IEPE: isolated AC output 100 mV/g ±10% | 2Hz to 10kHz ±5% | Base mounted resonance 18 kHz | Ex ia IIC T4/T6 Ga · Ex ia IIIC T135/T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | Constant current 0.5 to 8 mA, 12 V DC | Stainless steel, IP67 (IW and ISW: IP68)

The Monitran MTN/1100 is an industrial constant current accelerometer (IEPE) with isolated AC output, standard sensitivity of 100 mV/g ±10% at 80 Hz, and a frequency response of 2 Hz to 10 kHz ±5% (−3 dB at 0.8 Hz). It is ATEX and IECEx Group II intrinsically safe (Ex ia IIC T4/T6 Ga) for use in gas environments; the 1100I, 1100IW, and 1100ISW variants also include Ex ia IIIC Da dust protection.

Stainless steel body with insulated base, IP67 (1100IW and 1100ISW: IP68, submersible up to 5 m). Five variants: top entry (1100I with 2-pin MS connector, 1100IW with polyurethane cable) and side entry (1100IS with 2-pin MS connector, 1100ISC with ETFE cable with stainless steel overbraid, 1100ISW with polyurethane cable). Guemisa is an official distributor of Monitran in Spain.

Key points

  • Standard sensitivity 100 mV/g ±10% at 80 Hz; optional from 10 to 500 mV/g depending on variant
  • Frequency response 2 Hz to 10 kHz ±5%; mounted base resonance 18 kHz; electrical noise 0.1 mg max.
  • Constant current 0.5 to 8 mA, bias 12 V DC; 500 V insulation test
Ex

BAS02ATEX1057XIECEx BAS 08.0013X

Group II Ambient temperature −55 °C ≤ Ta ≤ +115 °C for T4 and −55 °C ≤ Ta ≤ +65 °C for T6 (1100IW and 1100ISW: T6 only, up to +65 °C)

Intrinsically safe for gas (zones 0, 1, and 2) and, in variants 1100I, 1100IW, and 1100ISW, for dust (zones 20, 21, and 22). Hover or click on each part of the marking to see what it means.

  • Zone 0
  • Zone 1
  • Zone 2
  • Zone 20
  • Zone 21
  • Zone 22

Technical Frequently Asked Questions

In what areas can the Monitran MTN/1100 be installed?

The 1100I, 1100IW, and 1100ISW are marked for gas Ex ia IIC (T4/T6 Ga; IW and ISW T6 only) and dust Ex ia IIIC Da, making them suitable for zones 0, 1, and 2 with gas and zones 20, 21, and 22 with dust. The 1100IS and 1100ISC are marked Ex II 1GD T135 °C Ex ia IIC T4 / T85 °C Ex ia IIC T6 and their blades do not include a dust line. Ambient temperature: −55 °C to +115 °C with T4 and −55 °C to +65 °C with T6 (IW and ISW: up to +65 °C). Certified BAS02ATEX1057X and IECEx BAS 08.0013X, Group II.

Do you need an intrinsically safe barrier?

Yes. The datasheets cite the MTL7728+ (BAS01ATEX7217) or the P&F Z728 (BAS01ATEX7005), or any other barrier conforming to note 5 of drawing ATX027 (1100I, 1100IS and 1100ISC) or drawing ATX028 (1100IW; 1100ISW: note 6). Sensor entity parameters: Ui = 28 V, Ii = 93 mA, Pi = 0.65 W; Ci and Li, as per certificate.

Is it suitable for mining?

No. The MTN/1100 ATEX is certified for Group II (surface industry), not for Group I (methane mines).

