IEPE ATEX Group I Accelerometer Monitran MTN/M2200

Budget-friendly price Request a quote
Isolated IEPE output, 100 mV/g | 2 Hz to 10 kHz ±5 % | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | Ta −55 to +115 °C | Isolated electronics, stainless steel, IP67 | Group I (mining)

The Monitran MTN/M2200 is a general-purpose constant current accelerometer with an isolated AC output, certified to ATEX and IECEx Group I for intrinsic safety (Ex ia I Ma), with a standard sensitivity of 100 mV/g ±10% at 80 Hz and a response of 2 Hz to 10 kHz ±5%. The datasheets cite applications in general industry, compressors and pumps, oil and petrochemicals, and mining.

Stainless steel body with insulated base and isolated internal electronics to minimize noise and provide greater polarization voltage stability; IP67 rated. Four variants: top entry (M2200I with 2-pin MS connector, M2200IC with integrated ETFE cable) and side entry (M2200IS with connector, M2200ISC with cable) with ¼"-28 UNF, M6, or M8 mounting bolts. Guemisa is an official distributor of Monitran in Spain.

Key points

  • Sensitivity 100 mV/g ±10% at 80 Hz; optional from 10 to 1000 mV/g
  • Frequency response from 2 Hz to 10 kHz ±5% (−3 dB at 0.8 Hz); mounted base resonance 18 kHz
  • Ambient temperature from −55 °C to +115 °C; stainless steel, IP67
Ex

BAS02ATEX0245XIECEx BAS 08.0013X

Group I Ambient temperature −55 °C ≤ Ta ≤ +115 °C

Intrinsically safe for mining (Group I, protection level Ma). Hover or click on each part of the marking to see what it means.

  • Mining (Group I)

Technical Frequently Asked Questions

For what environments is the Monitran MTN/M2200 certified?

For Group I (mining), with Ex ia I Ma marking, ambient temperature from −55 °C to +115 °C and BAS02ATEX0245X and IECEx BAS 08.0013X certificates.

Do you need an intrinsically safe barrier?

Yes. It connects through a barrier. The datasheets cite the MTL7728+ (BAS01ATEX7217) and the P&F Z728 (BAS01ATEX7005), or any other barrier conforming to note 5 of drawing ATX037. Entity parameters: Ui = 28 V, Ii = 93 mA, Pi = 0.65 W.

Is it suitable for surface industry (Group II)?

No. The technical data sheets certify the M2200 only for Group I (Ex ia I Ma) and do not indicate Group II certification.

Properties

FeatureSpecification
Measure and signal
Measured magnitudeVibration acceleration
ExitIsolated AC signal from constant current accelerometer
SensitivityStandard 100 mV/g ±10% at 80 Hz; optional (mV/g): I and IQ 10, 30, 50, 500 or 1000; IC and ICQ 10, 20, 25, 30, 50 or 500; IS, ISM6, ISM8, ISC, ISCM6 and ISCM8 10, 25, 30 or 50 (±10%)
Frequency response2 Hz to 10 kHz ±5% (−3 dB at 0.8 Hz)
Resonance of the mounted base18 kHz (nominal)
Dynamic range±80 g (M2200IC only)
Cross-sectional sensitivityLess than 5%
Electrical noise0.1 mg max.
Current range0.5 to 8 mA
Polarization voltage12 V DC (nominal)
ATEX/IECEx Certification
ClusterI
MarkedEx ia I Ma
CertificatesBAS02ATEX0245X and IECEx BAS 08.0013X
Ambient temperature−55 °C ≤ Ta ≤ +115 °C
Entity parametersUi = 28 V, Ii = 93 mA, Pi = 0.65 W; Ci and Li: see certificate
Food and environment
FeedingConstant current 0.5 to 8 mA with 12 V DC bias
IsolationIsolated base (isolated internal electronics to minimize noise, with greater bias voltage stability)
ProtectionIP67
Insulation testIt passes a 500V insulation test
Mechanics and connection
Housing materialStainless steel
EntranceSuperior (I, IC) or lateral (IS, ISC)
Mounting (top entry)¼"-28 UNF female thread or Q/F female quick-release base
Mounting (side entry)Bolt ¼"-28 UNF × 33 mm, M6 × 35 mm or M8 × 28 mm
Tightening torque8 Nm
Weight170g (I); 110g (IC); 140g (IS); 160g (ISC) (nominal)
Connection I and IS2-pin MS connector (military style C5015)
IC and ISC connectionIntegrated ETFE cable with stainless steel braid (5 m standard in IC)
Maximum cable lengthSee ATX037 system diagram
ReferenceConfiguration
MTN/M2200I-xx MTNM2200IXXVariant: M2200I · Connection: 2-pin MS connector (military-style C5015) · Mounting: ¼"-28 UNF female · Top input · xx = optional sensitivity 10, 30, 50, 500 or 1000 mV/g
MTN/M2200IC-xx MTNM2200ICXXVariant: M2200IC · Connection: Integrated ETFE cable with stainless steel braid · Mounting: ¼"-28 UNF female · Top entry · xx = optional sensitivity 10, 20, 25, 30, 50 or 500 mV/g
MTN/M2200ICQ-xx MTNM2200ICQXXVariant: M2200IC · Connection: Integrated ETFE cable with stainless steel braid · Mounting: Female Q/F quick-release base · Top entry · xx = optional sensitivity 10, 20, 25, 30, 50 or 500 mV/g
MTN/M2200IQ-xx MTNM2200IQXXVariant: M2200I · Connection: 2-pin MS connector (military-style C5015) · Mounting: Female Q/F quick-release base · Top input · xx = optional sensitivity 10, 30, 50, 500 or 1000 mV/g
MTN/M2200IS-xx MTNM2200ISXXVariant: M2200IS · Connection: 2-pin MS connector (military-style C5015) · Mounting: ¼"-28 UNF × 33 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)
MTN/M2200ISC-xx MTNM2200ISCXXVariant: M2200ISC · Connection: Integrated ETFE cable with stainless steel braid · Mounting: ¼"-28 UNF × 33 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)
MTN/M2200ISCM6-xx MTNM2200ISCM6XXVariant: M2200ISC · Connection: Integrated ETFE cable with stainless steel braid · Mounting: M6 × 35 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)
MTN/M2200ISCM8-xx MTNM2200ISCM8XXVariant: M2200ISC · Connection: Integrated ETFE cable with stainless steel braid · Mounting: M8 × 28 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)
MTN/M2200ISM6-xx MTNM2200ISM6XXVariant: M2200IS · Connection: 2-pin MS connector (military-style C5015) · Mounting: M6 × 35 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)
MTN/M2200ISM8-xx MTNM2200ISM8XXVariant: M2200IS · Connection: 2-pin MS connector (military-style C5015) · Mounting: M8 × 28 mm bolt · Side entry · xx = optional sensitivity 10, 25, 30, 50 mV/g (±10%)

