Modular datalogger with Linux Evolution-M

Budget-friendly price Request a quote
8-32 differential inputs @24bit | 5 digital inputs | Linux with Apache web server | USB, RS232, RS485, Ethernet | -40 to +70°C | IP20 | 200 x 110 x 74.5 mm

The NESA Evolution-M is a modular datalogger with a Linux operating system, Apache web server and PHP interpreter, usable without external or proprietary software and configurable via web browser, with access via Ethernet, WiFi, USB, serial and remote.

Analog inputs 8 ÷ 32 differential or 16 ÷ 64 common @24bit, 5 digital inputs, 4 analog outputs @12bit and 4 open collector digital outputs, operating temperature -40 ÷ +70°C, typical consumption <1W (<1.5W with GPRS), 200x110x74.5mm and 700g.

Key points

  • Analog inputs 8 ÷ 32 differential or 16 ÷ 64 common @24bit; ranges -100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V, 0÷20mA, 4÷20mA and 4-wire Pt100
  • 5 digital inputs for frequency (max. 5000Hz), status (On/Off) or count
  • 4 analog outputs @12bit 0÷2Vdc (convertible with the MCS option) and 4 open collector digital outputs (50V, 200mA, 5000Hz)
  • 2 RS232, 1 RS485, 2 USB host, 1 MiniUSB slave, 1 10/100 Ethernet LAN, SDI-12 slave and I2Cbus
  • Power supply 10.5 ÷ 24Vdc from solar panel or wind generator, 10.8 ÷ 15Vdc from battery, 24Vac, 110Vac or 220Vac with external power supply; typical consumption <1W (<1.5W with GPRS)
  • 500MHz ARM Cortex A8; 128MB NAND + 128MB RAM internal memory; external USB memory up to 512GB or external HD up to 1TB
  • -40 to +70°C non-condensing; IP20; 200x110x74.5mm; 700g; polycarbonate and painted metal case, green version

Technical Frequently Asked Questions

What ports does the Evolution-M have?

8 ÷ 32 analog differential or 16 ÷ 64 common @24bit, with ranges -100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V, 0÷20mA, 4÷20mA and Pt100 4 wires, and 5 digital inputs in frequency (max. 5000Hz), status (On/Off) or count.

What exits does it have?

4 analog outputs @12bit 0÷2Vdc, convertible with the MCS option, and 4 open collector digital outputs (50V, 200mA, 5000Hz); in addition, a 12Vdc max. 5A power output and another controllable one.

What communication ports does it have?

