Modular datalogger with Linux Evolution system
- Manufacturer: Nesa
- Category: Data Logger, INSTRUMENTATION
El NESA Evolution es un datalogger modular con sistema operativo Linux, servidor web Apache e intérprete PHP, utilizable sin software externo ni propietario y configurable mediante navegador web, con acceso por Ethernet, WiFi, USB, serie y en remoto.
Entradas analógicas 8 ÷ 32 diferenciales o 16 ÷ 64 comunes @24bit, 5 entradas digitales, 4 salidas analógicas @12bit y 4 salidas digitales de colector abierto, temperatura de trabajo -40 ÷ +70°C, consumo típico <1W, 200x110x74,5mm y 700g.
Key points
- Analog inputs 8 ÷ 32 differential or 16 ÷ 64 common @24bit; ranges -100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V, 0÷20mA, 4÷20mA and 4-wire Pt100
- 5 digital inputs for frequency (max. 5000Hz), status (On/Off) or count
- 4 analog outputs @12bit 0÷2Vdc (convertible with the MCS option) and 4 open collector digital outputs (50V, 200mA, 5000Hz)
- 2 RS232, 1 RS485, 2 USB host, 1 MiniUSB slave, 1 10/100 Ethernet LAN, SDI-12 slave and I2Cbus
- Alimentación 10,5 ÷ 24Vdc desde panel solar o generador eólico, 10,8 ÷ 15Vdc desde batería, 24Vac, 110Vac o 220Vac con alimentador externo; consumo típico <1W
- 500MHz ARM Cortex A8; 128MB NAND + 128MB RAM internal memory; external USB memory up to 512GB or external HD up to 1TB
- -40 ÷ +70°C sin condensación; IP20; 200x110x74,5mm; 700g; policarbonato y aluminio anodizado
Technical Frequently Asked Questions
¿Qué entradas tiene el Evolution?
8 ÷ 32 analog differential or 16 ÷ 64 common @24bit, with ranges -100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V, 0÷20mA, 4÷20mA and Pt100 4 wires, and 5 digital inputs in frequency (max. 5000Hz), status (On/Off) or count.
What exits does it have?
4 analog outputs @12bit 0÷2Vdc, convertible with the MCS option, and 4 open collector digital outputs (50V, 200mA, 5000Hz); in addition, a 12Vdc max. 5A power output and another controllable one.
What communication ports does it have?
2 RS232 (9 pin), 1 RS485, 2 USB host, 1 MiniUSB slave, 1 Ethernet LAN 10/100 Base T RJ45, SDI-12 slave and I2Cbus.
Properties
| Feature | Specification |
|---|---|
| Tickets and measurement | |
| Differential inputs | 8 ÷ 32 @24bit |
| Common entrances | 16 ÷ 64 @24bit |
| Food entrances | 12Vdc@250mA on each input |
| Reference voltage | 2.048Vdc at each input |
| Voltage ranges | -100÷100mV, -2÷2Vdc, 0÷100mV, 0÷2V, 0÷5V, 0÷10V |
| Current ranges | 0÷20mA, 4÷20mA |
| Temperature probe | Pt100 4-wire |
| Monitor @12bit | 2 inputs, battery and primary power |
| Auxiliaries @12bit | 3 inlets, internal pressure and auxiliary measurement |
| Digital tickets | 5, in frequency (max. 5000Hz), state (On/Off) or count |
| Series entries | 1 ÷ 200 via RS485, RS232, SDI-12, configurable via web |
| Radio tickets | 1 ÷ 100 depending on the radio module, configurable via web |
| Sampling interval | <100μS |
| Validate sample | 1 ÷ 10 s programmable |
| Process and/or shipment | 1 s ÷ 1440min, predefined steps |
| Accuracy | Verified according to UNI CEI EN 13005, cat. A |
| Exit signals | |
| Analog outputs | 4 @12bit, 0÷2Vdc |
| Analog outputs with MCS option | Convertible to 0÷1Vdc, 0÷5Vdc, 0÷10Vdc, 0÷20mA, 4÷20mA, RS485 or RS485-ModBus |
| Digital outputs | 4 programmable, open collector, ON/OFF |
| Maximum voltage | 50V (digital outputs) |
| Maximum current | 200mA (digital outputs) |
| Maximum frequency | 5000Hz (digital outputs) |
| Power output | 1, 12Vdc max. 5A |
| Controllable output | 1, 12Vdc max. 5A |
| Power supply, environment, and mechanical data | |
| External power supply | 24Vac, 110Vac, 220Vac |
| Solar or wind | 10.5 ÷ 24Vdc, from solar panel or wind generator |
| Battery | 10.8 ÷ 15Vdc |
| Charge regulator | Integrated, for sealed cyclic batteries, max. 5A continuous |
| Load control | 4-phase dual-level floating; PWM according to IEC 21-6/3 |
| Charging indicator | Integrated LED |
| Consumption | Típico <1W |
| Working temperature | -40 to +70°C, non-condensing |
