TM1 magnetostrictive transducer with SAE J1939 threaded flange

Budget-friendly price Request a quote
Magnetostrictive, non-contact | CAN SAE J1939 | Stroke 50 … 2000 mm | Linearity ≤ ±0.04 % FS (min. 300 µm) | Resolution ≤ 0.1 mm | 12/24 VDC (8 … 34 VDC) | 350 bar · IP67

Novotechnik TM1 transducer with SAE J1939 threaded flange. NOVOSTRICTIVE technology, non-contact.

Absolute linear magnetostrictive transducer with stainless steel flange welded to the rod. Stroke from 50 to 2000 mm. Working pressure up to 350 bar. Passive annular position marker. Industrial and mobile application versions.

Key points

  • Working pressure up to 350 bar, peak pressure up to 450 bar
  • Unlimited mechanical life
  • No speed limit for the position marker
  • Absolute exit

Technical Frequently Asked Questions

What can be connected to the TM1 transducer with SAE J1939 threaded flange?

It can be connected to Novotechnik M12 connectors and cables and Novotechnik linear sensor positioners (magnets and cursors).

How do I order the TM1 transducer with SAE J1939 threaded flange?

The order code has six fields: stroke (mm), mechanical version, interface, parameters, speed, and connection. For example, TM1-0500-306-J14-106 is the version with a 500 mm electrical range, M18x1.5 threaded flange, CAN SAE J1939, 1x position and 1x speed, 250 kBaud, and a 5-pin M12x1 connector. All the options for each field are available in the order code configurator on this page.

Under what conditions does the TM1 transducer with SAE J1939 threaded flange operate?

Operating temperature: -40 … +105 °C. Protection: IP67.

Properties

FeatureSpecification
Description
FlangeStainless steel 1.4307 / AISI 304L
Flange coverAlSiMgBi
RodStainless steel 1.4571 / AISI 316Ti
WatertightnessNBR 90 SH A O-ring
Assembly, IndustrialScrewed in using M18x1.5 thread
Assembly, Mobile ApplicationsScrewed into the cylinder using an M18x1.5 socket for threaded plug hole according to ISO 6149
Electrical connection, IndustrialM12x1 connector, A encoding
Electrical connection, Mobile applicationsM12x1 connector, A encoding
Electrical data
Measured variablesPosition, speed, and temperature
Electrical range (L dimension)0 … 50 mm up to 0 … 2000 mm
Speed measurement range25 … 1000 mm/s
ProtocolCAN SAE J1939
Programmable parametersPosition offset, averaged, transmission speed, transmission mode, transmission cycle, origin direction
Address (Node ID)128 … 247 (dynamic address assignment)
Transmission speed250, 500 kBaud
Update frequency (output)1 kHz (internal measurement frequency 0.5 kHz)
Absolute linearity≤ ±0.04 % FS (min. 300 µm)
Electrical zero point tolerance±1 mm
Position resolution≤ 0.1 mm
Speed resolution2 mm/s
Repeatability≤ ±0.1 mm
Hysteresis≤ ±0.1 mm
Temperature error≤ ±15 ppm/K (min. 0.01 mm/K)
Supply voltage Ub12/24 VDC (8 … 34 VDC)
Power supply voltage ripple≤ 10 % Ub
No-load consumption< 1.5 W
Overvoltage protection40 VDC (6 s)
Reverse polarity protectionYes (power lines and outlets)
Short circuit protectionYes (all outputs connected to GND and the supply voltage)
Insulation resistance (500 VDC)≥ 10 MΩ
Internal bus terminationNo (120 Ω internal load resistance, on request)
Environmental conditions
Maximum working speedMechanically unlimited
Vibration IEC 60068-2-620 g, 10 … 2000 Hz, Amax = 0.75 mm
IEC 60068-2-27 Shock100 g, 11 ms (one stroke)
DIN EN 60529 protectionIP67
Working temperature-40 … +105 °C
Working humidity0 … 95 % HR (non-condensing)
Working pressure≤ 350 bar
Pressure spikes≤ 450 bar
Bursting pressure> 700 bar
LifeMechanically unlimited
MTTF (IEC 60050)391 years
TraceabilitySerial number on the label: production batch of the sensor assembly and its components
EMC, Industrial version
EN 61000-4-2 ESD, discharge by contact4 kV
EN 61000-4-2 ESD, air discharge8 kV
EN 61000-4-3 Electromagnetic fields (RFI)10 V/m
EN 61000-4-4 Fast transients (burst)1 kV
EN 61000-4-6 Conducted disturbances (HF fields)10 V ef.
EN 55016-2-3 Radiated disturbancesIndustrial and residential area
Connection assignment
SignConnector, code 106
Supply voltage UbPin 2
GNDPin 3
CAN_HPin 4
CAN_LPin 5
CAN_SHLD, IndustrialPin 1
Unassigned, Mobile ApplicationsPin 1
EMC, Mobile Applications version
ISO 10605 ESD (handling)8 kV
ISO 10605 ESD (component)15 kV
ISO 11452-2 Radiated HF fields100 V/m
ISO 11452-4 BCI (mass current injection)200 mA
CISPR 25 Radiated emissionLevel 4
ISO 7637-2 Transient emissionsLevel 1/2
ISO 7637-2 Pulses on the feed lines (1, 2a, 2b, 3a, 3b)Level 4
ISO 7637-3 Pulses on output lines (3a, 3b)Fast Level 2
ISO 16750 Pulses on power lines, startup profileLevel 4 with 12V; Level 3 with 24V
ISO 16750 Pulses on power lines, Load dump A+200 V
EN 13309 Construction machineryEmission and disturbance resistance: exceeds E1 requirements
ISO 14982 Agricultural and forestry machineryEmission and disturbance resistance: exceeds E1 requirements
OptionMeaning
Example: TM1-0500-306-J14-106 = 500 mm electrical range, M18x1.5 threaded flange, CAN SAE J1939, 1x position and 1x speed, 250 kBaud and 5-pole M12x1 connector.
1. Electrical range (mm)
0050 … 2000Standard, 25 mm increments; other lengths available upon request
2 · Mechanical version
306M18x1.5 threaded flange
308M18x1.5 threaded flange with M4x6 internal thread at the rod end (7.5 mm longer)
3 · Electrical interface
JCAN SAE J1939
4 · Interface parameters
11x position, 1x speed
5 · Transmission speed
3500 kBaud
4250 kBaud
6. Electrical connection
106M12x1 connector, 5 poles
The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference.
Novotechnik TM1 magnetostrictive transducer with SAE J1939 threaded flange
Dimensional drawing CANopen Novotechnik TM1 threaded flange magnetostrictive transducer