Properties

FeatureSpecification
Measure and signal
Measured magnitudeVibration acceleration
ExitIsolated AC (mV), constant current accelerometer (IEPE)
SensitivityStandard 100 mV/g ±10% nominal at 80 Hz. Optional (xx): 10, 30, 50, 100 or 500 mV/g (1100I); 10, 25, 30 or 50 mV/g ±10% (1100IS, 1100ISC and 1100ISW); 10, 25, 30 or 500 mV/g (1100IW)
Frequency response2 Hz to 10 kHz ±5% (−3 dB at 0.8 Hz)
Resonance of the mounted base18 kHz (nominal)
Cross-sectional sensitivityLess than 5%
Electrical noise0.1 mg max.
ATEX/IECEx Certification
ClusterII
Marking (gas)Ex ia IIC T4 Ga and Ex ia IIC T6 Ga (1100I; 1100IS and 1100ISC: Ex II 1GD T135 °C Ex ia IIC T4 and Ex II 1GD T85 °C Ex ia IIC T6, without Ga); Ex ia IIC T6 Ga (1100IW and 1100ISW)
Marking (powder)Ex ia IIIC T135 °C Da and Ex ia IIIC T85 °C Da (1100I); Ex ia IIIC T85 °C Da (1100IW and 1100ISW); the 1100IS and 1100ISC sheets do not indicate dust marking
CertificatesBAS02ATEX1057X and IECEx BAS 08.0013X
Ambient temperatureT4: −55 °C ≤ Ta ≤ +115 °C; T6: −55 °C ≤ Ta ≤ +65 °C (1100IW and 1100ISW: −55 °C ≤ Ta ≤ +65 °C)
Entity parametersUi = 28 V, Ii = 93 mA, Pi = 0.65 W; Ci and Li: see certificate
Barrier1 x MTL7728+ (BAS01ATEX7217) or P&F Z728 (BAS01ATEX7005), or any other barrier that meets note 5 of the ATX027 drawing (1100I, 1100IS and 1100ISC) or of the ATX028 drawing (1100IW; in the 1100ISW it is note 6 of ATX028)
Food and environment
Power supply current0.5 to 8 mA (constant current)
Polarization voltage12 V DC (nominal)
IsolationIsolated base
Insulation testIt passes a 500V insulation test
ProtectionIP67; 1100IW and 1100ISW: IP68, submersible up to 5 m max. (0.5 bar)
Mechanics and connection
Housing materialStainless steel
EntranceTop (1100I and 1100IW) or side (1100IS, 1100ISC and 1100ISW)
Mounting (top entry)¼" UNF female thread or Q/F female quick-release base
Mounting (side entry)Bolt ¼"-28 UNF × 33 mm, M6 × 35 mm or M8 × 28 mm
Dimensions 1100I51.0 mm high, Ø22.0 mm, 25 mm hexagon between faces
Dimensions 1100IW67.0 mm high, Ø22.2 mm, 25 mm hexagon between faces
Tightening torque8 Nm
Weight100g (1100I), 140g (1100IS), 160g (1100ISC), 150g (1100IW), 200g (1100ISW), nominal
Connection 1100I and 1100IS2-pin MS connector (C5015, military style)
Connection 1100ISCIntegral ETFE cable with stainless steel overbraid
1100IW and 1100ISW connectionHeavy-duty integral polyurethane cable with additional PTFE sheath (length to be specified in the order)
Maximum cable lengthSee ATX027 (1100I, 1100IS and 1100ISC) or ATX028 (1100IW and 1100ISW) system drawing
ReferenceConfiguration
MTN/1100I-xx MTN1100IXXVariant: 1100I · Top Input · Connection: 2-pin MS connector (C5015, military style) · Mounting: ¼" UNF female · xx = optional sensitivity in mV/g: 10, 30, 50, 100 or 500 MTN/1100I technical data sheet (PDF)
MTN/1100IQ-xx MTN1100IQXXVariant: 1100I · Top input · Connection: 2-pin MS connector (C5015, military style) · Mounting: Female Q/F quick-release base · xx = optional sensitivity in mV/g: 10, 30, 50, 100 or 500 MTN/1100I technical data sheet (PDF)
MTN/1100IS-xx MTN1100ISXXVariant: 1100IS · Side Entry · Connection: 2-pin MS connector (C5015, military style) · Mounting: ¼"-28 UNF × 33 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100IS technical sheet (PDF)
MTN/1100ISC-xx MTN1100ISCXXVariant: 1100ISC · Side entry · Connection: Integral ETFE cable with stainless steel overbraid · Mounting: ¼"-28 UNF × 33 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISC data sheet (PDF)
MTN/1100ISCM6-xx MTN1100ISCM6XXVariant: 1100ISC · Side entry · Connection: Integral ETFE cable with stainless steel overbraid · Mounting: M6 × 35 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISC data sheet (PDF)
MTN/1100ISCM8-xx MTN1100ISCM8XXVariant: 1100ISC · Side entry · Connection: Integral ETFE cable with stainless steel overbraid · Mounting: M8 × 28 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISC data sheet (PDF)
MTN/1100ISM6-xx MTN1100ISM6XXVariant: 1100IS · Side entry · Connection: 2-pin MS connector (C5015, military style) · Mounting: M6 × 35 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100IS technical sheet (PDF)
MTN/1100ISM8-xx MTN1100ISM8XXVariant: 1100IS · Side entry · Connection: 2-pin MS connector (C5015, military style) · Mounting: M8 × 28 mm bolt · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100IS technical sheet (PDF)
MTN/1100ISW-xx MTN1100ISWXXVariant: 1100ISW · Side entry · Connection: Heavy-duty integral polyurethane cable, length to be specified on order, with additional PTFE sheath · Mounting: ¼"-28 UNF × 33 mm bolt · Submersible to 5 m (0.5 bar) · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISW data sheet (PDF)
MTN/1100ISWM6-xx MTN1100ISWM6XXVariant: 1100ISW · Side entry · Connection: Heavy-duty integral polyurethane cable, length to be specified on order, with additional PTFE sheath · Mounting: M6 × 35 mm bolt · Submersible to 5 m (0.5 bar) · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISW data sheet (PDF)
MTN/1100ISWM8-xx MTN1100ISWM8XXVariant: 1100ISW · Side entry · Connection: Heavy-duty integral polyurethane cable, length to be specified on order, with additional PTFE sheath · Mounting: M8 × 28 mm bolt · Submersible to 5 m (0.5 bar) · xx = optional sensitivity in mV/g (±10%): 10, 25, 30 or 50 MTN/1100ISW data sheet (PDF)
MTN/1100IW-xx MTN1100IWXXVariant: 1100IW · Top entry · Connection: Heavy-duty integral polyurethane cable, length to be specified on order, with additional PTFE sheath · Mounting: ¼" UNF female · Submersible to 5 m (0.5 bar) · xx = optional sensitivity in mV/g: 10, 25, 30 or 500 MTN/1100IW data sheet (PDF)
MTN/1100IWQ-xx MTN1100IWQXXVariant: 1100IW · Top entry · Connection: Heavy-duty integral polyurethane cable, length to be specified on order, with additional PTFE sheath · Mounting: Female Q/F quick-release base · Submersible to 5 m (0.5 bar) · xx = optional sensitivity in mV/g: 10, 25, 30 or 500 MTN/1100IW data sheet (PDF)