2 RS232 (9 pin), 1 RS485, 2 USB host, 1 MiniUSB slave, 1 Ethernet LAN 10/100 Base T RJ45, SDI-12 slave and I2Cbus.

Properties

FeatureSpecification
Tickets and measurement
Differential inputs8 ÷ 32 @24bit
Common entrances16 ÷ 64 @24bit
Food entrances12Vdc@250mA on each input
Reference voltage2.048Vdc at each input
Voltage ranges-100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V
Current ranges0÷20mA, 4÷20mA
Temperature probePt100 4-wire
Monitor @12bit2 inputs, battery and primary power
Auxiliaries @12bit3 inlets, internal pressure and auxiliary measurement
Digital tickets5, in frequency (max. 5000Hz), state (On/Off) or count
Series entries1 ÷ 200 via RS485, RS232, SDI-12, configurable via web
Radio tickets1 ÷ 100 depending on the radio module, configurable via web
Sampling interval<100μS
Validate sample1 ÷ 10 s programmable
Process and/or shipment1 s ÷ 1440min, predefined steps
AccuracyVerified according to UNI CEI EN 13005, cat. A
Exit signals
Analog outputs4 @12bit, 0÷2Vdc
Analog outputs with MCS optionConvertible to 0÷1Vdc, 0÷5Vdc, 0÷10Vdc, 0÷20mA, 4÷20mA, RS485 or RS485-ModBus
Digital outputs4 programmable, open collector, ON/OFF
Maximum voltage50V (digital outputs)
Maximum current200mA (digital outputs)
Maximum frequency5000Hz (digital outputs)
Power output1, 12Vdc max. 5A
Controllable output1, 12Vdc max. 5A
Power supply, environment, and mechanical data
External power supply24Vac, 110Vac, 220Vac
Solar or wind10.5 ÷ 24Vdc, from solar panel or wind generator
Battery10.8 ÷ 15Vdc
Charge regulatorIntegrated, for sealed cyclic batteries, max. 5A continuous
Load control4-phase dual-level floating; PWM according to IEC 21-6/3
Charging indicatorIntegrated LED
Typical consumption<1W
GPRS consumption<1.5W with GPRS
Working temperature-40 to +70°C, non-condensing
Dimensions200x110x74.5mm
Degree of protectionIP20
BoxIP65 – IP67, made of standard polyester or stainless steel, 300x400x220mm, models TMF-ALPS, TMF AL220 or TMF-ALPS+220
Weight700g
MaterialPolycarbonate and painted metal case, green version
Communication and programming
RS2322 (9 pin)
RS4851
USB host2 (12Mb/s) @500mA
MiniUSB slave1 (480MB/s)
Ethernet LAN1, 10/100 Base T RJ45
SDI-121, slave (1÷100 connections)
I2Cbus1
Local interface24×2 LCD Screen
Supported protocolsModbus RTU and TCP, TCP-IP, HTTP, FTP, SFTP, NTP, Telnet, SMTP, Socket, I2CBus, SDI-12, RS232/485 command line, SNMP, MQTT, IoT (Lora, SigFox)
Data formatsASCII txt, Excel, CSV, XML, email, AES encryption
ProgrammingLocal via LAN cable and remote via GPRS modem, WiFi, satellite, modem or radio; requires a web browser, XML configurator or text editor
Processing and memory
ProcessorARM Cortex A8 500MHz, 32bit
Operating systemEmbedded Linux, kernel 2.6.37, with Apache web server
Internal memory4MB NOR Flash (core); 128MB NAND + 128MB RAM (programs, user programs and level I and II data)
External memoryMemoria USB o memoria Flash de 8GB ÷ 512GB (-40°C+60°C), suministrada como datos de nivel III, o HD o SSD
Maximum capacity512GB USB drive; 1TB external hard drive
Memory managementCyclical (overwrites the oldest)
StorageUnencrypted (ASCII characters) or encrypted with a 256-bit hash key
Internal clockResolution 1ms, accuracy ±3 minutes per year; adjustment by NTP server (requires internet or LAN) or GPS
Watch batteryLithium, 3.6Vdc
Programmable timesIndependent acquisition, processing, storage and transmission, from 1 minute to 24 hours
Algorithms includedPunto de rocío (Magnus Tetens), presión de vapor, intensidad de precipitación, precipitación horaria, precipitación diaria, QNH, QFE, evapotranspiración potencial (Penman Motheith), heliofanía (Angström-Prescott), sensación térmica (wind chill), humidex
Protections and diagnosis
Internal protectionProtection against short circuits and indirect discharges, with EMC filters
Overcurrent6A interchangeable fuse
External protectionIn M2Ch modules, ESD type ±3 kV according to IEC 61000–4-2
Analog channelsInternal EMC filters on each channel
Digital tickets5KVrms opto-isolation
PortsEMC filters on communication ports
Watch dog3 levels (1 hardware, 2 software) + status LED
DiagnosisAccording to ISO14230, three levels of restoration
Integrated monitorsBattery, primary power supply and pressure (e-Bar)
Applications and standards
SectorsHydrology, meteorology, roads, agrometeorology, wind energy, forests, landslides, geotechnics, microclimate, industry, landfills, photovoltaics
StandardsEC WMO, EN-13005, ISO-13528, CEI-21-6/3, IEC-61400-12, ISO-9060, Legislative Decree 121/2020, DE 2018/850, CE-128/2009
ReferenceConfiguration
Evolution-MEvolutionMDescription: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD.
Modular datalogger with Linux system and NESA Evolution-M web server
Dimensions of the NESA Evolution-M datalogger

Other products

DPF Sensors logo
Amplifier for proportional solenoid valves, voltage regulation (speed)
DPF Sensors logo
Thermocouple converter and Pt100, Pt500, Pt1000, Ni100. 2, 3 or 4 wires, programmable via PC
DPF Sensors logo
2-way universal galvanic isolator/converter. Input: mV (DC), Wirelessly configurable ranges (0/10mV…10V), Automatic 0-4/20mA output (Active/Passive), Power supply: 10…30 VDC
NESA Environmental Meters
500–1100 hPa | Automatic QNH Calculation | 0.4 hPa @ 20°C | Piezoresistive Bridge | RS485 Digital | 10–30 Vdc | IP65 Plastic Enclosure
DPF Sensors logo
4/20mA signal isolator duplicator, *** INPUT: ACTIVE/PASSIVE *** OUTPUTS: 2X 4/20mA active, 24VDC (20.. 30V) isolated
DPF Sensors logo
Comparator of the greater or lesser of 2 – 3 or 4 4/20mA or 0…10 Vdc signals.
DPF Sensors logo
Voltage output converter with amplified current
DPF Sensors logo
Galvanic isolator. Wireless configuration, Input: 0/10V – 0-4/20mA – 0/4K resistance, 10 linearization steps, Isolated 4/20mA output (Active/Passive) automatic, Power supply: 24VDC (10.. 30V)
DPF Sensors logo
Multiplexer for 4 or 8 3-wire Pt100 or Pt1000 probes at the output of the same probe
DPF Sensors logo
AC current relay. Overload / underload
Shopping Basket