TH1 magnetostrictive rod pulse transducer
- Manufacturer: Novotechnik
- Category: Displacement, SENSORS, Magnetostrictive Linear Transducer, Linear Transducers
Novotechnik TH1 magnetostrictive pulse transducer. NOVOSTRICTIVE technology, contactless.
Magnetostrictive rod transducer for non-contact linear position measurement. Stroke from 50 to 4250 mm. Working pressure up to 350 bar. Passive annular position marker. Depending on the interface, it measures up to three positions and speed.
Key points
- Position detection with ring placeholder
- Unlimited mechanical life
- Resolution down to 1 µm, independent of length
- Temperature coefficient ≤ 15 ppm/K
Technical Frequently Asked Questions
What can be connected to the TH1 pulse magnetostrictive transducer?
It can be connected to Novotechnik M12 connectors and cables, Novotechnik M16 connectors and cables, and Novotechnik linear sensor positioners (magnets and cursors).
How do I order the TH1 pulse magnetostrictive transducer?
The order code has 6 fields: stroke (mm), mechanical version, interface, signal, markers, and connection. For example, TH1-0800-102-111-102 is the version with an 800 mm electrical range, M18x1.5 threaded flange with a 30 mm zero point, Start/Stop pulse interface for 1 position marker, and an 8-pin M12x1 connector. All the options for each field are available in the order code configurator on this page.
Under what conditions does the TH1 pulse magnetostrictive transducer operate?
Operating temperature: -40 … +85 °C. Protection: IP67.
Properties
| Feature | Specification |
|---|---|
| Description | |
| Housing | Anodized aluminum AlMgSi0.5 F22, 3.3206.71 |
| Threaded flange | Stainless steel X2CrNiMoN 18-14-3, 1.3952 |
| Rod | Stainless steel X6CrNiMoTi 17-12-2, 1.4571 |
| Mounting | M18x1.5 bushing for threaded plug drill according to ISO 6149; 3/4"-16UNF bushing for threaded plug drill according to SAE J475 |
| Placeholder | Ring placeholder |
| Measurement principle | NOVOSTRICTIVE, non-contact magnetostrictive |
| Electrical connection | M12x1 connector with 4, 5 or 8 poles, shielded; M16x0.75 (IEC 130-9) connector with 6 or 8 poles, shielded; 8x 0.25 mm² PUR cable, shielded, 1, 3 or 5 m |
| Electronics | SMD with integrated ASIC; the connector housing (display) is bonded to the sensor housing; the housing is capacitively decoupled from the electronics |
| Mechanical data | |
| Electrical range (L dimension) | 0050 … 4250 mm in 25 mm increments; other lengths available upon request |
| Maximum operating speed with valid output signal | 10 m/s |
| Maximum operating acceleration with valid output signal | 200 m/s² |
| IEC 60068-2-27 Shock | 100 g (11 ms), one stroke |
| Vibration IEC 60068-2-6 | 20 g (5 … 2000 Hz, Amax = 0.75 mm) |
| DIN EN 60529 protection, with fixed connector | IP67 |
| DIN EN 60529 protection, with cable | IP68 |
| Life | Mechanically unlimited |
| Working temperature | -40 … +85 °C |
| Storage temperature | -40 … +100 °C |
| Working humidity | 0 … 95 % HR (non-condensing) |
| Working pressure | ≤ 350 bar |
| Pressure spikes | ≤ 600 bar |
| Bursting pressure | > 700 bar |
| Electrical data | |
| Electrical range (L dimension) | 0050 … 4250 mm |
| Number of placeholders | 1 to 3 |
| Protocol | Impulses |
| Tickets | RS422 |
| Sampling frequency (update) | < 500mm: 1kHz; 500 … < 2000 mm: 0.5 kHz; > 2000mm: 0.25kHz |
| Resolution | According to the interpretation, normalized to 2800 m/s |
| Absolute linearity, < 1000 mm | ≤ ±50 µm |
| Absolute linearity, < 2500 mm | ≤ ±80 µm |
| Absolute linearity, up to 4250 mm | ≤ ±120 µm |
| Electrical zero point tolerance | ±0.5 mm |
| Reproducibility | ≤ 6 µm |
| Hysteresis | ≤ 4 µm |
| Temperature error | ≤ 15 ppm/K (min. 0.01 mm/K) |
| Supply voltage | 24 (13 … 34) VDC |
| Power supply voltage ripple | ≤ 10 % Ub |
| Overvoltage protection | 40 VDC (permanent) |
| Current consumption | ≤ 100 mA |
| Reverse polarity protection | Yes, up to the maximum supply voltage. |
| Short circuit protection | Yes (outputs to GND and supply voltage up to 7V) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Safety and compliance | |
| MTTF (IEC 60050) | 347 years |
| Accordance | EC |
| Electromagnetic compatibility | |
| EN 61000-4-2 | Electrostatic discharges (ESD) 4 kV, 8 kV |
| EN 61000-4-3 | Electromagnetic fields 10 V/m |
| EN 61000-4-4 | Fast transients (burst) 2 kV |
| EN 61000-4-6 | Conducted disturbances induced by RF fields 10 V rms. |
| EN 55011 | Radiated disturbances, class B |
| Option | Meaning |
|---|---|
| Example: TH1-0800-102-111-102 = 800 mm electrical range, M18x1.5 threaded flange with zero point at 30 mm, Start/Stop pulse interface for 1 position marker and 8-pole M12x1 connector. | |
| 1. Electrical range (mm) | |
| 0050 … 4250 | Standard, 25 mm increments; other lengths available upon request |
| 2 · Mechanical version | |
| 102 | M18x1.5 threaded flange, zero point at 30 mm |
| 103 | 3/4"-16UNF threaded flange, zero point at 30 mm |
| 104 | M18x1.5 threaded flange, zero point at 51 mm |
| 105 | 3/4"-16UNF threaded flange, zero point at 51 mm |
| 106 | M18x1.5, zero point at 30 mm, with end support (*) |
| 107 | 3/4"-16UNF, zero point at 30 mm, with end support (*) |
| 108 | M18x1.5, zero point at 51 mm, with end support (*) |
| 109 | 3/4"-16UNF, zero point at 51 mm, with end support (*) |
| 3 · Electrical interface | |
| 1 | Pulse interface |
| 4 · Output signal (1__) | |
| 1 | Pulse interface, Start/Stop signal |
| 5 · Placeholders (11_) | |
| 1 | For 1 placeholder |
| 2 | For 2 markers (from 150 mm measuring length) |
| 3 | For 3 markers (from 250 mm measuring length) |
| 6. Electrical connection | |
| 101 | Connector M16x0.75 (IEC 130-9), 8 poles |
| 102 | M12x1 connector, 8 poles |
| 103 | Connector M16x0.75 (IEC 130-9), 6 poles |
| 201 | 8-wire cable, shielded, 1 m |
| 203 | 8-wire cable, shielded, 3 m |
| 205 | 8-wire cable, shielded, 5 m |
| The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference. | |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications
Other products