NCTE contactless magnetostrictive torque sensor: principle and data

NCTE contactless magnetostrictive torque sensor: principle and data

Technical tutorial · NCTE

Torque and force without contactReverse magnetostriction1 to 25,000 NmUp to 125 °C
Quick responseNCTE sensors measure torque and force without contact. reverse magnetostrictionThe shaft itself is magnetized with a current pulse, and a readout unit detects the change in the magnetic field at a distance of several millimeters. The standard accuracy is 0.5% to 0.2%; Standard sensors cover nominal torques from 1 to 25,000 Nm with accuracies below 0.1%.

Measurement principle: reverse magnetostriction

NCTE's contactless torque sensors are based on reverse magnetostriction: the magnetic field of an object changes due to mechanical forces. In a magnetized object, the mechanical load distorts the crystal lattice and modifies the magnetization; measuring this change yields the torque or force.

Magnetization is introduced using a patented process. The magnetic field is circular and always returns to its original orientation after deformation or vibration. A non-contact receiver detects changes in the field and evaluates them at a distance of several millimeters, even through dirt or lubricant and at high speeds.

Figure 1 · Magnetized shaft without load
Figure 1 · Magnetized shaft without load
Figure 1 · A force on the axis changes the direction of the introduced magnetization
Figure 1 · A force on the axis changes the direction of the introduced magnetization

In comparison, conventional torque sensors based on strain gauges are still suitable for very precise measurements on test benches, but their acquisition and maintenance are expensive, which prevents their use in large volumes of serial production.

Sensor construction

A non-contact torque and force sensor consists of an existing magnetized shaft (primary sensor) and a readout unit (secondary sensor) configurable according to the application. The shaft could be, for example, that of an extruder, a steering wheel, or a car transmission.

PassedOperation
1Ultrasonic cleaning and demagnetization of the shaft
2Unique introduction of magnetic fields (Pulse Current Magnetic Encoding)
3Electronics configuration, including coil placement
4Sensor calibration
5Construction with casing
FactWorth
Magnetization pulse currentA few kiloamperes, depending on the shaft diameter
Pulse durationA few milliseconds
Low field variation pairBetween 150 μT and 200 μT
Reading distanceSeveral millimeters, no contact
CalibrationJust a few seconds
Reader assembly housingNon-magnetic
Sensor calibration diagram (Kalibrierdiagram / Calibration diagram)
Sensor calibration diagram (Kalibrierdiagram / Calibration diagram)

Primary sensor material

The decisive factor for a steel to serve as a primary sensor is not its remanence or permeability, but its magnetostrictive properties. The harder the steel, the more suitable it is: it is more magnetic and exhibits less torsion, with less hysteresis after charging and discharging. Magnetic properties also depend on the material's thermal and mechanical history, so each material is examined and tested beforehand.

Steels cited as suitable
45NiCrMo16 (1.2767)
15NiCr13 (1.5752)
X20Cr13 (1.5032)
S155/300M

Features and advantages of the contactless principle

FeatureFact
Standard precision0.1% to 2%, adjustable according to application
Accuracy of standard sensorsLess than 0.1%
Nominal torques of standard sensors1 to 25,000 Nm
Speed (standard sensors)Above 10,000 rpm
Speed with externally mounted electronicsAbove 40,000 rpm
TemperatureUp to 125 °C, with continuous temperature load and externally mounted electronics
Sampling frequency in roboticsGreater than 10 kHz
Influence of oil and waterThey do not affect operations
MaintenanceIt is not required; overloading poses no risk to the sensors.
  • The existing shaft becomes the primary sensor and the secondary sensor is designed individually.
  • The measurement is performed without contact, without cables or wear.
  • The patented magnetic encoding is stable over time.
  • The original design of the axle does not need to be modified.
  • Secondary sensors save space and can be used in hollow shafts.
  • The technology is useful both in test benches and in serial applications.

The principle allows for the measurement of pressure and tension, torque and speed, and deflection (static or dynamic), and can be combined with standard speed measurement techniques or active temperature compensation.

Applications

The fields of use cited are automotive, Industry 4.0, mechanical engineering, electric bicycles, motorsports, medical technology and off-highway.

Collaborative robots

The torque-carrying shafts at each joint of the robotic arm are magnetized. By measuring on hollow shafts, these can also guide control cables and pneumatics without altering the original design. The secondary sensors are extremely compact and detect force changes at sampling frequencies above 10 kHz. They can combine torque and deflection measurements on two axes in a single sensor.

Active steering in automotive

In active steering, the existing steering shaft is magnetized, and a contactless sensor measures the torque the driver applies to the steering wheel. The electronic control unit then calculates the required assistance from the electric motor. Magnetizing the existing shaft preserves the original design and adds no weight to the steering system.

Range and durability testing

NCTE Standard Torque Sensors
NCTE Standard Torque Sensors
Essay or factResult
Load changesMore than 2 million
Temperature cycles68
Vibration120 hours
Unilateral exposure8 weeks, with no significant distortion of the measurement by hysteresis (<1%)
Optional homologation2000 Series: ATEX Zone II 3G
ATEX Mark
ATEX Mark

In addition to standard sensors, NCTE develops customized sensor solutions for each application, from the initial idea and first prototype to production, both on-demand and in series.

Frequently Asked Questions

On what principle are NCTE torque sensors based?

In reverse magnetostriction: the magnetic field of a magnetized shaft changes due to mechanical forces, and a non-contact reading unit measures that change.

How accurate are they?

Standard accuracy ranges from 0.1% to 2%, adjustable depending on the application. Standard sensors achieve accuracies of less than 0.1%.

What torque range do standard sensors cover?

Nominal torques from 1 to 25,000 Nm, with speeds exceeding 10,000 rpm.

Which steels serve as a primary sensor?

The harder the steel, the more suitable it is. Examples include 45NiCrMo16 (1.2767), 15NiCr13 (1.5752), X20Cr13 (1.5032), and S155/300M.

Is there an ATEX-approved version?

Yes, as an option for the 2000 series non-contact torque sensors, with ATEX Zone II 3G approval.