M12 connectors and cables
- Manufacturer: Novotechnik
- Category: Novotechnik Accessories, Connectors and cables
Novotechnik M12 connectors and cables. M12x1 female connectors with cable or for mounting, T-splitter and termination resistor for sensors with M12 connection.
Key points
- Straight or angled female connector
- With PUR cable (2, 5 or 10 m, free end) or with screw terminals for mounting
- Shielded and unshielded versions
- 5-pin CAN-Bus accessories: female/male cable, T-splitter and 120 Ω termination resistor
Technical Frequently Asked Questions
Which sensors do M12 connectors and cables use?
They are used with IPX-7900 (heavy-duty rotary potentiometer), LWG (swivel-joint stem potentiometer transducer), LWX-003 (IP67 swivel-joint potentiometer transducer), LWX-004 (IP67 potentiometer transducer, protected stem), MB1-3600 (multi-turn magnetic absolute encoder (CANopen, IO-Link, SAE J1939)), MC1-2800 (multi-turn magnetic absolute encoder (CANopen, IO-Link, ratiometric, SAE J1939)), MZ1-2200 (miniature multi-turn magnetic encoder (CANopen, IO-Link, ratiometric, SAE J1939)), RFC-4800 (non-contact angle sensor (analog, CANopen, incremental, IO-Link, SAE J1939, SPI, SSI)), RFX-6900 (non-contact magnetic angle sensor contact (analog, CANopen)), RMB-3600 (multi-turn magnetic absolute encoder (analog, SSI)), RSB-3600 (single-turn non-contact magnetic angle sensor (analog, incremental)), RSC-2800 (non-contact magnetic angle sensor (analog, incremental, SPI, SSI)), RSM-2800 (non-contact magnetic multi-turn encoder (analog, SPI, SSI)), RSX-7900 (non-contact magnetic angle sensor (analog, CANopen)), TF1 (non-contact inductive transducer (analog, CANopen, IO-Link, SSI)), TH1 (magnetostrictive linear transducer for hydraulic cylinder (analog, CANopen, pulses, IO-Link, SSI)), TM1 (magnetostrictive transducer with plug-in or threaded flange (analog, CANopen, SAE J1939)) and TP1 (profile magnetostrictive linear transducer (analog, CANopen, pulses, incremental, IO-Link, SSI).
What types of M12 connectors and cables are there?
The following types are available: straight female with cable (EEM-33-32/62/97, EEM-33-35/36/37, EEM-33-49/50/51 and EEM-33-86/90/92); angled female with cable (EEM-33-33/63/99, EEM-33-38/39/40 and EEM-33-87/91/93); angled female for mounting (EEM-33-89); straight female/male with cable, CAN-Bus (EEM-33-52); straight female with cable, CAN-Bus (EEM-33-41/43); straight female for mounting, CAN-Bus (EEM-33-73); angled female for mounting, CAN-Bus (EEM-33-75); T-distributor, CAN-Bus (EEM-33-45) and 120 Ω termination resistor, CAN-Bus (EEM-33-47).
How do I order M12 connectors and cables?
For example, EEM-33-32 (Art. 400005600): straight female connector with cable, 4 pins, 2 m. All order references with their Art. are listed in the reference table on this page.