Installation in a hazardous area

Dangerous areaSafe zoneSensorBarrierPLC / DCS4-20 mA

Entity parameters

Ui
28 V
II
93 mA
Pi
0.65 W
Ci and Li
View certificate

Barriers

The sheets cite 1 x MTL7728+ (BAS01ATEX7217) or P&F Z728 (BAS01ATEX7005), or any other barrier that complies with note 5 of drawing ATX027 (1100I, 1100IS and 1100ISC) or drawing ATX028 (1100IW); in 1100ISW they refer to note 6 of ATX028.

It should not be installed in an atmosphere laden with high-speed dust.

Warning from the datasheets regarding Group II: Ci and Li values were previously lower; the installer must take into account the increased internal capacitance and inductance of this appliance.

1100IW and 1100ISW: the cable has an additional PTFE sheath, with a surface resistivity greater than 1 GΩ·m, which poses a risk of electrostatic ignition.

Options cited by the sheets: MH002 (standard) and MH088 (stainless steel) coupling connectors in the connector variants, various cable lengths in the cable variants, and a «dustproof option (Group II only)» which the sheets do not detail further.

The 1100IS and 1100ISC datasheets do not indicate dust marking (only the Ex II 1GD gas lines), and none of the published variant datasheets indicate dynamic range.

Intrinsic safety barrier cited in the technical data sheet

MTL7728+

Eaton Zener Barrier, MTL7700 Series

Cited in the Monitran technical data sheet. Barrier data: Eaton specification sheet.

Strain
28 Vdc
Current
93 mA
Polarity
+
Barrier Installation
Zone 2
Protected circuit
You can enter zone 0
Mounting
DIN rail
Protection
IP20
Operating temperature
-20 °C to 60 °C
Dimensions
105 × 90 × 12.6 mm
Weight
140 g

Technical data sheet (PDF) Request a quote

IEPE Monitran MTN/1100 ATEX Accelerometer (1100I variant, top entry, stainless steel)
Monitran MTN/1100I ATEX accelerometer dimension drawing: 51.0 mm high, Ø22.0 mm, 25 mm hexagon between faces, 2-pin MS connector

Other products

Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67 | Group I (mining)
Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67 | Group I (mining)
Monitran-Logo
Isolated IEPE output, 100 mV/g | 2 Hz to 10 kHz ±5 % | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | Ta −55 to +115 °C | Isolated electronics, stainless steel, IP67 | Group I (mining)
Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, integrated cable, IP67 (IW: IP68)
Monitran-Logo
4-20 mA ∝ rms speed | 0-10 to 0-100 mm/s | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67
Monitran-Logo
4-20 mA ∝ rms speed | 0-10 to 0-100 mm/s | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, integrated cable, IP67 (IW: IP68)
Monitran-Logo
4-20 mA ∝ rms speed | 0-10 to 0-100 mm/s | 2 Hz to 1 kHz ±10 % | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32 V DC | Stainless steel, IP67 | Group I (mining)
Monitran-Logo
IEPE: isolated AC output, 100 mV/g ±10% | 2Hz to 10kHz ±5% | Base mounted resonance 18 kHz | Ex ia IIC, T4/T6 (IW: T6 only) | Ui 28 V · Ii 93 mA · Pi 0.65 W | Constant current 0.5 to 8 mA, 12 V DC | Stainless steel, IP67 (ISW and IW: IP68)
Monitran-Logo
4-20 mA ∝ rms acceleration | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67
Shopping Basket