Dimetix DAN-10-150 Laser Distance Sensor

Industrial laser sensor for measuring up to ~100 m directly on natural surfaces and up to 150 m with reflector, with ±1 mm @2σ and up to 100 Hz.

DAN-10-150 it's a Dimetrix D Series industrial laser distance sensor For non-contact measurement. Its range is 0.05…~100 m on natural surfaces and ~40…150 m with reflector. Typical accuracy is ±1.0 mm @2σ (±0.5 mm @1σ), with a maximum frequency of 100 Hz.

The DAN-10-150 covers the intermediate range that many comparisons overlook: up to ~100 m without reflector and 150 m with reflector, maintaining ±1 mm @2σ. It is one of the models with the clearest evidence of application in tunnel monitoring and bridge deflection.

1. What does this model offer and when should you choose it?

The selection should be based on the actual distance, tolerance, target speed, surface, and control system.

  • For monitoring structures, tunnels and civil works when millimeter precision is needed without reaching 500 m.
  • For multipoint networks via RS-485 or industrial Ethernet.
  • For alarm systems where several measurements are averaged and compared to limits.
  • For deflection tests where it is important to measure from the ground without installing a contact transducer on the structure.

Alternatives within the D Series: DAE-10-050 for distances up to 50 m and -40 °C; DEN-10-500 if it is necessary to extend up to 500 m.

2. Engineering applications and examples

The following examples are taken from documented applications using Dimetix technology and have been selected because they help to understand How is distance measurement used to obtain position, level, deformation, or dimension?, not just because they share a keyword.

Deformation monitoring in railway tunnels

Dimetix documented the direct use of the DAN-10-150 on concrete. The sensor measured the distance from a crossbeam or transverse structure to the vault; the position of that structure was monitored separately. The integration used RS-485, and 10 measurements were averaged every 10 minutes. The system generated automatic alerts if limits were exceeded and was designed to operate 24/7 with very restricted access.

Bridge deflection test

In another case, four DAN-10-150 sensors were used under a bridge to measure deflection at predefined points. The sensors were mounted on independent supports on ballast, and it was verified that the passage of trains on an adjacent track did not affect the readings. Deflection curves were recorded in real time during controlled loads and returned to zero when the load was removed.

Railway infrastructure

Laser measurement is also used for clearance, separation from infrastructure elements, and catenary control. The visible beam makes it easy to orient the sensor to the desired geometric point.

Movement of large structures

Multiple sensors can work simultaneously to verify that different points on a bridge or building move the same distance during a controlled maneuver.

3. Integration, installation and practical limitations
  • Interfaces: RS-232, RS-422/RS-485 and SSI; USB for configuration.
  • Analog output: 0/4…20 mA programmable, max. error ±0.1 %.
  • Digital I/O: 2 programmable digital outputs + 1 error output + 1 digital input.
  • Industrial Ethernet: PROFINET, EtherNet/IP and EtherCAT via optional cover.
  • RS-485 can address up to 100 sensors, but the communication configuration and tracking mode must be properly planned for multipoint networks.
  • The sensor has moving average filters and peak/error suppression, useful in monitoring; filtering improves stability at the cost of time response.
  • On concrete, stone, or rough surfaces, it's best to aim at a representative and stable area. The laser spot's geometry increases with distance.
  • For 100…150 m with reflector, confirm that the dot remains completely within the plate throughout the movement.

In critical applications, it is advisable to validate the target surface, ambient light, geometry, optical contamination, speed, and atmosphere before setting the final usable range.

Selection and integration with GUEMISA
We can check actual distance, surface, reflector, accuracy, frequency, 4-20 mA output, RS-485/SSI or industrial Ethernet to define the appropriate configuration of the DAN-10-150.

Properties

DIMETIX DAN-10-150 TECHNICAL SPECIFICATIONS
Model / Item No.DAN-10-150 / 500632
Range on natural surfaces0.05…~100 m
Range with reflector~40…150 m
Typical accuracy @2σ / @1σ±1.0 mm / ±0.5 mm
Typical repeatability @2σ / @1σ±0.3 mm / ±0.15 mm
Maximum measurement frequency100 Hz
Maximum output frequency100 Hz
Operating temperature-10…+50 °C
Food / consumption12…30 VDC / 0.15 A @ 24 VDC
Analog output0/4…20 mA programmable, max. error ±0.1 %
Serial interfacesRS-232, RS-422/RS-485 and SSI; USB for configuration
Digital I/O2 programmable digital outputs + 1 error output + 1 digital input
Optional Industrial EthernetPROFINET, EtherNet/IP and EtherCAT via optional cover
LaserRed visible, Class 2
Typical laser spot diameter7 × 3mm @10m; 28 × 13mm @50m; 55 × 30mm @100m
ProtectionIP65
Mechanical testsShock IEC 60068-2-27; vibration IEC 60068-2-6
Dimensions140 × 78 × 48 mm
Weight350 g
LDS-8H_HP-1
Laser sensor technical diagram

Other products

Pesacam logo: Weighing systems for trucks
Wireless cabin | Smartphone App Connection | 3 High-Precision Sensors | Bellvei Headquarters
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Ø59 mm, hollow shaft Ø15 H7 | Up to 2²⁴ steps in 4096 turns | Gray or binary | Parallel NPN 70 mA or SSI RS422 | Power supply 5 ±5 %, 8–24 or 18–28 V | IP64 shaft (IP65 sealed) | Tangential anti-rotation pin
B&C ELECTRONICS Logo 2026 WATER QUALITY
Industrial pH electrode with integrated Pt100, double PTFE junction, PVDF body and 4-pin connector. 0–12 pH.
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Brida cuadrada 44×44, eje Ø6 h7 | 8 a 2048 imp/giro | Line driver 26LS31/ET7272, NPN | Alim. 5, 8–24, 18–28, 10–30, 5–30 V | IP66 eje (IP53 con bajo par) | 12000 rpm con bajo par (opción B) | Impactos 100 G (6 ms)
LOGO TORQUE CERTIFICATION
Digital PCM Transmission | 30,000 – 50,000 N·m | 10,000 RPM | PCD Flange 290.0 mm | Inertia 0.5695 kg·m²
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Low profile Ø68 mm | Servo clamp mounting | Ø6 h7 stainless steel shaft | 1 to 10000 pulses/revolution | NPN, PNP, push-pull, driver, TTL | 5–30 V power supply | IP64 shaft, IP66 seal
Monitran-Logo
Dual Output | 4-20mA + AC Output | Configurable Speed Range | 2Hz-1kHz Frequency | 12-32V DC Power Supply | -25 to 90°C Temperature | IP67 Protection | Stainless Steel | Insulated Base | 3-pin Connector | 62GB
Wire displacement sensor, ranges from 100 mm to 1250 mm, with 5 Kohm resistance output signal, 0-5/10 Vdc, 4-20 mA, RS485 or pulse, optionally with IP67 environmental protection. Robust
Official logo of ELCIS Encoder, Italian manufacturer of incremental and absolute encoders and industrial measurement systems.
Hollow shaft Ø6–15 mm | Housing Ø59 mm | 1 to 25000 imp/rev | NPN, PNP, push-pull, driver, 1 Vpp | Power supply 5–30 V | IP65 shaft (IP66 Z-seal) | Tangential coupling
Shopping Basket