Properties
| Feature | Specification |
|---|---|
| EEM-33-32/62/97 · Straight female with cable | |
| Pins | 4 |
| Screened | Yeah |
| Cable / connection | PUR, max. Ø 6 mm |
| Temperature | -25…+80 °C while moving · -50…+80 °C stationary |
| Threads | PP, 0.34 mm² |
| It is used with | IPX-7900, MC1-2800, MZ1-2200, RMB-3600, RSB-3600, RSC-2800, RSM-2800, TM1 |
| EEM-33-33/63/99 · Female angled with cable | |
| Pins | 4 |
| Screened | Yeah |
| Cable / connection | PUR, max. Ø 6 mm |
| Temperature | -25…+80 °C while moving · -50…+80 °C stationary |
| Threads | PP, 0.34 mm² |
| It is used with | LWX-003, LWX-004, RMB-3600, RSB-3600, TM1 |
| EEM-33-35/36/37 · Straight female with cable | |
| Pins | 4 |
| Screened | No |
| Cable / connection | PUR, max. Ø 6 mm |
| Temperature | -40…+85 °C fixed |
| Threads | PP, 0.34 mm² |
| It is used with | MC1-2800, MZ1-2200, TH1, TP1, MB1-3600, RFC-4800, RFX-6900, RSX-7900, TF1, TM1 |
| EEM-33-38/39/40 · Female angled connector with cable | |
| Pins | 4 |
| Screened | No |
| Cable / connection | PUR, max. Ø 6 mm |
| Temperature | -40…+85 °C fixed |
| Threads | PP, 0.34 mm² |
| It is used with | TH1, TP1, MB1-3600, RFX-6900, RSX-7900, TF1, TM1 |
| EEM-33-89 · Female angled fitting for mounting | |
| Pins | 4 |
| Screened | Not screenable |
| Cable / connection | For cable 6…8 mm, max. 0.75 mm² |
| Temperature | -25…+90 °C |
| It is used with | LWG, LWX-003, LWX-004, RFX-6900, RSX-7900, TM1 |
| EEM-33-52 · Straight female/male cable, CAN-Bus | |
| Pins | 5 |
| Screened | Yes (screen on the knurling) |
| Cable / connection | PUR, Ø 6.7 mm |
| Temperature | -25…+90 °C connector -20…+80 °C cable |
| Threads | PE, 2×0.25 + 2×0.34 mm² |
| It is used with | MC1-2800, MZ1-2200, MB1-3600, RFC-4800, RFX-6900, RSX-7900, TF1, TM1 |
| EEM-33-41/43 · Straight female connector with cable, CAN-Bus | |
| Pins | 5 |
| Screened | Yeah |
| Cable / connection | PUR, Ø 7.2 mm |
| Temperature | -25…+85 °C fixed |
| Threads | PP, 2×0.25 + 2×0.34 mm² |
| It is used with | TH1, TP1, RFC-4800, RFX-6900, RSX-7900, TF1 |
| EEM-33-49/50/51 · Straight female with cable | |
| Pins | 5 |
| Screened | Yes (screen on the knurling) |
| Cable / connection | PUR, Ø 6.7 mm |
| Temperature | -25…+90 °C connector -20…+80 °C cable |
| Threads | PE, 2×0.25 + 2×0.34 mm² |
| It is used with | MC1-2800, MB1-3600, TM1, TF1 |
| EEM-33-73 · Straight female for mounting, CAN-Bus | |
| Pins | 5 |
| Screened | Screenable |
| Cable / connection | For cable 6…8 mm, max. 0.75 mm² |
| Temperature | -40…+85 °C |
| It is used with | TH1, TP1, MB1-3600, RFC-4800, RFX-6900, RSX-7900, TF1 |
| EEM-33-75 · Female right-angle mount, CAN-Bus | |
| Pins | 5 |
| Screened | Screenable |
| Cable / connection | For cable 6…8 mm, max. 0.75 mm² |
| Temperature | -40…+85 °C |
| It is used with | TH1, TP1, RFC-4800, RFX-6900, RSX-7900, TF1 |
| EEM-33-45 · T-splitter, CAN-Bus | |
| Pins | 5 |
| Temperature | -25…+85 °C |
| It is used with | TH1, TP1, MB1-3600, RFC-4800, RSX-7900, TF1, TM1 |
| EEM-33-47 · Termination resistor 120 Ω, CAN-Bus | |
| Pins | 5 |
| Temperature | -25…+85 °C |
| It is used with | MC1-2800, MZ1-2200, TH1, TP1, MB1-3600, RFC-4800, RSX-7900, TF1, TM1 |
| EEM-33-86/90/92 · Straight female with cable | |
| Pins | 8 |
| Screened | Yeah |
| Cable / connection | PUR, max. Ø 8 mm |
| Temperature | -25…+80 °C while moving · -50…+80 °C stationary |
| Threads | PP, 0.25 mm² |
| It is used with | TH1, TP1, RFC-4800, RMB-3600, RSB-3600, RSC-2800, RSM-2800, TF1 |
| EEM-33-87/91/93 · Female angled connector with cable | |
| Pins | 8 |
| Screened | Yeah |
| Cable / connection | PUR, max. Ø 8 mm |
| Temperature | -25…+80 °C while moving · -50…+80 °C stationary |
