KELLER ECO2 Digital Pressure Gauge
KELLER ECO2 digital pressure gauge for measuring and checking pressure in industrial installations. Ranges: 0…31 bar absolute and 0…300 bar. Accuracy ≤ ±0.5% FS at 20…25 °C. Operates on a replaceable 3V CR2430 lithium battery.
Two-line LCD display with two rows of 4.5 digits. Shows the current pressure and the maximum recorded value. Pressing the ENTER button displays the minimum value measured since the last RESET for five seconds.
Instrument characteristics
Piezoresistive pressure sensor, isolated and encapsulated. Measurement frequency: 2 measurements per second. The pressure connection and diaphragm are made of AISI 316L stainless steel. IP65 protection rating.
Available ranges
- ECO2 31 bar: 0…31 bar absolute, resolution 0.01 bar, maximum overload 60 bar.
- ECO2 300 bar: 0…300 bar, resolution 0.1 bar, maximum overload 400 bar.
The 31 bar version comes from the factory with a zero setting at absolute vacuum (0 bar). The ZERO SET function establishes a zero relative to ambient pressure.
The 300 bar version has a reference point of 1 bar absolute.
Accuracy and temperature
- Accuracy at 20…25 °C: ≤ ±0.5% FS. Includes nonlinearity, pressure hysteresis, lack of repeatability, and zero and amplification deviations.
- Total error band at 0…50 °C: ≤ ±1.0 % FS.
- Long-term stability: ≤ ±0.2% FS per year, under reference conditions.
- Annual recalibration recommended by KELLER when traceability is required.
Functions
- RESET: sets the minimum and maximum values to the current pressure.
- ZERO SET: sets the applied pressure as the new zero reference.
- ZERO RESET: restores the factory zero setting.
- MIN/MAX: displays the minimum and maximum measured values.
- OFF: manual shutdown.
- CONT ON: disables automatic shutdown.
- CONT OFF: activates automatic shut-off after approximately 15 minutes without pressing.
- BAT LOW: Low battery warning.
- Overflow and underflow warning on screen (OFL and UFL).
- Overload warning: the last valid value flashes when the measurement range is exceeded.
Pressure units
The unit is selected using the two front buttons. Available units:
- bar
- amber
- hPa
- kPa
- MPa
- PSI
- kp/cm²
The settings are retained after turning off the pressure gauge.
Pressure connection
Instrument connection: 7/16-20 UNF male. Supplied with a swivel adapter with a G1/4 male connection. The swivel has O-rings and allows the pressure gauge to be rotated to adjust the display. Maximum adapter torque: 50 Nm.
Optional adapters without orientation function: G1/8, 1/4-18 NPT and G1/4 according to EN 837.
Feeding
CR2430 3V lithium coin cell battery, factory installed and included. Battery life: up to 1,000 hours of continuous operation.
Temperatures
- Compensated temperature range: 0…50 °C.
- Medium temperature: −10…60 °C.
- Ambient temperature: 0…50 °C.
- Storage temperature: −20…70 °C.
Applications
- Pressure checks in industrial installations.
- Maintenance and technical service.
- Temporary supervision of hydraulic and pneumatic circuits.
- Checking valves, regulators and pressurized equipment.
- Pressure control in machines and auxiliary equipment.
- Supervision of glass bottle filling processes.
- Replacement of analog pressure gauges with digital indication.
- Recording of minimum and maximum values during a test.
Contents of the supply
- KELLER ECO2 digital pressure gauge.
- Renata CR2430 lithium battery installed.
- Swivel G1/4 male adjustable adapter.
- Copper gasket for G1/4 connection.
- Instruction manual.
References
- 303060.0001: KELLER ECO2, range 0…31 bar absolute.
- 303060.0002: KELLER ECO2, range 0…300 bar.
Optional accessories: protective rubber case, carrying bag and KELLER calibration certificates with 5 or 11 measurement points.
ECO2-Ei version for areas with risk of explosion
The standard ECO2 is not suitable for potentially explosive atmospheres. For these areas, the intrinsically safe KELLER ECO2-Ei is available in 31 and 300 bar versions, with ATEX and IECEx certification.
