AF500 Wired Linear Transducer

Budget-friendly price Request a quote
Absolute, Gray or BCD output | Stroke up to 5000 mm | Resolution 0.1 or 1 mm | 5 V ±5 %, 8–24 V or 18–28 V | IP64 | Accuracy ±0.2 mm | Max. frequency 25 kHz

The ELCIS AF500 is an absolute wired linear transducer with a useful stroke of up to 5000 mm, Gray or BCD output code, max. resolution of 0.1 mm and IP64 protection rating with CM6 or SM6 connections.

It uses an LED light source (life ≥ 100,000 h) and push-pull phototransistor sensors; it offers a resolution of 0.1 mm or 1 mm, an accuracy of ±0.2 mm, and a maximum frequency of 25 kHz, with up/down switching. Its maximum reading speed is 10 m/s and its maximum acceleration is 5 G, with cable forces of 7.3 N on extension and 3.2 N on retraction.

Stainless steel shaft (h7) and bearings (ABEC 5), with a bearing life of 1.5 × 10⁹ revolutions. Operates from 0 to +70 °C (other temperatures available upon request) and can be stored from -30 to +85 °C. Standard output stages: NPN open collector 10 mA, KK NPN open collector 70 mA, KP NPN open emitter 70 mA, and B Push-Pull 70 mA. Application notes: Do not abruptly release the cable, do not exceed the maximum stroke, do not drag it over sharp surfaces, do not lubricate it, and do not open the transducer.

  • Race up to 5000 mm and accuracy of ±0.2 mm.
  • Resolution of 0.1 mm either 1 mm with code output Gray or BCD.
  • Maximum reading speed of 10 m/s and max. acceleration of 5G.
  • Output stages: NPN 10 mA, NPN 70 mA, open issuer NPN 70 mA and Push-Pull 70 mA.
  • Protection IP64 with CM6 or SM6 connection; CDH connection axial only.

Technical Frequently Asked Questions

What measurement range and resolutions does the AF500 linear cable transducer offer?

It offers a standard stroke of up to 5000 mm with resolutions of 0.1 mm (code 100) and 1 mm (code 1000).

What are the available exit codes and exit stages?

Gray code (G) or BCD (D), with up/down switching, and standard stages NPN open collector 10 mA, KK NPN open collector 70 mA, KP NPN open emitter 70 mA or B Push-Pull 70 mA.

What connection options and level of protection does it offer?

IP64 protection with CM6 or SM6 connection. Axial connections CDH, CM6 and SM6 and radial connections CM6 and SM6 (CDH: standard DC37P connector; CM6: PTO2A18-32P; SM6: PTO2E18-32P). Power supply (5), (824) or (1828): 5 V ±5%, 8÷24 V or 18÷28 V.

Properties

FeatureSpecification
Mechanics
Maximum useful stroke.5000 mm
Exit stagesStandard: NPN open collector 10 mA · KK: NPN open collector 70 mA · KP: NPN open emitter 70 mA · B: Push-Pull 70 mA
Weightapprox. 2050 g
Bearing life1.5 × 10⁹ revolutions
Electric
Resolution0,1 mm, 1 mm
Exit codeGray or BCD; up/down switching
Max frequency.25 kHz
Feeding5 V ±5 % · 8÷24 V · 18÷28 V
Consumption400÷1000 mA
Precision±0.2 mm
Protection and environment
Max speed / acceleration.10 m/s / 5 G
Degree of protectionIP64 (with CW, CM, CL, VL, SL, CM6, SM6 connections)
Operating/storage temperature0 ÷ +70 °C (another one on request) / -30 ÷ +85 °C
Other features
Forces on the cableMax. extraction 7.3 N • Max. retraction 3.2 N
ConnectionsAxial (CDH, CM6, SM6) or radial (CM6, SM6)
ReferenceConfiguration
AF500-G-1000-5-KK-CDH-RAF500G10005KKCDHRGray code · 1 mm · 5 V ±5 % · output stages: KK · DC37P connector; axial output only · radial output: cm6, sm6 connections
AF500-G-100-5-KK-CDH-RAF500G1005KKCDHRGray code · 0.1 mm · 5 V ±5 % · output stages: KK · DC37P connector; axial output only · radial output: cm6, sm6 connections
Other combinations of resolution, power supply, electronics and connection are available upon request: please contact us and we will confirm the exact reference.
ELCIS AF500 Wired Linear Transducer
Dimensional drawing of the ELCIS AF500 linear cable transducer

Related documentation, cases, and guides

Other products

LVDT Manufacturer Logo Schreiber Messtechnik
Amplified LVDT inductive sensor | Strokes 100 and 200 mm | Square housing 30×30 mm | Outputs 0/4–20 mA, 0–10 V and ±10 V | Linearity 0.25 % / 0.5 % | IP67 with suitable connector | Integrated electronics
Humidity and temperature recorder
DPF Sensors logo
Anemometer with direct alarm output (adjustable) via relay contact. Also available with 4 to 20 mA output.
LVDT Manufacturer Logo Schreiber Messtechnik
LVDT inductive sensor | Strokes 5, 10, 15 and 20 mm | Housing Ø10 mm | Linearity 0.25 % / 0.5 % | IP67 M12 / IP68 cable | Moving core or spring-loaded probe | External electronics
DPF Sensors logo
Wire displacement sensor, ranges from 100 mm to 1200 mm, with output signal in 5 Kohm resistance, 0-5 / 10 Vdc, 4-20 mA, RS485 or pulses, option with IP67 environmental protection
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Housing Ø78, insulated hollow shaft | Ø12, Ø15, Ø20 or Ø25 mm H7 | Insulated elastic coupling | Up to 8192 steps (13 bits) | Parallel or SSI | 5, 15, 8–24, 18–28 or 10–30 V | IP65 shaft (IP66 sealed)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Incremental (with pinion encoder) | Pre-assembled for 12 encoders | Stroke 100 to 50,000 mm | Resolution 1 µm to 1 mm | Modules 1, 0.796 and 0.815 | C10 steel support | Optional laser certification (S/N)
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø4, Ø6, Ø8 or Ø10 h7 | Housing Ø56 mm | 1 to 1024 imp/rev | NPN, push-pull or line driver | Power supply 5–30 V | IP53 shaft side | Built-in coupling · 60 kHz
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Metal housing Ø102 mm | Shaft Ø12 h7 stainless steel | 1 to 25000 imp/rev | NPN, PNP, push-pull, 1 Vpp | Power supply 5–30 V | IP65 shaft (IP66 sealed) | 100 kHz (300 kHz optional)
DPF Sensors logo
Precision pressure transducer
Shopping Basket