| Threads | PP, 0.25 mm² |
| It is used with | TH1, TP1, RMB-3600, RSB-3600, TF1 |
| Reference | Configuration |
|---|---|
| EEM-33-32EEM3332 | Art. 400005600 · Type: Straight female with cable, 4 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-33EEM3333 | Art. 400005601 · Type: Female right-angle connector with cable, 4 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-35EEM3335 | Art. 400056135 · Type: Straight female with cable, 4 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-36EEM3336 | Art. 400056136 · Type: Straight female with cable, 4 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-37EEM3337 | Art. 400056137 · Type: Straight female with cable, 4 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-38EEM3338 | Art. 400056138 · Type: Female right-angle connector with cable, 4 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-39EEM3339 | Art. 400056139 · Type: Female right-angle connector with cable, 4 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-40EEM3340 | Art. 400056140 · Type: Female right-angle connector with cable, 4 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-41EEM3341 | Art. 400056141 · Type: Straight female with cable, CAN-Bus, 5 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-43EEM3343 | Art. 400056143 · Type: Straight female with cable, CAN-Bus, 5 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-45EEM3345 | Art. 400056145 · Type: T-splitter, CAN-Bus, 5 pins · Protection: IP68 |
| EEM-33-47EEM3347 | Art. 400056147 · Type: 120 Ω Termination Resistor, CAN-Bus, 5 pins · Protection: IP67 |
| EEM-33-49EEM3349 | Art. 400106368 · Type: Straight female with cable, 5 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-50EEM3350 | Art. 400106371 · Type: Straight female with cable, 5 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-51EEM3351 | Art. 400106372 · Type: Straight female with cable, 5 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-52EEM3352 | Art. 400106373 · Type: Straight female/male cable, CAN-Bus, 5 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-62EEM3362 | Art. 400005609 · Type: Straight female with cable, 4 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-63EEM3363 | Art. 400005610 · Type: Female right-angle connector with cable, 4 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-73EEM3373 | Art. 400005645 · Type: Straight female for mounting, CAN-Bus, 5 pins · Protection: IP67 |
| EEM-33-75EEM3375 | Art. 400005646 · Type: Female right-angle mount, CAN-Bus, 5 pins · Protection: IP67 |
| EEM-33-86EEM3386 | Art. 400005629 · Type: Straight female with cable, 8 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-87EEM3387 | Art. 400005630 · Type: Female right-angle connector with cable, 8 pins · Cable length: 2 m · Protection: IP67 |
| EEM-33-89EEM3389 | Art. 400005634 · Type: Female right-angle mounting, 4 pins · Protection: IP67 |
| EEM-33-90EEM3390 | Art. 400005635 · Type: Straight female with cable, 8 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-91EEM3391 | Art. 400005636 · Type: Female right-angle connector with cable, 8 pins · Cable length: 5 m · Protection: IP67 |
| EEM-33-92EEM3392 | Art. 400005637 · Type: Straight female with cable, 8 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-93EEM3393 | Art. 400005638 · Type: Female right-angle connector with cable, 8 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-97EEM3397 | Art. 400005650 · Type: Straight female with cable, 4 pins · Cable length: 10 m · Protection: IP67 |
| EEM-33-99EEM3399 | Art. 400005696 · Type: Female right-angle connector with cable, 4 pins · Cable length: 10 m · Protection: IP67 |