Other products

Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
44 mm square flange | Shaft Ø6 h7, centered Ø20 h7 | 1–2540 imp/rev | NPN, PNP, push-pull, driver, TTL | 5–30 V | IP66 shaft (IP53 under torque) | 60 kHz (100 kHz optional)
LVDT Manufacturer Logo Schreiber Messtechnik
LVDT inductive sensor | Strokes 5–20 mm depending on version | M12×1 threaded housing | Linearity 0.25 % / 0.5 % | IP66/IP67 | Moving core or spring-loaded probe | External electronics
DPF Sensors logo
Ultrasonic level sensor, range up to 10 meters, RS485/4-20 mA/0-5 Vdc output signal.
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Incremental A/B/Z, RS-422 (TTL) or HTL | Ø 28 mm | 1024 ppr (4096 counts) | Shaft Ø 6 mm or push-in coupling | 5 VDC or 24 VDC | IP54 / IP65 / IP67
B&C Electronics – Italian manufacturer of industrial water sensors and analyzers
Black platinum electrodes, K=1cm-1 (2 to 2,000mS) Diameter 12 and 110 lake, body material PVidrio and epoxy, temperature, up to 70ºC, BNC connector with 1.5m long cable
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø10, 12, 14, 15 or 20 mm | Housing Ø72 mm | 1 to 25000 imp/revolution | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP64 shaft (IP66 Z-seal) | Compensation ±3 mm axial, ±2°
Monitran-Logo
Output 10-100mV/g | Frequency 2Hz-8kHz | Negative Power Supply -24VDC | Temperature -55 to 140°C | IP67 Protection | Stainless Steel | Isolated AC Output | Isolated Base | 3-Wire Connection | Top Entry Mounting
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Absolute, thread Ø 0.9 mm | Race up to 3 m | Resolution 0.1 or 1 mm | CANopen or CAN fiber optic | 10–30 V DC | IP64 (IP65 cable gland) | Linearity ±0.05 % fs.
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Servo flange Ø41.5 mm, shaft Ø6.35 h7 | 8192 steps/revolution (13 bits) | SSI (RS422), natural binary | Power supply 5 V, 5–30 or 10–30 V | IP64 shaft (IP66 sealed) | 12000 rpm with low torque (option B) | Impacts 100 G (6 ms)
Shopping Basket