Installation in a hazardous area

Dangerous areaSafe zoneSensorBarrierPLC / DCS4-20 mA

Entity parameters

Ui
28 V
II
93 mA
Pi
0.65 W
Ci and Li
View certificate

Barriers

MTL7728+ (BAS01ATEX7217) or P&F Z728 (BAS01ATEX7005), or any other barrier in accordance with note 5 of drawing ATX037.

Do not install in an atmosphere with high-speed airborne dust.

M2200ISC: The sheet warns that Ci and Li were previously lower and that the installer should take into account the increase in internal capacitance and inductance (the note on the sheet refers to Group II).

M2200IC: dynamic range ±80 g (the sheets of the other variants do not indicate this).

The Ci and Li parameters refer to the certificate; the sheets do not give their value.

Intrinsic safety barrier cited in the technical data sheet

MTL7728+

Eaton Zener Barrier, MTL7700 Series

Cited in the Monitran technical data sheet. Barrier data: Eaton specification sheet.

Strain
28 Vdc
Current
93 mA
Polarity
+
Barrier Installation
Zone 2
Protected circuit
You can enter zone 0
Mounting
DIN rail
Protection
IP20
Operating temperature
-20 °C to 60 °C
Dimensions
105 × 90 × 12.6 mm
Weight
140 g

Technical data sheet (PDF) Request a quote

Intrinsically safe IEPE accelerometer Monitran MTN/M2200 (ATEX/IECEx Group I)
Dimensions of the Monitran MTN/M2200I accelerometer: 51.0 mm high, Ø22.0 mm, 25 mm hexagon between faces

Other products

Monitran-Logo
4-20 mA ∝ rms speed | 0-10 to 0-100 mm/s | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, integrated cable, IP67 (IW: IP68)
Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia I Ma | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67 | Group I (mining)
Monitran-Logo
IEPE: isolated AC output, 100 mV/g ±10% | 2Hz to 10kHz ±5% | Base mounted resonance 18 kHz | Ex ia IIC, T4/T6 (IW: T6 only) | Ui 28 V · Ii 93 mA · Pi 0.65 W | Constant current 0.5 to 8 mA, 12 V DC | Stainless steel, IP67 (ISW and IW: IP68)
Monitran-Logo
4-20 mA ∝ rms acceleration | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, IP67
Monitran-Logo
IEPE: isolated AC output 100 mV/g ±10% | 2Hz to 10kHz ±5% | Base mounted resonance 18 kHz | Ex ia IIC T4/T6 Ga · Ex ia IIIC T135/T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | Constant current 0.5 to 8 mA, 12 V DC | Stainless steel, IP67 (IW and ISW: IP68)
Monitran-Logo
Output 10-100mV/g | Frequency 2Hz-10kHz | Isolated AC Output | Temperature -55 to 140°C | IP67 Protection | Stainless Steel | Top Input | Insulated Base | Power Supply 15-28V | ETFE Cable
Monitran-Logo
4-20 mA ∝ rms acceleration | 0-1 to 0-20g | 2Hz to 1kHz ±10% | Ex ia IIC T6 Ga · Ex ia IIIC T85 °C Da | Ui 28 V · Ii 93 mA · Pi 0.65 W | 12-32V DC | Stainless steel, integrated cable, IP67 (IW: IP68)