Accelerometer with DC response and 4-20 mA output Monitran MTN/7200
- Manufacturer: Monitran
- Category: Accelerometers and Vibration Sensors, Amplified, SENSORS
The Monitran MTN/7200 is a special-purpose, low-frequency accelerometer with a side output and output response from 0 Hz. It has a 4-20 mA bipolar output for the selected range, with 12 mA as zero g. It is powered by 10-30 V DC and responds, depending on the dynamic range (±5%), from DC up to 250 Hz (±1 g and ±2 g), 300 Hz (±5 g), 500 Hz (±10 g), 700 Hz (±20 g), and 1 kHz (±50 g).
It is manufactured entirely from compact stainless steel, IP65 rated, with an integral PVC cable featuring a stainless steel outer braid, an insulated base, and an operating temperature range of -20 to +85 °C. The series includes the MTN/7200 and MTN/7210 (four-point), MTN/7220 (single-point, 1/4" UNF), MTN/7220F (single-point, 10-32 UNF), and MTN/7220Q (single-point, Quickfit) models. Guemisa is an official distributor of Monitran in Spain.
Key points
- Bipolar 4-20 mA output for the selected range, with 12 mA as zero g, and response from DC
- Response (±5%): ±1 g and ±2 g up to 250 Hz, ±5 g up to 300 Hz, ±10 g up to 500 Hz, ±20 g up to 700 Hz and ±50 g up to 1 kHz
- Five mounting models: four small (MTN/7200) and large (MTN/7210) points, and one ¼" UNF (MTN/7220), 10-32 UNF (MTN/7220F) and Quickfit (MTN/7220Q) points
Technical Frequently Asked Questions
What output does the Monitran MTN/7200 have?
Bipolar output of 4-20 mA for the selected range, with 12 mA as zero g, and response from DC; powered by 10-30 V DC and calibration data is supplied with the sensor.
What mounting models does the MTN/7200 series have?
MTN/7200 (four point, small, requires 4 M3 screws), MTN/7210 (four point, large), MTN/7220 (one point ¼" UNF), MTN/7220F (one point 10-32 UNF) and MTN/7220Q (one point Quickfit).
What is the frequency and temperature response of the MTN/7200?
From DC up to 250 Hz in ±1 g and ±2 g, 300 Hz in ±5 g, 500 Hz in ±10 g, 700 Hz in ±20 g and 1 kHz in ±50 g (±5%); operating temperature from -20 to +85 °C.
Properties
| Feature | Specification |
|---|---|
| Measure and signal | |
| Measurement ranges | ±1, ±2, ±5, ±10, ±20 and ±50 g |
| Exit | 4-20 mA (depending on the range), bipolar, with 12 mA as zero g; calibration data supplied with the sensor |
| Frequency response | Depending on dynamic range (±5%): ±1g, DC at 250Hz; ±2 g, DC at 250 Hz; ±5g, DC at 300Hz; ±10 g, DC at 500 Hz; ±20 g, DC at 700 Hz; ±50g, DC at 1kHz |
| Resonance frequency | ±1g, 700Hz; ±2g, 700Hz; ±5g, 800Hz; ±10g, 850Hz; ±20g, 1200Hz; ±50g, 1800Hz |
| Acceleration limits | x20 in any direction |
| Electrical noise | 10 µg |
| Isolation | Isolated from the base |
| Food and environment | |
| Feeding | 10 – 30 V DC |
| Operating temperature | -20 to +85 °C |
| Storage temperature | -40 to 125 °C |
| Sealed | IP65 |
| Housing material | Stainless steel |
| Mechanics and connection | |
| Wire | PVC with stainless steel outer braid |
| Wire connection | Red: Power (+); Blue: Power (-); Screen (not connected) to the casing |
| Mounting | MTN/7200: Four-point, small (requires 4 M3 screws); MTN/7210: Four-point, large; MTN/7220: One-point 1/4" UNF; MTN/7220F: One-point 10-32 UNF; MTN/7220Q: One-point Quickfit |
| Dimensions (according to plan) | MTN/7200: 25 x Ø21 x 25; MTN/7210: Ø33.0 x 28 x 34; MTN/7220: Ø25.0 x 33 |
| Weight | 40 g (nominal) |
| Reference | Configuration |
|---|---|
| MTN/7200 MTN7200 | Mounting: four points, small · Requires 4 M3 screws MTN/7200 Technical Data Sheet (PDF) |
| MTN/7210 MTN7210 | Mounting: four points, large Technical data sheet MTN/7210 (PDF) |
| MTN/7220 MTN7220 | Mounting: one ¼" UNF dot Technical data sheet MTN/7220 (PDF) |
| MTN/7220F MTN7220F | Mounting: 10-32 UNF MTN/7220F Technical Data Sheet (PDF) |
| MTN/7220Q MTN7220Q | Assembly: One Quickfit point Technical data sheet MTN/7220Q (PDF) |