Properties
| Model and operation | |
|---|---|
| Manufacturer | KELLER Pressure |
| Model | ECO2 |
| Guy | Compact battery-powered digital pressure gauge |
| Measurement principle | Piezoresistive pressure sensor, isolated and encapsulated |
| Communication interface | None |
| Data logging | It does not have a recorder; it only memorizes the minimum and maximum values since the last RESET |
| Pressure ranges | |
| ECO2 range / 31 bar | 0…31 bar absolute, PAA |
| Zero adjustment, version 31 bar | 0 bar absolute, empty; a relative zero can be set using ZERO SET |
| ECO2 range / 300 bar | 0…300 bar, PA |
| Zero adjustment, 300 bar version | Factory reference at 1 bar absolute |
| Maximum overload, 31 bar version | 60 bar |
| Maximum overload, 300 bar version | 400 bar |
| Measurement range reservation | ≥ ±10 % with display of valid values outside the nominal range |
| Accuracy and performance | |
| Accuracy at 20…25 °C | ≤ ±0.5 % FS |
| Parameters included in accuracy | BFSL nonlinearity, hysteresis, lack of repeatability, zero deviations, and amplification |
| Total error band at 0…50 °C | ≤ ±1.0 % FS |
| Long-term stability | ≤ ±0.2 % FS per year, under reference conditions |
| Measurement frequency | 2 measurements per second |
| Resolution, range of 31 bar | 0.01 bar |
| Resolution, range of 300 bar | 0.1 bar |
| Recommended recalibration interval | Annually when the application requires maintaining traceability and specified performance |
| Screen | |
| Screen type | two-line LCD |
| Ability | Two rows of 4.5 digits |
| LCD dimensions | 27.8 × 30.0 mm |
| Height of the upper digits | 8 mm |
| Height of lower digits | 7 mm |
| Upper indication | Current pressure |
| Lower indication | Maximum or minimum value measured since the last RESET |
| Functions | |
| MIN/MAX | Display of the minimum and maximum recorded values |
| RESET | Set the minimum and maximum values to the current pressure. |
| ZERO SET | Set the applied pressure as the new zero reference. |
| ZERO RESET | Restores the factory-set zero point |
| Automatic shut-off | After approximately 15 minutes without a pulse |
| Continuous operation | Yes, using the CONT ON function. |
| Low battery warning | BAT LOW Indication |
| Off-screen notice | OFL for overflow and UFL for underflow |
| Overload warning | The last valid value flashes when the measurement range is exceeded. |
| Pressure units | |
| Configurable units | bar, mbar, hPa, kPa, MPa, PSI and kp/cm² |
| Temperature | |
| Compensated range | 0…50 °C |
| Medium temperature | -10…60 °C |
| Ambient temperature | 0…50 °C |
| Storage temperature | -20…70 °C |
| Feeding | |
| Battery | CR2430 lithium, 3V |
| Battery included | Yes, Renata CR2430 installed |
| Autonomy | Up to 1,000 hours of continuous operation |
| Pressure connection | |
| Instrument connection | 7/16-20 UNF male |
| Connection to the process included | G1/4 Male Swivel Adapter |
| Orientation | Rotating adapter for orienting the screen in the reading position |
| Maximum adapter torque | 50 Nm |
| Optional adapters | G1/8, 1/4-18 NPT and G1/4 EN 837 without swivel function |
| Materials | |
| Pressure connection | AISI 316L stainless steel |
| Separating membrane | AISI 316L stainless steel |
| Internal transducer gasket | Without an internal board |
| Internal transmission fluid | Silicone oil |
| Swivel adapter insert | Nickel-plated brass |
| Swivel Joints | NBR |
| Adapter | Galvanized steel |
| adapter outer gasket | NBR |
| Screen housing | Polyamide |
| Dimensions and protection | |
| Dimensions without case | 59 × 95 × 32 mm |
| Dimensions with protective case | 70 × 101 × 42 mm |
| Approximate weight | 125g, without case or adapter |
| Degree of protection | IP65 |
| Accordance | |
| Electromagnetic compatibility | Directive 2014/30/EU |
| CEM Standards | EN IEC 61326-1, EN IEC 61326-2-3 and applicable EN IEC 61000-6 series |
| Protection against explosive atmospheres | Not in the standard ECO2; select the ECO2-Ei model |
| Order references | |
| ECO2 / 31 bar | 303060.0001 |
| ECO2 / 300 bar | 303060.0002 |
| Supplies and accessories | |
| Standard content | Pressure gauge, CR2430 battery, G1/4 swivel adapter, copper gasket, and manual |
| Optional accessories | Protective rubber cover and carrying bag |
| Optional certificates | KELLER calibration certificate with 5 or 11 measurement points |


Related documentation, cases, and guides