PT100 PT1000 RTD Replicator with galvanic isolation PTi-1000
Having trouble duplicating a PT100 or PT1000 signal? Attempting to split a sensor signal using direct taps or jumpers often leads to instability, reading errors due to impedance loading, and risks of dough loops.
He ITAIA PTi-1000 RTD replicator generates independent real resistances at each output, allowing a single sensor to simultaneously feed a PLC, a SCADA and a recorder with complete galvanic independence and without altering the original signal.
Its design is particularly suitable for pulsed or multiplexed measurement systems, where many standard isolators do not maintain a stable reading against the excitation current of the PLC or acquisition system.
Technological advantages for engineering
- High precision: Typical error of 0.02 % (≈0.05 °C), suitable for critical processes.
- Complete galvanic isolation: Separation between input, outputs and power supply for maximum noise immunity.
- Sensor versatility: Compatible with PT100, PT500, PT1000, Ni100, KTYxx and resistive signals.
- Security in classified areas: Available in certified versions ATEX / IECEx (Ex ia).
Available in versions DH, SH, XD and XS, with resistive output configurations, analog signals 4-20 mA / 0-10 V and display option OLED for local monitoring.
Thanks to your 16-bit resolution, high EMC immunity and compatibility with connections of 2, 3 and 4 threads, The PTi-1000 is a reliable solution for industrial applications where it is required to distribute an RTD signal without loss of accuracy.
Properties
| Function | Galvanically isolated true resistance RTD replicator/duplicator |
| Tickets | RTD / resistance |
| Compatible sensors | PT100, PT500, PT1000, Ni100, KTxx |
| Probe connection | 2, 3 and 4 threads |
| Cable compensation | Yes, in a 2-wire configuration |
| Resistance output range | 30 Ω … 9.5 kΩ |
| Number of exits | 2 or 4, depending on the version |
| Versions | DH / SH / XD / XS |
| Analog outputs | According to version: 0/4-20 mA and 0-10 V |
| Typical accuracy | 0,02 % |
| Resolution | 16 bits |
| Input-output delay | < 0.5 s |
| Pulsed/multiplexed measurement | Compatible with pulsed and multiplexed measurement systems |
| Galvanic isolation | Galvanic isolation at inlet, outlets and power supply |
| ATEX Certification | Intrinsically safe version available Ex ia |
| Feeding | 10 … 30 V AC/DC |
| Consumption | < 1.2 W (OLED) / 2.5 W peak |
| Working temperature | -30 … +50 °C |
| Degree of protection | IP20 |
| Mounting | DIN rail EN 60715 |
| Dimensions | 22 x 92 x 69 mm / 22 x 92 x 93 mm, depending on the version |
| Screen | OLED 64×48, depending on the version |
| Regulations | CE, EN61010-1, EN61000-3/2,-6/1.3, Ex ia option |


Other products