Signal conditioner for LWH and TLH MUW 200/250

Budget-friendly price Request a quote
Output 0…10 V, 0…20 mA or 4…20 mA | For LWH and TLH | 18…30 VDC | Typical linearity 0.01 % | IP 65 | Cable Ø 4…10 mm

Novotechnik MUW 200/250 signal conditioner. Interface module on DIN connector 43650.

Interface module for LWH and TLH series position transducers, in a DIN 43650 connector enclosure. Input > 10 MΩ; standard output 0…10 V, 0…20 mA or 4…20 mA. Typical linearity 0.01%, typical temperature coefficient 30 ppm/K, IP 65. 200 series: fixed range and zero point; 250 series: adjustable with spindle trimmers.

Key points

  • Interface module for TLH and LWH series position transducers
  • Standardized output signals: 0…10 V, 0…20 mA and 4…20 mA
  • Typical linearity 0.01%

Technical Frequently Asked Questions

How do I order the MUW 200/250 signal conditioner?

For example, MUW-250-1 (Art. 400054152) is the 250 series version, with adjustable range and zero point, and 0…10 V output. All order references with their Art. are listed in the reference table on this page.

Under what conditions does the MUW 200/250 signal conditioner operate?

Operating temperature: -25…+70 °C. Protection: IP 65 (DIN 400 50 / IEC 529).

Properties

FeatureSpecification
What does it measure?
Supported transducersLWH and TLH Series
Input resistance> 10 MΩ
Cursor signal captureNo load
Permissible connection resistance of the transducer≥ 700 Ω
How to measure
Internal reference voltage for the transducer> 10 V DC, short circuit proof
Linearity0.01% (typical)
Temperature coefficient*30 ppm/K (typical)
Zero point adjustment range (250 series)10 %
Gain adjustment range (250 series)1…2
What delivers
ExitCharge or current
0…20 mAMaximum load impedance 500 Ω
0…10 VI max. 20 mA, short circuit proof
4…20 mAMaximum load impedance 500 Ω
Functions
200 SeriesNon-adjustable range and zero point
250 SeriesAdjustable range and zero point with spindle trimmers
Direction of exitIt rises when moving the rod (LWH) or the cursor (TLH) from terminal 1 to 3 (supply state)
Reversal of directionSwapping terminals 1 (black) and 3 (blue) on the insert
Connection cable orientationIn 90° steps, rotating the box insert
Special configurationsWith other supply voltages, output voltages or adjustment ranges, available upon request
Food and environment
Supply voltage18…30 VDC
Current consumptionmax. 35 mA
Reverse polarity protectionIntegrated
Working temperature-25…+70 °C
ProtectionIP 65 (DIN 400 50 / IEC 529)
Mechanical data
DimensionsView map
Connection terminalsScrew type, 0.5 mm²
Recommended cable3 or 4 braided wires with protective mesh, Ø 4…10 mm
Cable entryRacor PG 11
Weightapprox. 75 g
Included in the supply1 M3x40 center screw and 1 flat gasket
Accordance
EU: Electromagnetic compatibilityDirective 2014/30/EU: EN 61326-1:2013, EN 61326-2-3:2013
EU: RoHSDirectives 2011/65/EU and 2015/863/EU: EN IEC 63000:2018
United Kingdom: Electromagnetic compatibilitySI 2016/1091: EN 61326-1:2013, EN 61326-2-3:2013
United Kingdom: RoHSSI 2012/3032 and SI 2020/1647: EN IEC 63000:2018
ReferenceConfiguration
MUW-200-0MUW2000Art. 400054101 · Type and output: 200 Series, fixed, 0…20 mA
MUW-200-1MUW2001Art. 400054102 · Type and output: 200 Series, fixed, 0…10 V
MUW-200-4MUW2004Art. 400054103 · Type and output: 200 Series, fixed, 4…20 mA
MUW-250-0MUW2500Art. 400054151 · Type and output: 250 Series, adjustable, 0…20 mA
MUW-250-1MUW2501Art. 400054152 · Type and output: 250 Series, adjustable, 0…10 V
MUW-250-4MUW2504Art. 400054153 · Type and output: 250 Series, adjustable, 4…20 mA
Novotechnik MUW 200/250 Signal Conditioner for LWH and TLH
Dimensional drawing Signal conditioner for LWH and TLH MUW 200/250 Novotechnik

Other products

Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
Magnetostrictive | IO-Link V1.1, COM 3 | Stroke 50 … 4250 mm | Resolution 1 or 5 µm | 1 to 3 position markers | 18 … 30 VDC | 350 bar · IP67 / IP68
Dimetix_AG-1
Camisa de refrigeración por aire (Air-cooling Jacket) | Refrigeración forzada continua con aire comprimido | Para sensores láser Dimetix D-Series | Entornos de alta temperatura: acerías y fundiciones
DPF Sensors logo
2-way universal galvanic isolator/converter. 2 channels, Input: 4/20 mA (Active/Passive), Output: 0-10 VDC, Power supply: 10-30 VDC
DPF Sensors logo
Process indicator, 32 x 74 format, LARGE FORMAT display, Pt100 input – Thermocouple – mA – Vcc – potentiometer
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
CANopen | Ø 36 mm | 16 bits per revolution | Shaft Ø 6 mm, Ø 10 mm or hollow Ø 6 mm | 12/24 VDC (8 … 32 VDC) | IP67 / IP69K | Measuring range: 44 revolutions (15840°)
DPF Sensors logo
Isolated multiplexer of 8 Pt100 probes, obtaining double output (0-4/20mA and 0/10V)
DPF Sensors logo
Thermocouple converter and Pt100, Pt500, Pt1000, Ni100. 2, 3 or 4 wires, programmable via PC
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
IO-Link | Ø 22 mm | 16 bits per revolution | Shaft Ø 6 mm | 24 VDC (16 … 30 VDC) | IP50 / IP65 | Measuring range: 44 revolutions (15840°)
Official logo of Novotechnik, manufacturer of linear sensors, position transducers, and industrial encoders
-40 … +105 °C (Z-TH1) | Pressure ≤ 40 bar (Z-TH1-P32) | Stem Ø 10 mm and profile
Shopping Basket