MCS Signal Conditioning Module

Budget-friendly price Request a quote
Single-channel | Inputs: Pt100, thermopile, voltage, current, frequency | Outputs: 0-2Vdc, 0-20mA, 4-20mA, RS485, Modbus | 18-bit | 10-30Vdc

The NESA MCS is a single-channel module for conditioning digital and analog electrical signals. It accepts Pt100 signals, thermopiles, voltages up to 2Vdc (or micro-voltages, e.g., 0-100mV), currents 0-20mA or 4-20mA, frequencies up to 1000Hz, and pulse counts (min. 1ms) as inputs, and generates a standardized signal in 0-2Vdc voltage, 0-20mA or 4-20mA current, RS485 digital format, or Modbus over RS485.

It converts 18 bits (over 262,000 points) onto a differential input with <2µV accuracy across the entire scale. It operates on 10–30Vdc, typically consumes 4mA @ 12Vdc, and functions from -40°C to +80°C. This 2-unit DIN rail module complies with CE standards. It is programmable via a USB-MCS-I interface.

Key points

  • Inputs: Pt100, thermopiles, voltages up to 2Vdc, currents 0÷20mA or 4÷20mA, frequency up to 1000Hz and pulse count (min. 1ms)
  • Outputs: 0-2Vdc, 0-20mA, 4-20mA, RS485 and Modbus over RS485
  • 18-bit resolution with over 262,000 points; accuracy <2µV across the entire scale
  • Power supply 10÷30Vdc; typical consumption 4mA@12Vdc; -40°C÷+80°C
  • Any input can be associated with any output, with zero and offset regulation
  • DIN rail module, 2 units; compliant with CE standards

Technical Frequently Asked Questions

What signals does it accept at input?

Pt100, thermopiles, voltages up to 2Vdc (or micro voltages, e.g. 0÷100mV), currents 0÷20mA or 4÷20mA, frequency up to 1000Hz and pulse count (min. 1ms).

What options does it offer?

Voltage 0÷2Vdc, current 0÷20mA or 4÷20mA, RS485 (via command line) and Modbus over RS485. The RS485 is not isolated.

What is its resolution and accuracy?

18-bit resolution with over 262,000 points; accuracy <2µV across the entire scale.

Properties

FeatureSpecification
Inputs and accuracy
Product typeSingle-channel module for conditioning digital and analog electrical signals
Differential inputWith current generator for Pt100
Temperature inputPt100, thermopiles
Power inputVoltages up to 2Vdc (micro voltages, e.g. 0÷100mV)
Power input0÷20mA or 4÷20mA
Frequency inputUp to 1000Hz
Pulse countMin. 1ms
Resolution18-bit with more than 262,000 points
Accuracy<2µV across the entire scale
Departures
Voltage output0÷2Vdc
Current output0÷20mA or 4÷20mA
Digital outputRS485 (via command line)
Modbus outputModbus over RS485
Real-time readingWith digital output, input signal values are sent directly to the RS485 line (not isolated)
Functions and programming
ProgrammingUSB-MCS-I Interface
SelectionInputs on different scales and outputs, with the possibility of associating different measurement scale ranges
RegulationZero and offset
Input-output associationOnce the electrical range and the type (analog or digital) of the input are defined, a standard output is chosen and a specific measurement range is associated with it.
ExamplePt100 signals with different ranges (e.g. -40°C to +60°C and 0 to +80°C) associated with the same output (e.g. 0 to 2Vdc), or the same input signal with different outputs
«Analog» counting systems»Automatic reset when the imposed bottom-of-scale value is exceeded
SupplyCalibrated with extremely high precision systems and programmed according to the customer's specifications
Power supply, environment, and mechanical data
Feeding10÷30Vdc
ConsumptionTypical 4mA@12Vdc
Operating temperature-40°C to +80°C
ContainerModule for DIN rail, 2 units
AccordanceEC
ReferenceConfiguration
MCSMCSDescription: DIN rail module, pre-programmed for the conversion of input signals: Pt100, thermopile, voltages (micro-voltages 0-100mV) and currents or digital signals (frequency or count), and output signals: 0-2Vdc, 0-20mA, 4-20mA, RS485, Modbus RTU RS485. The selected input and output types are indicated.
NESA MCS Signal Conditioning Module

Other products

Dimetix_AG-1
Precision Mechanical Support for Laser Aiming Range: Mechanical adjustment of +/- 4° on two axes for stable readings at long distances
Modular recorder
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Output 0…10 V, 0…20 mA or 4…20 mA | For LWH and TLH | 18…30 VDC | Typical linearity 0.01 % | IP 65 | Cable Ø 4…10 mm
DPF Sensors logo
RTD duplicator-isolator to 4/20mA (Active/Passive) and 0-10 Vdc
DPF Sensors logo
2-position meter for potentiometer (displacement unit to be specified) Valid for any potentiometer value 2 selectable scales (factory) Powered by batteries and charger, LCD display
NESA Environmental Meters
Frecuencia, 0÷2Vdc, 4÷20mA, RS485 | 0,28 ÷ 50 m/s | Primera clase (First Class) IEC 61400-12-1 | R 125 mm · 300 mm | 10 ÷ 28Vdc | Conector IP68
DPF Sensors logo
Regulator for electromagnetic vibrators 2, 3, 10 Amp
DPF Sensors logo
Wirelessly configurable RTD to 4/20mA converter (Active/Passive)
Dimetix_AG-1
Advanced High-Speed, High-Performance Industrial Communication Solution Range: Native IP65 integration with 10/100 Mbit/s transfer
Shopping Basket