The Monitran MTN/1185 is a general-purpose vibration velocity transducer with a 4-20 mA two-wire output proportional to the RMS velocity (mm/s), for direct connection to PLCs, DCSs, and other controllers. It is ATEX and IECEx Group II intrinsically safe (Ex ia) certified for zones 0, 1, and 2 (gas) and 20, 21, and 22 (dust).
Stainless steel body with top entry and integrated cable. Two variants: 1185IC, with ETFE cable with stainless steel braid and IP67 rating, and 1185IW, with polyurethane cable, IP68 rating, and submersible up to 5 m (0.5 bar). Guemisa is an official distributor of Monitran in Spain.
Technical Frequently Asked Questions
In what areas can the Monitran MTN/1185 be installed?
In zones 0, 1 and 2 with gas (Ex ia IIC T6 Ga) and in zones 20, 21 and 22 with dust (Ex ia IIIC T85 °C Da), with an ambient temperature of −55 °C to +65 °C. Certified BAS02ATEX1057X and IECEx BAS 08.0013X, Group II.
Do you need an intrinsically safe barrier?
Yes. It connects to the PLC or control system via a barrier. The datasheets cite the MTL7787+ (BAS01ATEX7217) and the P&FZ787 (BAS01ATEX7005), or any other barrier conforming to note 4 of drawing ATX009 (1185IW: note 5 of drawing ATX031). Sensor entity parameters: Ui = 28 V, Ii = 93 mA, Pi = 0.65 W.
Is it suitable for mining?
No. The MTN/1185 is certified for Group II (surface industry), not for firedamp mines.