases, and guides