| Dimensions | 200x110x74,5mm (ver plano) |
| Degree of protection | IP20 |
| Box | IP65 – IP67, made of standard polyester or stainless steel, 300x400x220mm, models TMF-ALPS, TMF AL220 or TMF-ALPS+220 |
| Weight | 700g |
| Material | Policarbonato y aluminio anodizado, versión azul o gris |
| Communication and programming | |
| RS232 | 2 (9 pin) |
| RS485 | 1 |
| USB host | 2 (12Mb/s) @500mA |
| MiniUSB slave | 1 (480MB/s) |
| Ethernet LAN | 1, 10/100 Base T RJ45 |
| SDI-12 | 1, slave (1÷100 connections) |
| I2Cbus | 1 |
| Local interface | 24×2 LCD Screen |
| Supported protocols | HTTP, HTTPS, FTP, FTPS, Modbus RTU y TCP-IP, Telnet, SMTP, Socket, I2Cbus, SDI-12, SNP |
| Data formats | ASCII txt, Excel, email, AES cifrado |
| Programming | Local via LAN cable and remote via GPRS modem, WiFi, satellite, modem or radio; requires a web browser, XML configurator or text editor |
| Processing and memory | |
| Processor | ARM Cortex A8 500MHz, 32bit |
| Operating system | Embedded Linux, kernel 2.6.37, with Apache web server |
| Internal memory | 4MB NOR Flash (core); 128MB NAND + 128MB RAM (programs, user programs and level I and II data) |
| External memory | Memoria USB o memoria Flash de 8GB ÷ 512GB (-40°C+60°C), suministrada como datos de nivel III, o HD o SSD |
| Maximum capacity | 512GB USB drive; 1TB external hard drive |
| Memory management | Cyclical (overwrites the oldest) |
| Storage | Unencrypted (ASCII characters) or encrypted with a 256-bit hash key |
| Internal clock | Resolution 1ms, accuracy ±3 minutes per year; adjustment by NTP server (requires internet or LAN) or GPS |
| Watch battery | Lithium, 3.6Vdc |
| Programmable times | Independent acquisition, processing, storage and transmission, from 1 minute to 24 hours |
| Algorithms included | Punto de rocío (Magnus Tetens), presión de vapor, intensidad de precipitación, precipitación horaria, precipitación diaria, QNH, QFE, evapotranspiración potencial (Penman Motheith), heliofanía (Angström-Prescott), sensación térmica (wind chill), humidex |
| Protections and diagnosis | |
| Internal protection | Protection against short circuits and indirect discharges, with EMC filters |
| Overcurrent | 6A interchangeable fuse |
| Polaridad y transitorios | Protección contra inversión de polaridad y supresor de transitorios |
| External protection | In M2Ch modules, ESD type ±3 kV according to IEC 61000–4-2 |
| Analog channels | Internal EMC filters on each channel |
| Digital tickets | 5KVrms opto-isolation |
| Ports | EMC filters on communication ports |
| Watch dog | 3 levels (1 hardware, 2 software) + status LED |
| Diagnosis | According to ISO14230, three levels of restoration |
| Integrated monitors | Battery, primary power supply and pressure (e-Bar) |
| Applications and standards | |
| Sectors | Hydrology, meteorology, roads, agrometeorology, wind energy, forests, landslides, geotechnics, microclimate, industry, landfills, photovoltaics |
| Standards | EC WMO, EN-13005, ISO-13528, CEI-21-6/3, IEC-61400-12, ISO-9060, Legislative Decree 121/2020, DE 2018/850, CE-128/2009 |
| Reference | Configuration |
|---|---|
| EvolutionEvolution | Description: Proprietary software, fully configurable via web interface, customizable with user scripts and programs shared over the network. Versatile and accurate multi-channel and multi-user datalogger for analog, digital, frequency, and serial signals. Basic configuration: 8 differential inputs or 16 common inputs, 5 digital inputs, 4 digital outputs, 4 analog outputs, 7 configurable communication ports (2xUSB, 2xRS232, 1xEthernet, 1xSDI12, 1xRS485). 24-bit accuracy on all AC/DC inputs. Multiple power sources: solar panel, 12Vdc battery, or external power supply; typical consumption <1W. Internal charger. Three levels of memory: internal, external, and USB memory up to 512 GB or external hard drive. 2 x 24 character LCD, DIN rail mount. |


Related documentation, cases, and guides
Other products







